296 lines
9.2 KiB
C
296 lines
9.2 KiB
C
/* apcsmart.h - command table for APC smart protocol units
|
|
|
|
Copyright (C) 1999 Russell Kroll <rkroll@exploits.org>
|
|
(C) 2000 Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk>
|
|
|
|
This program is free software; you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation; either version 2 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program; if not, write to the Free Software
|
|
Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
|
|
*/
|
|
|
|
#ifndef NUT_APCSMART_OLD_H_SEEN
|
|
#define NUT_APCSMART_OLD_H_SEEN 1
|
|
|
|
#include <ctype.h>
|
|
#include <sys/ioctl.h>
|
|
#include "serial.h"
|
|
#include "timehead.h"
|
|
|
|
#define APC_TABLE_VERSION "version 2.2"
|
|
|
|
/* Basic UPS reply line structure */
|
|
#define ENDCHAR 10 /* APC ends responses with LF */
|
|
|
|
/* characters ignored by default */
|
|
#define IGNCHARS "\015+$|!~%?=#&" /* special characters to ignore */
|
|
|
|
/* these one is used only during startup, due to ^Z sending certain characters such as # */
|
|
#define MINIGNCHARS "\015+$|!" /* minimum set of special characters to ignore */
|
|
|
|
/* normal polls: characters we don't want to parse (including a few alerts) */
|
|
#define POLL_IGNORE "\015&|"
|
|
|
|
/* alert characters we care about - OL, OB, LB, not LB, RB, OVER, not OVER */
|
|
#define POLL_ALERT "$!%+#?="
|
|
|
|
#define UPSDELAY 50000 /* slow down multicharacter commands */
|
|
#define CMDLONGDELAY 1500000 /* some commands need a 1.5s gap for safety */
|
|
|
|
#define SER_WAIT_SEC 3 /* wait up to 3.0 sec for ser_get calls */
|
|
#define SER_WAIT_USEC 0
|
|
|
|
/* dangerous instant commands must be reconfirmed within a 12 second window */
|
|
#define MINCMDTIME 3
|
|
#define MAXCMDTIME 15
|
|
|
|
/* it only does two strings, and they're both the same length */
|
|
#define APC_STRLEN 8
|
|
|
|
/* --------------- */
|
|
|
|
/* status bits */
|
|
|
|
#define APC_STAT_CAL 1L /* calibration */
|
|
#define APC_STAT_TRIM 2L /* SmartTrim */
|
|
#define APC_STAT_BOOST 4L /* SmartBoost */
|
|
#define APC_STAT_OL 8L /* on line */
|
|
#define APC_STAT_OB 16L /* on battery */
|
|
#define APC_STAT_OVER 32L /* overload */
|
|
#define APC_STAT_LB 64L /* low battery */
|
|
#define APC_STAT_RB 128L /* replace battery */
|
|
|
|
/* serial protocol: special commands - initialization and such */
|
|
#define APC_STATUS 'Q'
|
|
#define APC_GOSMART 'Y'
|
|
#define APC_GODUMB 'R'
|
|
#define APC_CMDSET 'a'
|
|
#define APC_CAPABILITY 26 /* ^Z */
|
|
#define APC_NEXTVAL '-'
|
|
|
|
/* --------------- */
|
|
|
|
/* Driver command table flag values */
|
|
|
|
#define APC_POLL 0x0001 /* Poll this variable regularly */
|
|
#define APC_PRESENT 0x0004 /* Capability seen on this UPS */
|
|
|
|
#define APC_RW 0x0010 /* read-write variable */
|
|
#define APC_ENUM 0x0020 /* enumerated type */
|
|
#define APC_STRING 0x0040 /* string */
|
|
|
|
#define APC_NASTY 0x0100 /* Nasty command - take care */
|
|
#define APC_REPEAT 0x0200 /* Command needs sending twice */
|
|
|
|
#define APC_FORMATMASK 0xFF0000 /* Mask for apc data formats */
|
|
|
|
#define APC_F_PERCENT 0x020000 /* Data in a percent format */
|
|
#define APC_F_VOLT 0x030000 /* Data in a voltage format */
|
|
#define APC_F_AMP 0x040000 /* Data in a current/amp format */
|
|
#define APC_F_CELSIUS 0x050000 /* Data in a temp/C format */
|
|
#define APC_F_HEX 0x060000 /* Data in a hex number format */
|
|
#define APC_F_DEC 0x070000 /* Data in a decimal format */
|
|
#define APC_F_SECONDS 0x100000 /* Time in seconds */
|
|
#define APC_F_MINUTES 0x110000 /* Time in minutes */
|
|
#define APC_F_HOURS 0x120000 /* Time in hours */
|
|
#define APC_F_REASON 0x130000 /* Reason of transfer */
|
|
#define APC_F_LEAVE 0 /* Just pass this through */
|
|
|
|
typedef struct {
|
|
const char *name; /* the variable name */
|
|
unsigned int flags; /* various flags */
|
|
unsigned char cmd; /* command character */
|
|
} apc_vartab_t;
|
|
|
|
static apc_vartab_t apc_vartab[] = {
|
|
|
|
{ "ups.firmware.old", 0, 'V' },
|
|
{ "ups.firmware", 0, 'b' },
|
|
{ "ups.firmware.aux", 0, 'v' },
|
|
{ "ups.model", 0, 0x01 },
|
|
|
|
{ "ups.serial", 0, 'n' },
|
|
{ "ups.mfr.date", 0, 'm' },
|
|
|
|
{ "ups.temperature", APC_POLL|APC_F_CELSIUS, 'C' },
|
|
{ "ups.load", APC_POLL|APC_F_PERCENT, 'P' },
|
|
|
|
{ "ups.test.interval", APC_F_HOURS, 'E' },
|
|
{ "ups.test.result", APC_POLL, 'X' },
|
|
|
|
{ "ups.delay.start", APC_F_SECONDS, 'r' },
|
|
{ "ups.delay.shutdown", APC_F_SECONDS, 'p' },
|
|
|
|
{ "ups.id", APC_STRING, 'c' },
|
|
|
|
{ "ups.contacts", APC_POLL|APC_F_HEX, 'i' },
|
|
{ "ups.display.language",
|
|
0, 0x0C },
|
|
|
|
{ "input.voltage", APC_POLL|APC_F_VOLT, 'L' },
|
|
{ "input.frequency", APC_POLL|APC_F_DEC, 'F' },
|
|
{ "input.sensitivity", 0, 's' },
|
|
{ "input.quality", APC_POLL|APC_F_HEX, '9' },
|
|
|
|
{ "input.transfer.low", APC_F_VOLT, 'l' },
|
|
{ "input.transfer.high",
|
|
APC_F_VOLT, 'u' },
|
|
{ "input.transfer.reason",
|
|
APC_POLL|APC_F_REASON, 'G' },
|
|
|
|
{ "input.voltage.maximum",
|
|
APC_POLL|APC_F_VOLT, 'M' },
|
|
{ "input.voltage.minimum",
|
|
APC_POLL|APC_F_VOLT, 'N' },
|
|
|
|
{ "output.current", APC_POLL|APC_F_AMP, '/' },
|
|
{ "output.voltage", APC_POLL|APC_F_VOLT, 'O' },
|
|
{ "output.voltage.nominal",
|
|
APC_F_VOLT, 'o' },
|
|
|
|
{ "ambient.humidity", APC_POLL|APC_F_PERCENT, 'h' },
|
|
{ "ambient.humidity.high",
|
|
APC_F_PERCENT, '{' },
|
|
{ "ambient.humidity.low",
|
|
APC_F_PERCENT, '}' },
|
|
|
|
{ "ambient.temperature",
|
|
APC_POLL|APC_F_CELSIUS, 't' },
|
|
{ "ambient.temperature.high",
|
|
APC_F_CELSIUS, '[' },
|
|
{ "ambient.temperature.low",
|
|
APC_F_CELSIUS, ']' },
|
|
|
|
{ "battery.date", APC_STRING, 'x' },
|
|
|
|
{ "battery.charge", APC_POLL|APC_F_PERCENT, 'f' },
|
|
{ "battery.charge.restart",
|
|
APC_F_PERCENT, 'e' },
|
|
|
|
{ "battery.voltage", APC_POLL|APC_F_VOLT, 'B' },
|
|
{ "battery.voltage.nominal",
|
|
0, 'g' },
|
|
|
|
{ "battery.runtime", APC_POLL|APC_F_MINUTES, 'j' },
|
|
{ "battery.runtime.low",
|
|
APC_F_MINUTES, 'q' },
|
|
|
|
{ "battery.packs", APC_F_DEC, '>' },
|
|
{ "battery.packs.bad", APC_F_DEC, '<' },
|
|
{ "battery.alarm.threshold",
|
|
0, 'k' },
|
|
/* todo:
|
|
|
|
I = alarm enable (hex field) - split into alarm.n.enable
|
|
J = alarm status (hex field) - split into alarm.n.status
|
|
|
|
0x15 = output voltage selection (APC_F_VOLT)
|
|
0x5C = load power (APC_POLL|APC_F_PERCENT)
|
|
|
|
*/
|
|
|
|
{NULL, 0, 0},
|
|
};
|
|
|
|
/* ------ instant commands ------ */
|
|
|
|
#define APC_CMD_FPTEST 'A'
|
|
#define APC_CMD_CALTOGGLE 'D'
|
|
#define APC_CMD_SHUTDOWN 'K'
|
|
#define APC_CMD_SOFTDOWN 'S'
|
|
#define APC_CMD_GRACEDOWN '@'
|
|
#define APC_CMD_SIMPWF 'U'
|
|
#define APC_CMD_BTESTTOGGLE 'W'
|
|
#define APC_CMD_OFF 'Z'
|
|
|
|
#define APC_CMD_ON 0x0E /* ^N */
|
|
#define APC_CMD_BYPTOGGLE '^'
|
|
|
|
typedef struct {
|
|
const char *name;
|
|
int flags;
|
|
unsigned char cmd;
|
|
} apc_cmdtab_t;
|
|
|
|
static apc_cmdtab_t apc_cmdtab[] =
|
|
{
|
|
{ "load.off", APC_NASTY|APC_REPEAT, APC_CMD_OFF },
|
|
{ "load.on", APC_REPEAT, APC_CMD_ON },
|
|
|
|
{ "test.panel.start", 0, APC_CMD_FPTEST },
|
|
|
|
{ "test.failure.start", 0, APC_CMD_SIMPWF },
|
|
|
|
{ "test.battery.start", 0, APC_CMD_BTESTTOGGLE },
|
|
{ "test.battery.stop", 0, APC_CMD_BTESTTOGGLE },
|
|
|
|
{ "shutdown.return.grace",
|
|
APC_NASTY, APC_CMD_GRACEDOWN },
|
|
{ "shutdown.return", APC_NASTY, APC_CMD_SOFTDOWN },
|
|
{ "shutdown.stayoff", APC_NASTY|APC_REPEAT, APC_CMD_SHUTDOWN },
|
|
|
|
{ "calibrate.start", 0, APC_CMD_CALTOGGLE },
|
|
{ "calibrate.stop", 0, APC_CMD_CALTOGGLE },
|
|
|
|
{ "bypass.start", 0, APC_CMD_BYPTOGGLE },
|
|
{ "bypass.stop", 0, APC_CMD_BYPTOGGLE },
|
|
|
|
{ NULL, 0, 0 }
|
|
};
|
|
|
|
/* compatibility with hardware that doesn't do APC_CMDSET ('a') */
|
|
|
|
static struct {
|
|
const char *firmware;
|
|
const char *cmdchars;
|
|
int flags;
|
|
} compat_tab[] = {
|
|
/* APC Matrix */
|
|
{ "0XI", "789ABCDEFGKLMNOPQRSTUVWXYZcefgjklmnopqrsuwxz/<>\\^\014\026", 0 },
|
|
{ "0XM", "789ABCDEFGKLMNOPQRSTUVWXYZcefgjklmnopqrsuwxz/<>\\^\014\026", 0 },
|
|
{ "0ZI", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 },
|
|
{ "5UI", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 },
|
|
{ "5ZM", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 },
|
|
/* APC600 */
|
|
{ "6QD", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "6QI", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "6TD", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "6TI", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
/* SmartUPS 900 */
|
|
{ "7QD", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "7QI", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "7TD", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "7TI", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
/* SmartUPS 900I */
|
|
{ "7II", "79ABCEFGKLMNOPQSUVWXYZcfg", 0 },
|
|
/* SmartUPS 2000I */
|
|
{ "9II", "79ABCEFGKLMNOPQSUVWXYZcfg", 0 },
|
|
{ "9GI", "79ABCEFGKLMNOPQSUVWXYZcfg", 0 },
|
|
/* SmartUPS 1250 */
|
|
{ "8QD", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "8QI", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "8TD", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
{ "8TI", "79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 },
|
|
/* CS 350 */
|
|
{ "5.4.D", "\1ABPQRSUYbdfgjmnx9", 0 },
|
|
/* Smart-UPS 600 */
|
|
{ "D9", "789ABCEFGKLMNOPQRSUVWXYZ", 0 },
|
|
{ "D8", "789ABCEFGKLMNOPQRSUVWXYZ", 0 },
|
|
{ "D7", "789ABCEFGKLMNOPQRSUVWXYZ", 0 },
|
|
{ "D6", "789ABCEFGKLMNOPQRSUVWXYZ", 0 },
|
|
{ "D5", "789ABCEFGKLMNOPQRSUVWXYZ", 0 },
|
|
{ "D4", "789ABCEFGKLMNOPQRSUVWXYZ", 0 },
|
|
|
|
{ NULL, NULL, 0 },
|
|
};
|
|
|
|
#endif /* NUT_APCSMART_OLD_H_SEEN */
|