UPSCLI_READLINE(3)
==================
NAME
----
upscli_readline, upscli_readline_timeout - read a single response from a UPS
SYNOPSIS
--------
#include <upsclient.h>
#include <time.h> /* or <sys/time.h> on some platforms */
int upscli_readline(UPSCONN_t *ups, char *buf, size_t buflen);
int upscli_readline_timeout(UPSCONN_t *ups, char *buf, size_t buflen,
const time_t timeout);
DESCRIPTION
-----------
The *upscli_readline()* and *upscli_readline_timeout()* functions take
the pointer 'ups' to a `UPSCONN_t` state structure, receive a single
line from the server, and copy up to 'buflen' bytes of the response
into the buffer 'buf'.
Some parsing of the string occurs during reception. In particular,
ERR messages from linkman:upsd[8] are detected and will cause this
function to return -1.
The difference between the two functions is that *upscli_readline_timeout()*
lets the caller decide the amount of time ('timeout' seconds) after which it
should give up and return, whereas *upscli_readline()* does not offer this
freedom, and uses NUT default network timeout (5 seconds).
RETURN VALUE
------------
The *upscli_readline()* and *upscli_readline_timeout()* functions
return 0 on success, or -1 if an error occurs.
SEE ALSO
--------
linkman:upscli_fd[3], linkman:upscli_get[3],
linkman:upscli_readline[3], linkman:upscli_sendline[3],
linkman:upscli_ssl[3],
linkman:upscli_strerror[3], linkman:upscli_upserror[3]