# Network UPS Tools: Example upsd.users
|
|
#
|
|
# This file sets the permissions for upsd - the UPS network daemon.
|
|
# Users are defined here, are given passwords, and their privileges are
|
|
# controlled here too. Since this file will contain passwords, keep it
|
|
# secure, with only enough permissions for upsd to read it.
|
|
|
|
# --------------------------------------------------------------------------
|
|
|
|
# Each user gets a section. To start a section, put the username in
|
|
# brackets on a line by itself. To set something for that user, specify
|
|
# it under that section heading. The username is case-sensitive, so
|
|
# admin and AdMiN are two different users.
|
|
#
|
|
# Possible settings:
|
|
#
|
|
# password: The user's password. This is case-sensitive.
|
|
#
|
|
# --------------------------------------------------------------------------
|
|
#
|
|
# actions: Let the user do certain things with upsd.
|
|
#
|
|
# Valid actions are:
|
|
#
|
|
# SET - change the value of certain variables in the UPS
|
|
# FSD - set the "forced shutdown" flag in the UPS
|
|
#
|
|
# --------------------------------------------------------------------------
|
|
#
|
|
# instcmds: Let the user initiate specific instant commands. Use "ALL"
|
|
# to grant all commands automatically. There are many possible
|
|
# commands, so use 'upscmd -l' to see what your hardware supports. Here
|
|
# are a few examples:
|
|
#
|
|
# test.panel.start - Start a front panel test
|
|
# test.battery.start - Start battery test
|
|
# test.battery.stop - Stop battery test
|
|
# calibrate.start - Start calibration
|
|
# calibrate.stop - Stop calibration
|
|
#
|
|
# --------------------------------------------------------------------------
|
|
#
|
|
# Example:
|
|
#
|
|
# [admin]
|
|
# password = mypass
|
|
# actions = SET
|
|
# instcmds = ALL
|
|
#
|
|
|
|
#
|
|
# --- Configuring for upsmon
|
|
#
|
|
# To add a user for your upsmon, use this example:
|
|
#
|
|
# [upsmon]
|
|
# password = pass
|
|
# upsmon master
|
|
# or
|
|
# upsmon slave
|
|
#
|
|
# The matching MONITOR line in your upsmon.conf would look like this:
|
|
#
|
|
# MONITOR myups@localhost 1 upsmon pass master (or slave)
|