.SH "NAME"
|
|
upsset.cgi \- Web\-based UPS administration program
|
|
.SH "SYNOPSIS"
|
|
.sp
|
|
\fBupsset\&.cgi\fR
|
|
.if n \{\
|
|
.sp
|
|
.\}
|
|
.RS 4
|
|
.it 1 an-trap
|
|
.nr an-no-space-flag 1
|
|
.nr an-break-flag 1
|
|
.br
|
|
.ps +1
|
|
\fBNote\fR
|
|
.ps -1
|
|
.br
|
|
.sp
|
|
As a CGI program, this should be invoked through your web server\&. If you run it from the command line, it will sit there until you give it input resembling a POST request\&.
|
|
.sp .5v
|
|
.RE
|
|
.SH "DESCRIPTION"
|
|
.sp
|
|
\fBupsset\&.cgi\fR lets you access many administrative functions within the UPS software from your web browser\&. You can change settings and invoke instant commands where available\&.
|
|
.SH "CHANGING SETTINGS"
|
|
.sp
|
|
Some UPS hardware allows you to change certain variables to other values\&. To see what\(cqs available, pick a UPS from the chooser and select "settings", then select "View" to update the page\&.
|
|
.sp
|
|
You should see a list of items with the descriptions on the left side and the possible options or input spaces on the right\&. After changing something, be sure to "Save changes" to update the values in your UPS\&.
|
|
.sp
|
|
If your UPS doesn\(cqt support any read/write variables, there will be nothing to do on this page\&.
|
|
.sp
|
|
Setting values in read/write variables can also be done from the command line with \fBupsrw\fR(8)\&.
|
|
.SH "INSTANT COMMANDS"
|
|
.sp
|
|
Some UPS hardware also has provisions for performing certain actions at the user\(cqs command\&. These include battery tests, battery calibration, front panel tests (beep!) and more\&. To access this section, do as above, but pick "Commands" as the function\&.
|
|
.sp
|
|
If your UPS supports any instant commands, they will be listed in a chooser widget\&. Pick the one you like and "Issue command" to make it happen\&.
|
|
.if n \{\
|
|
.sp
|
|
.\}
|
|
.RS 4
|
|
.it 1 an-trap
|
|
.nr an-no-space-flag 1
|
|
.nr an-break-flag 1
|
|
.br
|
|
.ps +1
|
|
\fBNote\fR
|
|
.ps -1
|
|
.br
|
|
.sp
|
|
some dangerous commands like "Turn off load" may not happen right away\&. This is a feature, not a bug\&.
|
|
.sp .5v
|
|
.RE
|
|
.sp
|
|
The apcsmart driver and some others require that you send this command twice within a short window in order to make it happen\&. This is to keep you from accidentally killing your systems by picking the wrong one\&.
|
|
.sp
|
|
To actually turn off the load, you have to send the command once, then send it again after 3 seconds elapse but before 15 seconds pass\&. If you do it too quickly or slowly, you have to wait at least 3 seconds but not 15 seconds again\&.
|
|
.sp
|
|
You can also invoke instant commands from the command line with \fBupscmd\fR(8)\&.
|
|
.SH "ACCESS CONTROL"
|
|
.sp
|
|
upsset will only talk to \fBupsd\fR(8) servers that have been defined in your \fBhosts.conf\fR(8)\&. If it complains about "Access to that host is not authorized", check your hosts\&.conf first\&.
|
|
.SH "SECURITY"
|
|
.sp
|
|
upsset will not run until you convince it that your CGI directory has been secured\&. This is due to the possibility of someone using upsset to try password combinations against your \fBupsd\fR(8) server\&.
|
|
.sp
|
|
See the example upsset\&.conf file for more information on how you do this\&. The short explanation is\(emif you can\(cqt lock it down, don\(cqt try to run it\&.
|
|
.SH "FILES"
|
|
.sp
|
|
\fBhosts.conf\fR(5), \fBupsset.conf\fR(5)
|
|
.SH "SEE ALSO"
|
|
.SS "Internet resources:"
|
|
.sp
|
|
The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/
|