nut/drivers/bestpower-mib.c
2011-01-26 10:35:08 +01:00

80 lines
2.9 KiB
C

/* bestpower-mib.c - data to monitor Eaton Best Power Ferrups
* using earlier version of the ConnectUPS
*
* Copyright (C) 2010 - Arnaud Quette <arnaud.quette@free.fr>
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
*
*/
#include "bestpower-mib.h"
#define BESTPOWER_MIB_VERSION "0.1"
#define BESTPOWER_OID_MODEL_NAME ".1.3.6.1.4.1.2947.1.1.2.0"
/*
* http://powerquality.eaton.com/Support/Software-Drivers/Downloads/connectivity-firmware/bestpwr2.mib
*/
static info_lkp_t bestpower_power_status[] = {
{ 1, "OL" },
{ 2, "OB" },
{ 0, "NULL" }
} ;
/* Snmp2NUT lookup table for Best Power MIB */
static snmp_info_t bestpower_mib[] = {
/* Device page */
{ "device.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "ups",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
/*.1.3.6.1.4.1.2947.1.1.1.0 = STRING: "Ferrups"
.1.3.6.1.4.1.2947.1.1.2.0 = STRING: "FE850VA"*/
{ "ups.model", ST_FLAG_STRING, SU_INFOSIZE, BESTPOWER_OID_MODEL_NAME,
"Best Ferrups", SU_FLAG_STATIC, NULL, NULL },
{ "ups.serial", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.2947.1.1.5.0",
"", SU_FLAG_STATIC, NULL },
{ "ups.firmware", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.2947.1.1.7.0",
"", SU_FLAG_STATIC, NULL },
{ "ups.power", 0, 1, ".1.3.6.1.4.1.2947.1.1.3.0", "",
0, NULL },
{ "ups.mfr.date", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.2947.1.1.8.0", "",
0, NULL },
{ "ups.status", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.2947.1.2.1.0", "",
0 /*SU_STATUS_PWR*/, &bestpower_power_status[0] },
/* Battery runtime is expressed in minutes */
{ "battery.runtime", 0, 60.0, ".1.3.6.1.4.1.2947.1.2.3.0", "",
0, NULL },
/* The elapsed time in seconds since the
* UPS has switched to battery power */
{ "battery.runtime.elapsed", 0, 1.0, ".1.3.6.1.4.1.2947.1.2.2.0", "",
0, NULL },
{ "battery.voltage", 0, 0.1, ".1.3.6.1.4.1.2947.1.2.4.0", "",
0, NULL },
{ "battery.current", 0, 0.1, ".1.3.6.1.4.1.2947.1.2.5.0", "",
0, NULL },
/* end of structure. */
{ NULL, 0, 0, NULL, NULL, 0, NULL, NULL }
} ;
mib2nut_info_t bestpower = { "bestpower", BESTPOWER_MIB_VERSION, "",
BESTPOWER_OID_MODEL_NAME, bestpower_mib };