nut/docs/man/nut-recorder.8
2012-08-12 23:39:31 +02:00

103 lines
2.8 KiB
Groff

'\" t
.\" Title: nut-recorder
.\" Author: [see the "AUTHOR" section]
.\" Generator: DocBook XSL Stylesheets v1.75.2 <http://docbook.sf.net/>
.\" Date: 08/07/2012
.\" Manual: NUT Manual
.\" Source: Network UPS Tools
.\" Language: English
.\"
.TH "NUT\-RECORDER" "8" "08/07/2012" "Network UPS Tools" "NUT Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
nut-recorder \- utility to record device status and values changes
.SH "SYNOPSIS"
.sp
\fBnut\-recorder\fR \fIdevice\-name\fR [output\-file] [interval]
.SH "DESCRIPTION"
.sp
\fBnut\-recorder\fR is an utility to record device running sequence (Ie power failures or any other change) through a NUT data server, and dump it in a \&.seq format\&.
.sp
The \&.seq file can then be used by the \fBdummy-ups\fR(8) driver to replay the sequence\&.
.SH "OPTIONS"
.PP
\fIdevice\-name\fR
.RS 4
Record the changes of that device\&. The format for this option is
\fIdevname[@hostname[:port]]\fR\&. The default hostname is "localhost"\&.
.RE
.PP
\fIoutput\-file\fR
.RS 4
Optional\&. Data will be saved to this file\&. The default is
\fIdummy\-device\&.seq\fR\&.
.RE
.PP
\fIinterval\fR
.RS 4
Optional\&. The status of the device will be checked every
\fIinterval\fR\&. The default is 5 seconds\&.
.RE
.SH "EXAMPLES"
.sp
To record data from \fIups1@host1\fR every 10 seconds:
.sp
.if n \{\
.RS 4
.\}
.nf
$ nut\-recorder ups1@host1\*(Aq ups1\-output\&.seq 10
\&. \&. \&.
battery\&.charge: 100\&.0
battery\&.voltage: 13\&.9
battery\&.voltage\&.nominal: 13\&.6
ups\&.status: OL
\&. \&. \&.
battery\&.charge: 90\&.0
ups\&.status: OB
\&. \&. \&.
.fi
.if n \{\
.RE
.\}
.sp
You can then define a dummy device in \fBups.conf\fR(5):
.sp
.if n \{\
.RS 4
.\}
.nf
[ups\-test]
driver = dummy\-ups
port = ups1\-output\&.seq
.fi
.if n \{\
.RE
.\}
.SH "AUTHOR"
.sp
Arnaud Quette
.SH "SEE ALSO"
.sp
\fBdummy-ups\fR(8)
.SH "INTERNET RESOURCES"
.sp
The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/