/* powerman-pdu.c - Powerman PDU client driver
|
|
*
|
|
* Copyright (C) 2008 Arnaud Quette <aquette.dev@gmail.com>
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation; either version 2 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program; if not, write to the Free Software
|
|
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
|
|
*
|
|
*/
|
|
|
|
#include "main.h"
|
|
|
|
#include <libpowerman.h>
|
|
|
|
#define DRIVER_NAME "Powerman PDU client driver"
|
|
#define DRIVER_VERSION "0.11"
|
|
|
|
/* driver description structure */
|
|
upsdrv_info_t upsdrv_info = {
|
|
DRIVER_NAME,
|
|
DRIVER_VERSION,
|
|
"Arnaud Quette <aquette.dev@gmail.com>",
|
|
DRV_EXPERIMENTAL,
|
|
{ NULL }
|
|
};
|
|
|
|
/* Powerman functions and variables */
|
|
static pm_err_t query_one(pm_handle_t pm, char *s, int mode);
|
|
static pm_err_t query_all(pm_handle_t pm, int mode);
|
|
|
|
pm_handle_t pm;
|
|
char ebuf[64];
|
|
|
|
/* modes to snmp_ups_walk. */
|
|
#define WALKMODE_INIT 0
|
|
#define WALKMODE_UPDATE 1
|
|
|
|
static int reconnect_ups(void);
|
|
|
|
static int instcmd(const char *cmdname, const char *extra)
|
|
{
|
|
pm_err_t rv = -1;
|
|
char *cmdsuffix = NULL;
|
|
char *cmdindex = NULL;
|
|
char *outletname = NULL;
|
|
|
|
upsdebugx(1, "entering instcmd (%s)", cmdname);
|
|
|
|
/* only consider the end of the command */
|
|
if ( (cmdsuffix = strrchr(cmdname, '.')) == NULL )
|
|
return STAT_INSTCMD_UNKNOWN;
|
|
else
|
|
cmdsuffix++;
|
|
|
|
/* get the outlet name */
|
|
if ( (cmdindex = strchr(cmdname, '.')) == NULL )
|
|
return STAT_INSTCMD_UNKNOWN;
|
|
else {
|
|
char buf[32];
|
|
cmdindex++;
|
|
snprintf(buf, sizeof(buf), "outlet.%i.desc", atoi(cmdindex));
|
|
outletname = (char *)dstate_getinfo(buf);
|
|
}
|
|
|
|
/* Power on the outlet */
|
|
if (!strcasecmp(cmdsuffix, "on")) {
|
|
rv = pm_node_on(pm, outletname);
|
|
return (rv==PM_ESUCCESS)?STAT_INSTCMD_HANDLED:STAT_SET_INVALID;
|
|
}
|
|
|
|
/* Power off the outlet */
|
|
if (!strcasecmp(cmdsuffix, "off")) {
|
|
rv = pm_node_off(pm, outletname);
|
|
return (rv==PM_ESUCCESS)?STAT_INSTCMD_HANDLED:STAT_SET_INVALID;
|
|
}
|
|
|
|
/* Cycle the outlet */
|
|
if (!strcasecmp(cmdsuffix, "cycle")) {
|
|
rv = pm_node_cycle(pm, outletname);
|
|
return (rv==PM_ESUCCESS)?STAT_INSTCMD_HANDLED:STAT_SET_INVALID;
|
|
}
|
|
|
|
upslogx(LOG_NOTICE, "instcmd: unknown command [%s]", cmdname);
|
|
return STAT_INSTCMD_UNKNOWN;
|
|
}
|
|
|
|
void upsdrv_updateinfo(void)
|
|
{
|
|
pm_err_t rv = PM_ESUCCESS;
|
|
|
|
if ( (rv = query_all(pm, WALKMODE_UPDATE)) != PM_ESUCCESS) {
|
|
upslogx(2, "Error: %s (%i)\n", pm_strerror(rv, ebuf, sizeof(ebuf)), errno);
|
|
/* FIXME: try to reconnect?
|
|
* dstate_datastale();
|
|
*/
|
|
reconnect_ups();
|
|
}
|
|
}
|
|
|
|
void upsdrv_initinfo(void)
|
|
{
|
|
pm_err_t rv = PM_ESUCCESS;
|
|
|
|
/* try to detect the PDU here - call fatal_with_errno(EXIT_FAILURE, ) if it fails */
|
|
|
|
/* FIXME: can we report something useful? */
|
|
dstate_setinfo("ups.mfr", "Powerman");
|
|
dstate_setinfo("device.mfr", "Powerman");
|
|
dstate_setinfo("ups.model", "unknown PDU");
|
|
dstate_setinfo("device.model", "unknown PDU");
|
|
dstate_setinfo("device.type", "pdu");
|
|
|
|
/* Now walk the data tree */
|
|
if ( (rv = query_all(pm, WALKMODE_INIT)) != PM_ESUCCESS) {
|
|
upslogx(2, "Error: %s\n", pm_strerror(rv, ebuf, sizeof(ebuf)));
|
|
/* FIXME: try to reconnect?
|
|
* dstate_datastale();
|
|
*/
|
|
reconnect_ups();
|
|
|
|
}
|
|
upsh.instcmd = instcmd;
|
|
/* FIXME: no need for setvar (ex for outlet.n.delay.*)!? */
|
|
}
|
|
|
|
void upsdrv_shutdown(void)
|
|
{
|
|
/* FIXME: shutdown all outlets? */
|
|
fatalx(EXIT_FAILURE, "shutdown not supported");
|
|
|
|
/* OL: this must power cycle the load if possible */
|
|
/* OB: the load must remain off until the power returns */
|
|
}
|
|
|
|
/*
|
|
static int setvar(const char *varname, const char *val)
|
|
{
|
|
if (!strcasecmp(varname, "outlet.n.delay.*")) {
|
|
...
|
|
return STAT_SET_HANDLED;
|
|
}
|
|
|
|
upslogx(LOG_NOTICE, "setvar: unknown variable [%s]", varname);
|
|
return STAT_SET_UNKNOWN;
|
|
}
|
|
*/
|
|
|
|
void upsdrv_help(void)
|
|
{
|
|
}
|
|
|
|
/* list flags and values that you want to receive via -x */
|
|
void upsdrv_makevartable(void)
|
|
{
|
|
/* FIXME: anything useful to be put here? */
|
|
}
|
|
|
|
void upsdrv_initups(void)
|
|
{
|
|
pm_err_t rv = PM_ESUCCESS;
|
|
|
|
/* Connect to the PowerMan daemon */
|
|
if ((rv = pm_connect(device_path, NULL, &pm, 0)) != PM_ESUCCESS) {
|
|
fatalx(EXIT_FAILURE, "Can't connect to %s: %s\n", device_path,
|
|
pm_strerror(rv, ebuf, sizeof(ebuf)));
|
|
}
|
|
|
|
/* FIXME: suitable?
|
|
* poll_interval = 30; */
|
|
}
|
|
|
|
void upsdrv_cleanup(void)
|
|
{
|
|
pm_disconnect(pm);
|
|
}
|
|
|
|
static int reconnect_ups(void)
|
|
{
|
|
pm_err_t rv;
|
|
|
|
upsdebugx(4, "==================================================");
|
|
upsdebugx(4, "= connexion lost with Powerman, try to reconnect =");
|
|
upsdebugx(4, "==================================================");
|
|
|
|
/* clear the situation */
|
|
pm_disconnect(pm);
|
|
|
|
/* Connect to the PowerMan daemon */
|
|
if ((rv = pm_connect(device_path, NULL, &pm, 0)) != PM_ESUCCESS)
|
|
return 0;
|
|
else {
|
|
upsdebugx(4, "connexion restored with Powerman");
|
|
return 1;
|
|
}
|
|
}
|
|
|
|
/*
|
|
* powerman support functions
|
|
****************************/
|
|
|
|
static pm_err_t query_one(pm_handle_t pm, char *s, int outletnum)
|
|
{
|
|
pm_err_t rv;
|
|
pm_node_state_t ns;
|
|
char outlet_prop[64];
|
|
|
|
upsdebugx(1, "entering query_one (%s)", s);
|
|
|
|
rv = pm_node_status(pm, s, &ns);
|
|
if (rv == PM_ESUCCESS) {
|
|
|
|
upsdebugx(3, "updating status");
|
|
|
|
snprintf(outlet_prop, sizeof(outlet_prop), "outlet.%i.status", outletnum);
|
|
dstate_setinfo(outlet_prop, "%s", ns == PM_ON ? "on" :
|
|
ns == PM_OFF ? "off" : "unknown");
|
|
dstate_dataok();
|
|
}
|
|
return rv;
|
|
}
|
|
|
|
static pm_err_t query_all(pm_handle_t pm, int mode)
|
|
{
|
|
pm_err_t rv;
|
|
pm_node_iterator_t itr;
|
|
char outlet_prop[64];
|
|
char *s;
|
|
int outletnum = 1;
|
|
|
|
upsdebugx(1, "entering query_all ()");
|
|
|
|
rv = pm_node_iterator_create(pm, &itr);
|
|
if (rv != PM_ESUCCESS)
|
|
return rv;
|
|
|
|
while ((s = pm_node_next(itr))) {
|
|
|
|
/* in WALKMODE_UPDATE, we always call this one for the
|
|
* status update... */
|
|
if ((rv = query_one(pm, s, outletnum)) != PM_ESUCCESS)
|
|
break;
|
|
else {
|
|
/* set the initial generic properties (ie except status)
|
|
* but only if the status query succeeded */
|
|
if (mode == WALKMODE_INIT) {
|
|
snprintf(outlet_prop, sizeof(outlet_prop), "outlet.%i.id", outletnum);
|
|
dstate_setinfo(outlet_prop, "%i", outletnum);
|
|
|
|
snprintf(outlet_prop, sizeof(outlet_prop), "outlet.%i.desc", outletnum);
|
|
dstate_setinfo(outlet_prop, "%s", s);
|
|
|
|
/* we assume it's always true! */
|
|
snprintf(outlet_prop, sizeof(outlet_prop), "outlet.%i.switchable", outletnum);
|
|
dstate_setinfo(outlet_prop, "yes");
|
|
|
|
/* add instant commands */
|
|
snprintf(outlet_prop, sizeof(outlet_prop), "outlet.%i.load.on", outletnum);
|
|
dstate_addcmd(outlet_prop);
|
|
snprintf(outlet_prop, sizeof(outlet_prop), "outlet.%i.load.off", outletnum);
|
|
dstate_addcmd(outlet_prop);
|
|
snprintf(outlet_prop, sizeof(outlet_prop), "outlet.%i.load.cycle", outletnum);
|
|
dstate_addcmd(outlet_prop);
|
|
}
|
|
}
|
|
outletnum++;
|
|
}
|
|
pm_node_iterator_destroy(itr);
|
|
return rv;
|
|
}
|