RICHCOMM_USB(8)
|
|
===============
|
|
|
|
NAME
|
|
----
|
|
richcomm_usb - Driver UPS equipment using Richcomm dry-contact to USB
|
|
solution
|
|
|
|
NOTE
|
|
----
|
|
This man page only documents the specific features of the richcomm_usb
|
|
driver. For information about the core driver, see linkman:nutupsdrv[8].
|
|
|
|
SUPPORTED HARDWARE
|
|
------------------
|
|
The Richcomm dry-contact to USB solution is a generic interface that is
|
|
used to upgrade an existing (RS-232) contact closure UPS interface to USB.
|
|
As such, all the limitations of the underlying contact closure interface
|
|
apply. This means that you will only get the essentials in ups.status: OL,
|
|
OB, and LB. See also linkman:genericups[8].
|
|
|
|
BUGS
|
|
----
|
|
Most contact-closure UPSes will not power down the load if the line power
|
|
is present. This can create a race when using slave linkman:upsmon[8]
|
|
systems. See the linkman:upsmon[8] man page for more information.
|
|
|
|
The solution to both of these problems is to upgrade to a smart protocol
|
|
UPS of some kind that allows detection and proper load cycling on command.
|
|
|
|
AUTHORS
|
|
-------
|
|
|
|
Peter van Valderen <p.v.valderen at probu.nl>,
|
|
Dirk Teurlings <dirk at upexia.nl>
|
|
|
|
SEE ALSO
|
|
--------
|
|
|
|
The core driver:
|
|
~~~~~~~~~~~~~~~~
|
|
linkman:nutupsdrv[8]
|
|
|
|
The generic serial driver:
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
linkman:genericups[8]
|
|
|
|
Internet resources:
|
|
~~~~~~~~~~~~~~~~~~~
|
|
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|