/* apc-hid.c - data to monitor APC USB/HID devices with NUT
|
|
*
|
|
* Copyright (C)
|
|
* 2003 - 2009 Arnaud Quette <arnaud.quette@free.fr>
|
|
* 2005 John Stamp <kinsayder@hotmail.com>
|
|
* 2005 Peter Selinger <selinger@users.sourceforge.net>
|
|
* 2009 - 2010 Arjen de Korte <adkorte-guest@alioth.debian.org>
|
|
*
|
|
* Sponsored by MGE UPS SYSTEMS <http://www.mgeups.com>
|
|
* and Eaton <http://www.eaton.com>
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation; either version 2 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program; if not, write to the Free Software
|
|
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
|
|
*
|
|
*/
|
|
|
|
#include "main.h" /* for getval() */
|
|
#include "hidparser.h" /* for FindObject_with_ID_Node() */
|
|
#include "usbhid-ups.h"
|
|
#include "apc-hid.h"
|
|
#include "usb-common.h"
|
|
|
|
#define APC_HID_VERSION "APC HID 0.98"
|
|
|
|
/* APC */
|
|
#define APC_VENDORID 0x051d
|
|
|
|
/* Tweaks */
|
|
static char * tweak_max_report[] = {
|
|
/* Back-UPS ES 700 does NOT overflow. */
|
|
/* Back-UPS ES 725 does NOT overflow. */
|
|
/* Back-UPS ES 525 overflows on ReportID 0x0c
|
|
(UPS.PowerSummary.RemainingCapacity). */
|
|
"Back-UPS ES 525",
|
|
/* Back-UPS CS 650 overflows on ReportID 0x46 */
|
|
"Back-UPS CS",
|
|
NULL};
|
|
|
|
/* Don't use interrupt pipe on 5G models (used by proprietary protocol) */
|
|
static void *disable_interrupt_pipe(USBDevice_t *device)
|
|
{
|
|
NUT_UNUSED_VARIABLE(device);
|
|
|
|
if (use_interrupt_pipe == TRUE) {
|
|
/* FIXME? Suggest data from "device" to help the setup below? */
|
|
upslogx(LOG_INFO, "interrupt pipe disabled (add 'pollonly' flag to 'ups.conf' to get rid of this message)");
|
|
use_interrupt_pipe= FALSE;
|
|
}
|
|
return NULL;
|
|
}
|
|
|
|
/* Some models need special tweaks */
|
|
static void *general_apc_check(USBDevice_t *device)
|
|
{
|
|
int i = 0;
|
|
|
|
if (!device->Product) {
|
|
upslogx(LOG_WARNING, "device->Product is NULL so it is not possible to determine whether to activate max_report_size workaround");
|
|
return NULL;
|
|
}
|
|
|
|
/* Some models of Back-UPS overflow on some ReportID.
|
|
* This results in some data not being exposed and IO errors on
|
|
* WIN32, causing endless reconnection or driver's failure */
|
|
|
|
while( tweak_max_report[i] != NULL ) {
|
|
if(!strncmp(device->Product, tweak_max_report[i],
|
|
strlen(tweak_max_report[i]))) {
|
|
max_report_size = 1;
|
|
return NULL;
|
|
}
|
|
i++;
|
|
}
|
|
return NULL;
|
|
}
|
|
|
|
/* USB IDs device table */
|
|
static usb_device_id_t apc_usb_device_table[] = {
|
|
/* APC AP9584 Serial->USB kit */
|
|
{ USB_DEVICE(APC_VENDORID, 0x0000), NULL },
|
|
/* various models */
|
|
{ USB_DEVICE(APC_VENDORID, 0x0002), general_apc_check },
|
|
/* various 5G models */
|
|
{ USB_DEVICE(APC_VENDORID, 0x0003), disable_interrupt_pipe },
|
|
|
|
/* Terminating entry */
|
|
{ 0, 0, NULL }
|
|
};
|
|
|
|
/* returns statically allocated string - must not use it again before
|
|
done with result! */
|
|
static const char *apc_date_conversion_fun(double value)
|
|
{
|
|
static char buf[20];
|
|
int year, month, day;
|
|
|
|
if ((long)value == 0) {
|
|
return "not set";
|
|
}
|
|
|
|
/* APC apparently uses a hexadecimal-as-decimal format, e.g.,
|
|
0x102202 = October 22, 2002 */
|
|
year = ((long)value & 0xf) + 10 * (((long)value>>4) & 0xf);
|
|
month = (((long)value>>16) & 0xf) + 10 * (((long)value>>20) & 0xf);
|
|
day = (((long)value>>8) & 0xf) + 10 * (((long)value>>12) & 0xf);
|
|
|
|
/* Y2K conversion - hope that this format will be retired before 2070 :) */
|
|
if (year >= 70) {
|
|
year += 1900;
|
|
} else {
|
|
year += 2000;
|
|
}
|
|
|
|
snprintf(buf, sizeof(buf), "%04d/%02d/%02d", year, month, day);
|
|
|
|
return buf;
|
|
}
|
|
|
|
static double apc_date_conversion_reverse(const char *date_string)
|
|
{
|
|
int year, month, day;
|
|
long date;
|
|
|
|
sscanf(date_string, "%04d/%02d/%02d", &year, &month, &day);
|
|
if(year >= 2070 || month > 12 || day > 31)
|
|
return 0;
|
|
year %= 100;
|
|
date = ((year / 10 & 0x0F) << 4) + (year % 10);
|
|
date += ((month / 10 & 0x0F) << 20) + ((month % 10) << 16);
|
|
date += ((day / 10 & 0x0F) << 12) + ((day % 10) << 8);
|
|
|
|
return (double) date;
|
|
}
|
|
|
|
static info_lkp_t apc_date_conversion[] = {
|
|
{ 0, NULL, apc_date_conversion_fun, apc_date_conversion_reverse }
|
|
};
|
|
|
|
/* This was determined empirically from observing a BackUPS LS 500 */
|
|
static info_lkp_t apcstatusflag_info[] = {
|
|
{ 8, "!off", NULL, NULL }, /* Normal operation */
|
|
{ 16, "!off", NULL, NULL }, /* This occurs briefly during power-on, and corresponds to status 'DISCHRG'. */
|
|
{ 0, "off", NULL, NULL },
|
|
{ 0, NULL, NULL, NULL }
|
|
};
|
|
|
|
/* Reason of the last battery transfer (from apcupsd) */
|
|
static info_lkp_t apc_linefailcause_vrange_info[] = {
|
|
{ 1, "vrange", NULL, NULL }, /* Low line voltage */
|
|
{ 2, "vrange", NULL, NULL }, /* High line voltage */
|
|
{ 4, "vrange", NULL, NULL }, /* notch, spike, or blackout */
|
|
{ 8, "vrange", NULL, NULL }, /* Notch or blackout */
|
|
{ 9, "vrange", NULL, NULL }, /* Spike or blackout */
|
|
{ 0, "!vrange", NULL, NULL }, /* No transfers have ocurred */
|
|
{ 0, NULL, NULL, NULL }
|
|
};
|
|
|
|
static info_lkp_t apc_linefailcause_frange_info[] = {
|
|
{ 7, "frange", NULL, NULL }, /* Input frequency out of range */
|
|
{ 0, "!frange", NULL, NULL }, /* No transfers have ocurred */
|
|
{ 0, NULL, NULL, NULL }
|
|
};
|
|
|
|
#if 0
|
|
/* these input.transfer.reason can't be mapped at the moment... */
|
|
{ 3, "ripple", NULL, NULL }, /* Ripple */
|
|
{ 5, "self test", NULL, NULL }, /* Self Test or Discharge Calibration commanded
|
|
* Test usage, front button, or 2 week self test */
|
|
{ 6, "forced", NULL, NULL }, /* DelayBeforeShutdown or APCDelayBeforeShutdown */
|
|
{ 10, "forced", NULL, NULL }, /* Graceful shutdown by accessories */
|
|
{ 11, "self test", NULL, NULL }, /* Test usage invoked */
|
|
{ 12, "self test", NULL, NULL }, /* Front button initiated self test */
|
|
{ 13, "self test", NULL, NULL }, /* 2 week self test */
|
|
{ 0, NULL, NULL, NULL }
|
|
#endif
|
|
|
|
static info_lkp_t apc_sensitivity_info[] = {
|
|
{ 0, "low", NULL, NULL },
|
|
{ 1, "medium", NULL, NULL },
|
|
{ 2, "high", NULL, NULL },
|
|
{ 0, NULL, NULL, NULL }
|
|
};
|
|
|
|
/* --------------------------------------------------------------- */
|
|
/* Vendor-specific usage table */
|
|
/* --------------------------------------------------------------- */
|
|
|
|
/* APC usage table */
|
|
static usage_lkp_t apc_usage_lkp[] = {
|
|
{ "APCGeneralCollection", 0xff860005 },
|
|
{ "APCEnvironment", 0xff860006 },
|
|
{ "APCProbe1", 0xff860007 },
|
|
{ "APCProbe2", 0xff860008 },
|
|
{ "APCBattReplaceDate", 0xff860016 },
|
|
/* usage seen in dumps but unknown:
|
|
* - ff860018
|
|
* Path: UPS.Battery.ff860018, Type: Feature, ReportID: 0x48, Offset: 0, Size: 32, Value: 0
|
|
*/
|
|
{ "APCBattCapBeforeStartup", 0xff860019 }, /* FIXME: exploit */
|
|
/* usage seen in dumps but unknown:
|
|
* - ff86001a
|
|
* Path: UPS.Battery.ff86001a, Type: Input, ReportID: 0x1b, Offset: 0, Size: 8, Value: 3
|
|
* Path: UPS.Battery.ff86001a, Type: Feature, ReportID: 0x1b, Offset: 0, Size: 8, Value: 3
|
|
* - ff86001b
|
|
* Path: UPS.Battery.ff86001b, Type: Input, ReportID: 0x1c, Offset: 0, Size: 8, Value: 0
|
|
* Path: UPS.Battery.ff86001b, Type: Feature, ReportID: 0x1c, Offset: 0, Size: 8, Value: 0
|
|
* - ff860023
|
|
* Path: UPS.ff860001.ff860023, Type: Feature, ReportID: 0x60, Offset: 0, Size: 16, Value: 0
|
|
* - ff860024
|
|
* Path: UPS.Battery.ff860024, Type: Feature, ReportID: 0x47, Offset: 0, Size: 8, Value: 245
|
|
* Path: UPS.PowerConverter.ff860024, Type: Feature, ReportID: 0x51, Offset: 0, Size: 8, Value: 145
|
|
* - ff860025
|
|
* Path: UPS.ff860001.ff860025, Type: Feature, ReportID: 0x62, Offset: 0, Size: 32, Value: 0
|
|
* - ff860026
|
|
* Path: UPS.ff860001.ff860026, Type: Feature, ReportID: 0x61, Offset: 0, Size: 8, Value: 10
|
|
* - ff860027
|
|
* Path: UPS.ff860027, Type: Feature, ReportID: 0x3e, Offset: 0, Size: 32, Value: 0
|
|
* - ff860028
|
|
* Path: UPS.ff860028, Type: Feature, ReportID: 0x3f, Offset: 0, Size: 32, Value: 0
|
|
* - ff860030
|
|
* Path: UPS.Output.ff860030, Type: Feature, ReportID: 0x42, Offset: 0, Size: 16, Value: 5.8
|
|
*/
|
|
{ "APC_UPS_FirmwareRevision", 0xff860042 },
|
|
{ "APCLineFailCause", 0xff860052 },
|
|
{ "APCStatusFlag", 0xff860060 },
|
|
{ "APCSensitivity", 0xff860061 },
|
|
{ "APCPanelTest", 0xff860072 }, /* FIXME: exploit */
|
|
{ "APCShutdownAfterDelay", 0xff860076 }, /* FIXME: exploit */
|
|
{ "APC_USB_FirmwareRevision", 0xff860079 }, /* FIXME: exploit */
|
|
{ "APCDelayBeforeReboot", 0xff86007c },
|
|
{ "APCDelayBeforeShutdown", 0xff86007d },
|
|
{ "APCDelayBeforeStartup", 0xff86007e }, /* FIXME: exploit */
|
|
/* usage seen in dumps but unknown:
|
|
* - ff860080
|
|
* Path: UPS.PresentStatus.ff860080, Type: Input, ReportID: 0x33, Offset: 12, Size: 1, Value: 0
|
|
* Path: UPS.PresentStatus.ff860080, Type: Feature, ReportID: 0x33, Offset: 12, Size: 1, Value: 0
|
|
* Path: UPS.PowerSummary.PresentStatus.ff860080, Type: Input, ReportID: 0x07, Offset: 12, Size: 1, Value: 0
|
|
* Path: UPS.PowerSummary.PresentStatus.ff860080, Type: Feature, ReportID: 0x07, Offset: 12, Size: 1, Value: 0
|
|
* - ff860090, ff860091
|
|
* Path: UPS.ff860090.ff860091, Type: Feature, ReportID: 0x8c, Offset: 0, Size: 8, Value: 1.000000
|
|
* - ff860092
|
|
* Path: UPS.ff860090.ff860092, Type: Feature, ReportID: 0x8d, Offset: 0, Size: 8, Value: 25.000000
|
|
* - ff860093
|
|
* Path: UPS.ff860090.ff860093, Type: Feature, ReportID: 0x8e, Offset: 0, Size: 8, Value: 83.000000
|
|
* - ff860094
|
|
* Path: UPS.ff860090.ff860094, Type: Feature, ReportID: 0x8f, Offset: 0, Size: 8, Value: 0.000000
|
|
* - ff860095
|
|
* Path: UPS.ff860090.ff860095, Type: Feature, ReportID: 0x90, Offset: 0, Size: 8, Value: 1.000000
|
|
* - ff860096
|
|
* Path: UPS.ff860090.ff860096, Type: Feature, ReportID: 0x91, Offset: 0, Size: 16, Value: 4.000000
|
|
* - ff860097
|
|
* Path: UPS.ff860090.ff860097, Type: Feature, ReportID: 0x92, Offset: 0, Size: 16, Value: 4.000000
|
|
*/
|
|
|
|
/* Note (Arnaud): BUP stands for BackUPS Pro
|
|
* This is a HID uncompliant special (manufacturer) collection
|
|
* FIXME: these need to be used... */
|
|
{ "BUPHibernate", 0x00850058 }, /* FIXME: exploit */
|
|
{ "BUPBattCapBeforeStartup", 0x00860012 }, /* FIXME: exploit */
|
|
{ "BUPDelayBeforeStartup", 0x00860076 }, /* FIXME: exploit */
|
|
{ "BUPSelfTest", 0x00860010 }, /* FIXME: exploit */
|
|
|
|
{ NULL, 0 }
|
|
};
|
|
|
|
/*
|
|
* USB USAGE NOTES for APC (from Russell Kroll in the old hidups)
|
|
*
|
|
* FIXME: read 0xff86.... instead of 0x(00)86....?
|
|
*
|
|
* 0x860013 == 44200155090 - capability again
|
|
* == locale 4, 4 choices, 2 bytes, 00, 15, 50, 90
|
|
* == minimum charge to return online
|
|
*
|
|
* 0x860060 == "441HMLL" - looks like a 'capability' string
|
|
* == locale 4, 4 choices, 1 byte each
|
|
* == line sensitivity (high, medium, low, low)
|
|
* NOTE! the above does not seem to correspond to my info
|
|
*
|
|
* 0x860062 == D43133136127130
|
|
* == locale D, 4 choices, 3 bytes, 133, 136, 127, 130
|
|
* == high transfer voltage
|
|
*
|
|
* 0x860064 == D43103100097106
|
|
* == locale D, 4 choices, 3 bytes, 103, 100, 097, 106
|
|
* == low transfer voltage
|
|
*
|
|
* 0x860066 == 441HMLL (see 860060)
|
|
*
|
|
* 0x860074 == 4410TLN
|
|
* == locale 4, 4 choices, 1 byte, 0, T, L, N
|
|
* == alarm setting (5s, 30s, low battery, none)
|
|
*
|
|
* 0x860077 == 443060180300600
|
|
* == locale 4, 4 choices, 3 bytes, 060,180,300,600
|
|
* == wake-up delay (after power returns)
|
|
*/
|
|
|
|
static usage_tables_t apc_utab[] = {
|
|
apc_usage_lkp,
|
|
hid_usage_lkp,
|
|
NULL,
|
|
};
|
|
|
|
/* --------------------------------------------------------------- */
|
|
/* HID2NUT lookup table */
|
|
/* --------------------------------------------------------------- */
|
|
|
|
/* HID2NUT lookup table */
|
|
static hid_info_t apc_hid2nut[] = {
|
|
/* Battery page */
|
|
{ "battery.charge", 0, 0, "UPS.PowerSummary.RemainingCapacity", NULL, "%.0f", 0, NULL },
|
|
{ "battery.charge.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.RemainingCapacityLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
|
{ "battery.charge.warning", 0, 0, "UPS.PowerSummary.WarningCapacityLimit", NULL, "%.0f", 0, NULL },
|
|
{ "battery.runtime", 0, 0, "UPS.Battery.RunTimeToEmpty", NULL, "%.0f", 0, NULL },
|
|
{ "battery.runtime", 0, 0, "UPS.PowerSummary.RunTimeToEmpty", NULL, "%.0f", 0, NULL },
|
|
{ "battery.runtime.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Battery.RemainingTimeLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
|
{ "battery.runtime.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.RemainingTimeLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
|
{ "battery.voltage", 0, 0, "UPS.Battery.Voltage", NULL, "%.1f", 0, NULL },
|
|
{ "battery.voltage", 0, 0, "UPS.PowerSummary.Voltage", NULL, "%.1f", 0, NULL },
|
|
{ "battery.voltage.nominal", 0, 0, "UPS.Battery.ConfigVoltage", NULL, "%.1f", 0, NULL },
|
|
{ "battery.voltage.nominal", 0, 0, "UPS.PowerSummary.ConfigVoltage", NULL, "%.1f", 0, NULL }, /* Back-UPS 500 */
|
|
{ "battery.temperature", 0, 0, "UPS.Battery.Temperature", NULL, "%s", 0, kelvin_celsius_conversion },
|
|
{ "battery.type", 0, 0, "UPS.PowerSummary.iDeviceChemistry", NULL, "%s", 0, stringid_conversion },
|
|
{ "battery.mfr.date", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Battery.ManufacturerDate", NULL, "%s", HU_FLAG_SEMI_STATIC, date_conversion },
|
|
{ "battery.mfr.date", 0, 0, "UPS.PowerSummary.APCBattReplaceDate", NULL, "%s", 0, apc_date_conversion }, /* Back-UPS 500, Back-UPS ES/CyberFort 500 */
|
|
{ "battery.date", 0, 0, "UPS.Battery.APCBattReplaceDate", NULL, "%s", 0, apc_date_conversion }, /* Observed values: 0x0 on Back-UPS ES 650, 0x92501 on Back-UPS BF500 whose manufacture date was 2005/01/20 - this makes little sense but at least it's a valid date. */
|
|
|
|
/* UPS page */
|
|
{ "ups.load", 0, 0, "UPS.Output.PercentLoad", NULL, "%.1f", 0, NULL },
|
|
{ "ups.load", 0, 0, "UPS.PowerConverter.PercentLoad", NULL, "%.0f", 0, NULL },
|
|
/* USB HID PDC defaults */
|
|
{ "ups.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.DelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_FLAG_ABSENT, NULL},
|
|
{ "ups.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_FLAG_ABSENT, NULL},
|
|
{ "ups.timer.start", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
{ "ups.timer.shutdown", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
{ "ups.timer.reboot", 0, 0, "UPS.PowerSummary.DelayBeforeReboot", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
/* used by APC SmartUPS RM */
|
|
{ "ups.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Output.DelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_FLAG_ABSENT, NULL},
|
|
{ "ups.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Output.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_FLAG_ABSENT, NULL},
|
|
{ "ups.timer.start", 0, 0, "UPS.Output.DelayBeforeStartup", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
{ "ups.timer.shutdown", 0, 0, "UPS.Output.DelayBeforeShutdown", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
{ "ups.timer.reboot", 0, 0, "UPS.Output.DelayBeforeReboot", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
/* used by APC BackUPS ES */
|
|
{ "ups.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.APCGeneralCollection.APCDelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_FLAG_ABSENT, NULL},
|
|
{ "ups.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.APCGeneralCollection.APCDelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_FLAG_ABSENT, NULL},
|
|
{ "ups.timer.start", 0, 0, "UPS.APCGeneralCollection.APCDelayBeforeStartup", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
{ "ups.timer.shutdown", 0, 0, "UPS.APCGeneralCollection.APCDelayBeforeShutdown", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
{ "ups.timer.reboot", 0, 0, "UPS.APCGeneralCollection.APCDelayBeforeReboot", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
|
|
{ "ups.test.result", 0, 0, "UPS.Battery.Test", NULL, "%s", 0, test_read_info },
|
|
{ "ups.beeper.status", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "%s", 0, beeper_info },
|
|
{ "ups.mfr.date", 0, 0, "UPS.ManufacturerDate", NULL, "%s", 0, date_conversion },
|
|
{ "ups.mfr.date", 0, 0, "UPS.PowerSummary.ManufacturerDate", NULL, "%s", 0, date_conversion }, /* Back-UPS 500 */
|
|
{ "ups.realpower.nominal", 0, 0, "UPS.PowerConverter.ConfigActivePower", NULL, "%.0f", 0, NULL },
|
|
{ "ups.realpower.nominal", 0, 0, "UPS.Output.ConfigActivePower", NULL, "%.0f", 0, NULL },
|
|
|
|
/* the below one need to be discussed as we might need to complete
|
|
* the ups.test sub collection
|
|
* { "ups.test.panel", 0, 0, "UPS.APCPanelTest", NULL, "%.0f", 0, NULL }, */
|
|
|
|
/* Special case: ups.status & ups.alarm */
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ACPresent", NULL, NULL, HU_FLAG_QUICK_POLL, online_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Discharging", NULL, NULL, HU_FLAG_QUICK_POLL, discharging_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Charging", NULL, NULL, HU_FLAG_QUICK_POLL, charging_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ShutdownImminent", NULL, NULL, 0, shutdownimm_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit", NULL, NULL, HU_FLAG_QUICK_POLL, lowbatt_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Overload", NULL, NULL, 0, overload_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.NeedReplacement", NULL, NULL, 0, replacebatt_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.RemainingTimeLimitExpired", NULL, NULL, 0, timelimitexpired_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.BatteryPresent", NULL, NULL, 0, nobattery_info },
|
|
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.Charging", NULL, NULL, HU_FLAG_QUICK_POLL, charging_info }, /* Back-UPS 500 */
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.Discharging", NULL, NULL, HU_FLAG_QUICK_POLL, discharging_info }, /* Back-UPS 500 */
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.ACPresent", NULL, NULL, HU_FLAG_QUICK_POLL, online_info }, /* Back-UPS 500 */
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.BelowRemainingCapacityLimit", NULL, NULL, HU_FLAG_QUICK_POLL, lowbatt_info }, /* Back-UPS 500 */
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.ShutdownImminent", NULL, NULL, 0, shutdownimm_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.APCStatusFlag", NULL, NULL, HU_FLAG_QUICK_POLL, apcstatusflag_info }, /* APC Back-UPS LS 500 */
|
|
|
|
/* we map 2 times "input.transfer.reason" to be able to clear
|
|
* both vrange (voltage) and frange (frequency) */
|
|
{ "BOOL", 0, 0, "UPS.Input.APCLineFailCause", NULL, NULL, 0, apc_linefailcause_vrange_info },
|
|
{ "BOOL", 0, 0, "UPS.Input.APCLineFailCause", NULL, NULL, 0, apc_linefailcause_frange_info },
|
|
|
|
/* Input page */
|
|
{ "input.voltage", 0, 0, "UPS.Input.Voltage", NULL, "%.1f", 0, NULL },
|
|
{ "input.voltage.nominal", 0, 0, "UPS.Input.ConfigVoltage", NULL, "%.0f", 0, NULL },
|
|
{ "input.transfer.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Output.LowVoltageTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
|
{ "input.transfer.high", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Output.HighVoltageTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
|
/* used by APC BackUPS RS */
|
|
{ "input.transfer.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Input.LowVoltageTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
|
{ "input.transfer.high", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Input.HighVoltageTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
|
{ "input.sensitivity", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.Input.APCSensitivity", NULL, "%s", HU_FLAG_SEMI_STATIC, apc_sensitivity_info },
|
|
|
|
/* Output page */
|
|
{ "output.voltage", 0, 0, "UPS.Output.Voltage", NULL, "%.1f", 0, NULL },
|
|
{ "output.voltage.nominal", 0, 0, "UPS.Output.ConfigVoltage", NULL, "%.1f", 0, NULL },
|
|
{ "output.current", 0, 0, "UPS.Output.Current", NULL, "%.2f", 0, NULL },
|
|
{ "output.frequency", 0, 0, "UPS.Output.Frequency", NULL, "%.1f", 0, NULL },
|
|
|
|
/* Environmental page */
|
|
{ "ambient.temperature", 0, 0, "UPS.APCEnvironment.APCProbe1.Temperature", NULL, "%s", 0, kelvin_celsius_conversion },
|
|
{ "ambient.humidity", 0, 0, "UPS.APCEnvironment.APCProbe1.Humidity", NULL, "%.1f", 0, NULL },
|
|
/*
|
|
{ "ambient.temperature", 0, 0, "UPS.APCEnvironment.APCProbe2.Temperature", NULL, "%.1f", 0, kelvin_celsius_conversion },
|
|
{ "ambient.humidity", 0, 0, "UPS.APCEnvironment.APCProbe2.Humidity", NULL, "%.1f", 0, NULL },
|
|
*/
|
|
|
|
/* instant commands. */
|
|
/* test.* split into subset while waiting for extradata support
|
|
* ie: test.battery.start quick
|
|
*/
|
|
{ "test.battery.start.quick", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "1", HU_TYPE_CMD, NULL },
|
|
{ "test.battery.start.quick", 0, 0, "UPS.Battery.Test", NULL, "1", HU_TYPE_CMD, NULL }, /* Back-UPS RS (experimental) */
|
|
{ "test.battery.start.deep", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "2", HU_TYPE_CMD, NULL },
|
|
{ "test.battery.start.deep", 0, 0, "UPS.Battery.Test", NULL, "2", HU_TYPE_CMD, NULL }, /* Back-UPS RS (experimental) */
|
|
{ "test.battery.stop", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "3", HU_TYPE_CMD, NULL },
|
|
{ "test.battery.stop", 0, 0, "UPS.Battery.Test", NULL, "3", HU_TYPE_CMD, NULL }, /* Back-UPS RS (experimental) */
|
|
{ "test.panel.start", 0, 0, "UPS.APCPanelTest", NULL, "1", HU_TYPE_CMD, NULL },
|
|
{ "test.panel.stop", 0, 0, "UPS.APCPanelTest", NULL, "0", HU_TYPE_CMD, NULL },
|
|
{ "test.panel.start", 0, 0, "UPS.PowerSummary.APCPanelTest", NULL, "1", HU_TYPE_CMD, NULL }, /* Back-UPS 500 */
|
|
{ "test.panel.stop", 0, 0, "UPS.PowerSummary.APCPanelTest", NULL, "0", HU_TYPE_CMD, NULL }, /* Back-UPS 500 */
|
|
|
|
/* USB HID PDC defaults */
|
|
{ "load.off.delay", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_TYPE_CMD, NULL },
|
|
{ "load.on.delay", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_TYPE_CMD, NULL },
|
|
{ "shutdown.stop", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, "-1", HU_TYPE_CMD, NULL },
|
|
{ "shutdown.reboot", 0, 0, "UPS.PowerSummary.DelayBeforeReboot", NULL, "10", HU_TYPE_CMD, NULL },
|
|
/* used by APC SmartUPS RM */
|
|
{ "load.off.delay", 0, 0, "UPS.Output.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_TYPE_CMD, NULL },
|
|
{ "load.on.delay", 0, 0, "UPS.Output.DelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_TYPE_CMD, NULL },
|
|
{ "shutdown.stop", 0, 0, "UPS.Output.DelayBeforeShutdown", NULL, "-1", HU_TYPE_CMD, NULL },
|
|
{ "shutdown.reboot", 0, 0, "UPS.Output.DelayBeforeReboot", NULL, "10", HU_TYPE_CMD, NULL },
|
|
/* used by APC BackUPS ES */
|
|
{ "load.off.delay", 0, 0, "UPS.APCGeneralCollection.APCDelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_TYPE_CMD, NULL },
|
|
{ "load.on.delay", 0, 0, "UPS.APCGeneralCollection.APCDelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_TYPE_CMD, NULL },
|
|
{ "shutdown.stop", 0, 0, "UPS.APCGeneralCollection.APCDelayBeforeShutdown", NULL, "-1", HU_TYPE_CMD, NULL },
|
|
{ "shutdown.reboot", 0, 0, "UPS.APCGeneralCollection.APCDelayBeforeReboot", NULL, "10", HU_TYPE_CMD, NULL },
|
|
/* used by APC BackUPS CS */
|
|
{ "shutdown.return", 0, 0, "UPS.Output.APCDelayBeforeReboot", NULL, "1", HU_TYPE_CMD, NULL },
|
|
|
|
{ "beeper.on", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "2", HU_TYPE_CMD, NULL },
|
|
{ "beeper.off", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "3", HU_TYPE_CMD, NULL },
|
|
{ "beeper.enable", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "2", HU_TYPE_CMD, NULL },
|
|
{ "beeper.disable", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "1", HU_TYPE_CMD, NULL },
|
|
{ "beeper.mute", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "3", HU_TYPE_CMD, NULL },
|
|
|
|
/* end of structure. */
|
|
{ NULL, 0, 0, NULL, NULL, NULL, 0, NULL }
|
|
};
|
|
|
|
static const char *apc_format_model(HIDDevice_t *hd) {
|
|
static char model[64];
|
|
char *ptr1, *ptr2;
|
|
|
|
/* FIXME?: what is the path "UPS.APC_UPS_FirmwareRevision"? */
|
|
snprintf(model, sizeof(model), "%s", hd->Product ? hd->Product : "unknown");
|
|
ptr1 = strstr(model, "FW:");
|
|
if (ptr1)
|
|
{
|
|
*(ptr1 - 1) = '\0';
|
|
ptr1 += strlen("FW:");
|
|
ptr2 = strstr(ptr1, "USB FW:");
|
|
if (ptr2)
|
|
{
|
|
*(ptr2 - 1) = '\0';
|
|
ptr2 += strlen("USB FW:");
|
|
dstate_setinfo("ups.firmware.aux", "%s", ptr2);
|
|
}
|
|
dstate_setinfo("ups.firmware", "%s", ptr1);
|
|
}
|
|
return model;
|
|
}
|
|
|
|
static const char *apc_format_mfr(HIDDevice_t *hd) {
|
|
return hd->Vendor ? hd->Vendor : "APC";
|
|
}
|
|
|
|
static const char *apc_format_serial(HIDDevice_t *hd) {
|
|
return hd->Serial;
|
|
}
|
|
|
|
/* this function allows the subdriver to "claim" a device: return 1 if
|
|
* the device is supported by this subdriver, else 0. */
|
|
static int apc_claim(HIDDevice_t *hd) {
|
|
|
|
int status = is_usb_device_supported(apc_usb_device_table, hd);
|
|
|
|
switch (status) {
|
|
|
|
case POSSIBLY_SUPPORTED:
|
|
/* by default, reject, unless the productid option is given */
|
|
if (getval("productid")) {
|
|
return 1;
|
|
}
|
|
possibly_supported("APC", hd);
|
|
return 0;
|
|
|
|
case SUPPORTED:
|
|
return 1;
|
|
|
|
case NOT_SUPPORTED:
|
|
default:
|
|
return 0;
|
|
}
|
|
}
|
|
|
|
/* apc_fix_report_desc
|
|
*
|
|
* The Back-UPS XS 1400U reports incorrect logical min/max values for the
|
|
* UPS.Input.ConfigVoltage and UPS.Input.Voltage when operating in a
|
|
* 220-240V region. Detect this and fix it.
|
|
* This same fix may be applicable to other APC UPS units as well, though
|
|
* the report IDs may be different.
|
|
*/
|
|
static int apc_fix_report_desc(HIDDevice_t *pDev, HIDDesc_t *pDesc_arg) {
|
|
HIDData_t *pData;
|
|
int res = 0;
|
|
|
|
int vendorID = pDev->VendorID;
|
|
int productID = pDev->ProductID;
|
|
if (vendorID != APC_VENDORID || productID != 0x0002) {
|
|
return 0;
|
|
}
|
|
|
|
upsdebugx(3, "Attempting Report Descriptor fix for UPS: Vendor: %04x, Product: %04x", vendorID, productID);
|
|
|
|
/* Look at the High Voltage Transfer logical max value:
|
|
* If the HVT logmax is greater than the configured or input voltage limit
|
|
* then the configured/input voltage limits are probably incorrect.
|
|
* Arbitrarily set the input voltage logical min/max to 0 .. 2*HVT logmax and the
|
|
* configured (nominal) input voltage logical max to 255 (it's a single byte value)
|
|
|
|
* Path: UPS.Input.ConfigVoltage, Type: Feature, ReportID: 0x30, Offset: 0, Size: 8
|
|
* Path: UPS.Input.Voltage, Type: Feature, ReportID: 0x31, Offset: 0, Size: 16
|
|
* Path: UPS.Input.HighVoltageTransfer, Type: Feature, ReportID: 0x33, Offset: 0, Size: 16
|
|
*/
|
|
|
|
if ((pData=FindObject_with_ID_Node(pDesc_arg, 0x33, USAGE_POW_HIGH_VOLTAGE_TRANSFER))) {
|
|
long hvt_logmin = pData->LogMin;
|
|
long hvt_logmax = pData->LogMax;
|
|
upsdebugx(4, "Report Descriptor: highVoltageTransfer LogMin: %ld LogMax: %ld", hvt_logmin, hvt_logmax);
|
|
|
|
if ((pData=FindObject_with_ID_Node(pDesc_arg, 0x31, USAGE_POW_VOLTAGE))) {
|
|
long voltage_logmin = pData->LogMin;
|
|
long voltage_logmax = pData->LogMax;
|
|
upsdebugx(4, "Report Descriptor: voltage LogMin: %ld LogMax: %ld",
|
|
voltage_logmin, voltage_logmax);
|
|
|
|
if (hvt_logmax > voltage_logmax) {
|
|
pData->LogMin = 0; /* a reasonable lower limit for voltage */
|
|
pData->LogMax = hvt_logmax * 2; /* it may be smoking at this point */
|
|
upsdebugx(3, "Fixing Report Descriptor. Set voltage LogMin = %ld, LogMax = %ld",
|
|
pData->LogMin , pData->LogMax);
|
|
res = 1;
|
|
}
|
|
}
|
|
if ((pData=FindObject_with_ID_Node(pDesc_arg, 0x30, USAGE_POW_CONFIG_VOLTAGE))) {
|
|
long cvoltage_logmin = pData->LogMin;
|
|
long cvoltage_logmax = pData->LogMax;
|
|
upsdebugx(4, "Report Descriptor: configVoltage LogMin: %ld LogMax: %ld",
|
|
cvoltage_logmin, cvoltage_logmax);
|
|
|
|
if (hvt_logmax > cvoltage_logmax) {
|
|
pData->LogMax = 255;
|
|
upsdebugx(3, "Fixing Report Descriptor. Set configVoltage LogMin = %ld, LogMax = %ld",
|
|
pData->LogMin , pData->LogMax);
|
|
res = 1;
|
|
}
|
|
}
|
|
}
|
|
return res;
|
|
}
|
|
|
|
subdriver_t apc_subdriver = {
|
|
APC_HID_VERSION,
|
|
apc_claim,
|
|
apc_utab,
|
|
apc_hid2nut,
|
|
apc_format_model,
|
|
apc_format_mfr,
|
|
apc_format_serial,
|
|
apc_fix_report_desc,
|
|
};
|