esp-open-rtos/extras/bmp180/README.md
Angus71 fd1081a0cc Added BMP180 and I2C driver and example
Fixed reference to unknown environment var
Moved drivers into extras folder and added additional documentations.
Changed LOCAL to static and renamed DEBUG to BMP180_DEBUG
2015-08-31 13:39:27 +02:00

56 lines
1.8 KiB
Markdown

# Driver for BMP085/BMP180 digital pressure sensor
This driver is written for usage with the ESP8266 and FreeRTOS ([esp-open-rtos](https://github.com/SuperHouse/esp-open-rtos) and [esp-open-rtos-driver-i2c](https://github.com/kanflo/esp-open-rtos-driver-i2c)).
### Usage
Before using the BMP180 module, the function `bmp180_init(SCL_PIN, SDA_PIN)` needs to be called to setup the I2C interface and do validation if the BMP180/BMP085 is accessible.
If the setup is sucessfully and a measurement is triggered, the result of the measurement is provided to the user as an event send via the `qQueue` provided with `bmp180_trigger_*measurement(pQueue);`
#### Example
```
#define SCL_PIN GPIO_ID_PIN(0)
#define SDA_PIN GPIO_ID_PIN(2)
...
if (!bmp180_init(SCL_PIN, SDA_PIN)) {
// An error occured, while dong the init (E.g device not found etc.)
}
// Trigger a measurement
bmp180_trigger_measurement(pQueue);
```
#### Change queue event
Per default the event send to the user via the provided queue is of the type `bmp180_result_t`. As this might not always be desired, a way is provided so that the user can provide a function, which creates and sends the event via the provided queue.
As all data aqquired from the BMP180/BMP085 is provided to the `bmp180_informUser` function, it is also possible to calculate new informations (E.g altitude etc.)
##### Example
```
// Own BMP180 User Inform Implementation
bool my_informUser(const xQueueHandle* resultQueue, uint8_t cmd, bmp180_temp_t temperatue, bmp180_press_t pressure) {
my_event_t ev;
ev.event_type = MY_EVT_BMP180;
ev.bmp180_data.cmd = cmd;
ev.bmp180_data.temperatue = temperatue;
ev.bmp180_data.pressure = pressure;
return (xQueueSend(*resultQueue, &ev, 0) == pdTRUE);
}
...
// Use our user inform implementation
// needs to be set before first measurement is triggered
bmp180_informUser = my_informUser;
```