nut/drivers/mge-hid.c
2016-07-18 02:11:41 +02:00

1481 lines
60 KiB
C
Raw Permalink Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

/* mge-hid.c - data to monitor Eaton / MGE HID (USB and serial) devices
*
* Copyright (C)
* 2003 - 2015 Arnaud Quette <arnaud.quette@free.fr>
* 2015 Arnaud Quette <ArnaudQuette@Eaton.com>
*
* Sponsored by MGE UPS SYSTEMS <http://www.mgeups.com>
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
*
*/
/* TODO list:
* - better processing of FW info:
* * some models (HP R5000) include firmware.aux (00.01.0021;00.01.00)
* * other (9130) need more processing (0128 => 1.28)
* ...
* - better handling of input.transfer.* (need dstate_addrange)
* - outlet management logic (Ie, for outlet.X.load.{on,off}.delay
* => use outlet.X.delay.{start,stop}
*/
#include "main.h" /* for getval() */
#include "usbhid-ups.h"
#include "mge-hid.h"
#define MGE_HID_VERSION "MGE HID 1.39"
/* (prev. MGE Office Protection Systems, prev. MGE UPS SYSTEMS) */
/* Eaton */
#define MGE_VENDORID 0x0463
/* Dell */
#define DELL_VENDORID 0x047c
/* Powerware */
#define POWERWARE_VENDORID 0x0592
/* Hewlett Packard */
#define HP_VENDORID 0x03f0
/* AEG */
#define AEG_VENDORID 0x2b2d
#ifndef SHUT_MODE
#include "usb-common.h"
/* USB IDs device table */
static usb_device_id_t mge_usb_device_table[] = {
/* various models */
{ USB_DEVICE(MGE_VENDORID, 0x0001), NULL },
{ USB_DEVICE(MGE_VENDORID, 0xffff), NULL },
/* various models */
{ USB_DEVICE(DELL_VENDORID, 0xffff), NULL },
/* PW 9140 */
{ USB_DEVICE(POWERWARE_VENDORID, 0x0004), NULL },
/* R/T3000 */
{ USB_DEVICE(HP_VENDORID, 0x1fe5), NULL },
/* R/T3000 */
{ USB_DEVICE(HP_VENDORID, 0x1fe6), NULL },
/* various models */
{ USB_DEVICE(HP_VENDORID, 0x1fe7), NULL },
{ USB_DEVICE(HP_VENDORID, 0x1fe8), NULL },
/* PROTECT B / NAS */
{ USB_DEVICE(AEG_VENDORID, 0xffff), NULL },
/* Terminating entry */
{ -1, -1, NULL }
};
#endif
typedef enum {
MGE_DEFAULT_OFFLINE = 0,
MGE_PEGASUS = 0x100,
MGE_3S = 0x110,
/* All offline models have type value < 200! */
MGE_DEFAULT = 0x200, /* for line-interactive and online models */
MGE_EVOLUTION = 0x300, /* MGE Evolution series */
MGE_EVOLUTION_650,
MGE_EVOLUTION_850,
MGE_EVOLUTION_1150,
MGE_EVOLUTION_S_1250,
MGE_EVOLUTION_1550,
MGE_EVOLUTION_S_1750,
MGE_EVOLUTION_2000,
MGE_EVOLUTION_S_2500,
MGE_EVOLUTION_S_3000,
MGE_PULSAR_M = 0x400, /* MGE Pulsar M series */
MGE_PULSAR_M_2200,
MGE_PULSAR_M_3000,
MGE_PULSAR_M_3000_XL,
EATON_5P = 0x500 /* Eaton 5P / 5PX series */
} models_type_t;
/* Default to line-interactive or online (ie, not offline).
* This is then overriden for offline, through mge_model_names */
static models_type_t mge_type = MGE_DEFAULT;
/* Countries definition, for region specific settings and features */
typedef enum {
COUNTRY_UNKNOWN = -1,
COUNTRY_EUROPE = 0,
COUNTRY_US,
/* Special European models, which also supports 200 / 208 V */
COUNTRY_EUROPE_208,
COUNTRY_WORLDWIDE,
COUNTRY_AUSTRALIA,
} country_code_t;
static int country_code = COUNTRY_UNKNOWN;
static char mge_scratch_buf[20];
/* ABM - Advanced Battery Monitoring
***********************************
* Synthesis table
* HID data | Charger in ABM mode | Charger in Constant mode
* UPS.BatterySystem.Charger.ABMEnable | 1 | 0
* UPS.PowerSummary.PresentStatus.ACPresent | On utility | On battery | On utility | On battery
* Charger ABM mode | Charging | Floating | Resting | Discharging | Disabled | Disabled
* UPS.BatterySystem.Charger.Mode | 1 | 3 | 4 | 2 | 6 | 6
* UPS.PowerSummary.PresentStatus.Charging | 1 | 1 | 1 | 0 | 1 | 0
* UPS.PowerSummary.PresentStatus.Discharging | 0 |  0 |  0 | 1 | 0 | 1
*
* Notes (from David G. Miller) to understand ABM status:
* When supporting ABM, when a UPS powers up or returns from battery, or
* ends the ABM rest mode, it enters charge mode.
* Some UPSs run a different charger reference voltage during charge mode
* but all the newer models should not be doing that, but basically once
* the battery voltage reaches the charger reference level (should be 2.3
* volts/cell), the charger is considered in float mode. Some UPSs will not
* annunciate float mode until the charger power starts falling from the maximum
* level indicating the battery is truly at the float voltage or in float mode.
* The %charge level is based on battery voltage and the charge mode timer
* (should be 48 hours) and some UPSs add in a value thats related to charger
* power output. So you can have UPS that enters float mode with anywhere
* from 80% or greater battery capacity.
* float mode is not important from the softwares perspective, its there to
* help determine if the charger is advancing correctly.
* So in float mode, the charger is charging the battery, so by definition you
* can assert the CHRG flag in NUT when in “float” mode or “charge” mode.
* When in “rest” mode the charger is not delivering anything to the battery,
* but it will when the ABM cycle(28 days) ends, or a battery discharge occurs
* and utility returns. This is when the ABM status should be “resting”.
* If a battery failure is detected that disables the charger, it should be
* reporting “off” in the ABM charger status.
* Of course when delivering load power from the battery, the ABM status is
* discharging.
*/
#define ABM_UNKNOWN -1
#define ABM_DISABLED 0
#define ABM_ENABLED 1
/* Internal flag to process battery status (CHRG/DISCHRG) and ABM */
static int advanced_battery_monitoring = ABM_UNKNOWN;
/* Used to store internally if ABM is enabled or not */
static const char *eaton_abm_enabled_fun(double value)
{
advanced_battery_monitoring = value;
upsdebugx(2, "ABM is %s", (advanced_battery_monitoring==1)?"enabled":"disabled");
/* Return NULL, not to get the value published! */
return NULL;
}
static info_lkp_t eaton_abm_enabled_info[] = {
{ 0, "dummy", eaton_abm_enabled_fun },
{ 0, NULL, NULL }
};
/* Note 1: This point will need more clarification! */
# if 0
/* Used to store internally if ABM is enabled or not (for legacy units) */
static const char *eaton_abm_enabled_legacy_fun(double value)
{
advanced_battery_monitoring = value;
upsdebugx(2, "ABM is %s (legacy data)", (advanced_battery_monitoring==1)?"enabled":"disabled");
/* Return NULL, not to get the value published! */
return NULL;
}
static info_lkp_t eaton_abm_enabled_legacy_info[] = {
{ 0, "dummy", eaton_abm_enabled_legacy_fun },
{ 0, NULL, NULL }
};
#endif /* if 0 */
/* Used to process ABM flags, for battery.charger.status */
static const char *eaton_abm_status_fun(double value)
{
/* Don't process if ABM is disabled */
if (advanced_battery_monitoring == ABM_DISABLED) {
/* Clear any previously published data, in case
* the user has switched off ABM */
dstate_delinfo("battery.charger.status");
return NULL;
}
upsdebugx(2, "ABM numeric status: %i", (int)value);
switch ((long)value)
{
case 1:
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "charging");
break;
case 2:
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "discharging");
break;
case 3:
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "floating");
break;
case 4:
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "resting");
break;
case 6: /* ABM Charger Disabled */
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "off");
break;
case 5: /* Undefined - ABM is not activated */
default:
/* Return NULL, not to get the value published! */
return NULL;
}
upsdebugx(2, "ABM string status: %s", mge_scratch_buf);
return mge_scratch_buf;
}
static info_lkp_t eaton_abm_status_info[] = {
{ 1, "dummy", eaton_abm_status_fun },
{ 0, NULL, NULL }
};
/* Used to process ABM flags, for ups.status (CHRG/DISCHRG/RB) */
static const char *eaton_abm_chrg_dischrg_fun(double value)
{
/* Don't process if ABM is disabled */
if (advanced_battery_monitoring == ABM_DISABLED)
return NULL;
switch ((long)value)
{
case 1: /* charging status */
case 3: /* floating status */
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "chrg");
break;
case 2:
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "dischrg");
break;
case 6: /* ABM Charger Disabled */
case 4: /* resting, nothing to publish! (?) */
case 5: /* Undefined - ABM is not activated */
default:
/* Return NULL, not to get the value published! */
return NULL;
}
upsdebugx(2, "ABM CHRG/DISCHRG legacy string status (ups.status): %s", mge_scratch_buf);
return mge_scratch_buf;
}
static info_lkp_t eaton_abm_chrg_dischrg_info[] = {
{ 1, "dummy", eaton_abm_chrg_dischrg_fun },
{ 0, NULL, NULL }
};
/* ABM also implies that standard CHRG/DISCHRG are processed according
* to weither ABM is enabled or not...
* If ABM is disabled, we publish these legacy status
* Otherwise, we don't publish on ups.status, but only battery.charger.status */
/* FIXME: we may prefer to publish the CHRG/DISCHRG status
* on battery.charger.status?! */
static const char *eaton_abm_check_dischrg_fun(double value)
{
if (advanced_battery_monitoring == ABM_DISABLED)
{
if (value == 1) {
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "dischrg");
}
else {
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "!dischrg");
}
}
else {
/* Else, ABM is enabled, we should return NULL,
* not to get the value published!
* However, clear flags that would persist in case of prior
* publication in ABM-disabled mode */
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "!dischrg");
}
return mge_scratch_buf;
}
static info_lkp_t eaton_discharging_info[] = {
{ 1, "dummy", eaton_abm_check_dischrg_fun },
{ 0, NULL, NULL }
};
static const char *eaton_abm_check_chrg_fun(double value)
{
if (advanced_battery_monitoring == ABM_DISABLED)
{
if (value == 1) {
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "chrg");
}
else {
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "!chrg");
}
}
else {
/* Else, ABM is enabled, we should return NULL,
* not to get the value published!
* However, clear flags that would persist in case of prior
* publication in ABM-disabled mode */
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s", "!chrg");
}
return mge_scratch_buf;
}
static info_lkp_t eaton_charging_info[] = {
{ 1, "dummy", eaton_abm_check_chrg_fun },
{ 0, NULL, NULL }
};
/* The HID path 'UPS.PowerSummary.Time' reports Unix time (ie the number of
* seconds since 1970-01-01 00:00:00. This has to be split between ups.date and
* ups.time */
static const char *mge_date_conversion_fun(double value)
{
time_t sec = value;
if (strftime(mge_scratch_buf, sizeof(mge_scratch_buf), "%Y/%m/%d", localtime(&sec)) == 10) {
return mge_scratch_buf;
}
upsdebugx(3, "%s: can't compute date %g", __func__, value);
return NULL;
}
static const char *mge_time_conversion_fun(double value)
{
time_t sec = value;
if (strftime(mge_scratch_buf, sizeof(mge_scratch_buf), "%H:%M:%S", localtime(&sec)) == 8) {
return mge_scratch_buf;
}
upsdebugx(3, "%s: can't compute time %g", __func__, value);
return NULL;
}
#ifdef HAVE_STRPTIME
/* Conversion back retrieve ups.time to build the full unix time */
static double mge_date_conversion_nuf(const char *value)
{
struct tm mge_tm;
/* build a full value (date) + time string */
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s %s", value, dstate_getinfo("ups.time"));
if (strptime(mge_scratch_buf, "%Y/%m/%d %H:%M:%S", &mge_tm) != NULL) {
return mktime(&mge_tm);
}
upsdebugx(3, "%s: can't compute date %s", __func__, value);
return 0;
}
/* Conversion back retrieve ups.date to build the full unix time */
static double mge_time_conversion_nuf(const char *value)
{
struct tm mge_tm;
/* build a full date + value (time) string */
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s %s", dstate_getinfo("ups.date"), value);
if (strptime(mge_scratch_buf, "%Y/%m/%d %H:%M:%S", &mge_tm) != NULL) {
return mktime(&mge_tm);
}
upsdebugx(3, "%s: can't compute time %s", __func__, value);
return 0;
}
static info_lkp_t mge_date_conversion[] = {
{ 0, NULL, mge_date_conversion_fun, mge_date_conversion_nuf }
};
static info_lkp_t mge_time_conversion[] = {
{ 0, NULL, mge_time_conversion_fun, mge_time_conversion_nuf }
};
#else
static info_lkp_t mge_date_conversion[] = {
{ 0, NULL, mge_date_conversion_fun, NULL }
};
static info_lkp_t mge_time_conversion[] = {
{ 0, NULL, mge_time_conversion_fun, NULL }
};
#endif /* HAVE_STRPTIME */
/* The HID path 'UPS.PowerSummary.ConfigVoltage' only reports
'battery.voltage.nominal' for specific UPS series. Ignore
the value for other series (default behavior). */
static const char *mge_battery_voltage_nominal_fun(double value)
{
switch (mge_type & 0xFF00) /* Ignore model byte */
{
case MGE_EVOLUTION:
if (mge_type == MGE_EVOLUTION_650) {
value = 12.0;
}
break;
case MGE_PULSAR_M:
case EATON_5P:
break;
default:
return NULL;
}
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.0f", value);
return mge_scratch_buf;
}
static info_lkp_t mge_battery_voltage_nominal[] = {
{ 0, NULL, mge_battery_voltage_nominal_fun }
};
/* The HID path 'UPS.PowerSummary.Voltage' only reports
'battery.voltage' for specific UPS series. Ignore the
value for other series (default behavior). */
static const char *mge_battery_voltage_fun(double value)
{
switch (mge_type & 0xFF00) /* Ignore model byte */
{
case MGE_EVOLUTION:
case MGE_PULSAR_M:
case EATON_5P:
break;
default:
return NULL;
}
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.1f", value);
return mge_scratch_buf;
}
static info_lkp_t mge_battery_voltage[] = {
{ 0, NULL, mge_battery_voltage_fun }
};
static const char *mge_powerfactor_conversion_fun(double value)
{
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.2f", value / 100);
return mge_scratch_buf;
}
static info_lkp_t mge_powerfactor_conversion[] = {
{ 0, NULL, mge_powerfactor_conversion_fun }
};
static const char *mge_battery_capacity_fun(double value)
{
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.2f", value / 3600);
return mge_scratch_buf;
}
static info_lkp_t mge_battery_capacity[] = {
{ 0, NULL, mge_battery_capacity_fun }
};
info_lkp_t eaton_enable_disable_info[] = {
{ 0, "disabled", NULL },
{ 1, "enabled", NULL },
{ 0, NULL, NULL }
};
static info_lkp_t mge_upstype_conversion[] = {
{ 1, "offline / line interactive", NULL },
{ 2, "online", NULL },
{ 3, "online - unitary/parallel", NULL },
{ 4, "online - parallel with hot standy", NULL },
{ 5, "online - hot standby redundancy", NULL },
{ 0, NULL, NULL }
};
static info_lkp_t mge_sensitivity_info[] = {
{ 0, "normal", NULL },
{ 1, "high", NULL },
{ 2, "low", NULL },
{ 0, NULL, NULL }
};
static info_lkp_t mge_emergency_stop[] = {
{ 1, "Emergency stop!", NULL },
{ 0, NULL, NULL }
};
static info_lkp_t mge_wiring_fault[] = {
{ 1, "Wiring fault!", NULL },
{ 0, NULL, NULL }
};
static info_lkp_t mge_config_failure[] = {
{ 1, "Fatal EEPROM fault!", NULL },
{ 0, NULL, NULL }
};
static info_lkp_t mge_inverter_volthi[] = {
{ 1, "Inverter AC voltage too high!", NULL },
{ 0, NULL, NULL }
};
static info_lkp_t mge_inverter_voltlo[] = {
{ 1, "Inverter AC voltage too low!", NULL },
{ 0, NULL, NULL }
};
static info_lkp_t mge_short_circuit[] = {
{ 1, "Output short circuit!", NULL },
{ 0, NULL, NULL }
};
info_lkp_t mge_onbatt_info[] = {
{ 1, "!online", NULL },
{ 0, "online", NULL },
{ 0, NULL, NULL }
};
/* allow limiting to ups.model = Protection Station, Ellipse Eco
* and 3S (US 750 and AUS 700 only!) */
static const char *eaton_check_pegasus_fun(double value)
{
switch (mge_type & 0xFF00) /* Ignore model byte */
{
case MGE_PEGASUS:
break;
case MGE_3S:
/* Only consider non European models */
if (country_code != COUNTRY_EUROPE)
break;
default:
return NULL;
}
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.0f", value);
return mge_scratch_buf;
}
static info_lkp_t pegasus_threshold_info[] = {
{ 10, "10", eaton_check_pegasus_fun },
{ 25, "25", eaton_check_pegasus_fun },
{ 60, "60", eaton_check_pegasus_fun },
{ 0, NULL, NULL }
};
/* allow limiting standard yes/no info (here, to enable ECO mode) to
* ups.model = Protection Station, Ellipse Eco and 3S (US 750 and AUS 700 only!)
* this allows to enable special flags used in hid_info_t entries (Ie RW) */
static const char *pegasus_yes_no_info_fun(double value)
{
switch (mge_type & 0xFF00) /* Ignore model byte */
{
case MGE_PEGASUS:
break;
case MGE_3S:
/* Only consider non European models */
if (country_code != COUNTRY_EUROPE)
break;
default:
return NULL;
}
return (value == 0) ? "no" : "yes";
}
/* Conversion back of yes/no info */
static double pegasus_yes_no_info_nuf(const char *value)
{
switch (mge_type & 0xFF00) /* Ignore model byte */
{
case MGE_PEGASUS:
break;
case MGE_3S:
/* Only consider non European models */
if (country_code != COUNTRY_EUROPE)
break;
default:
return 0;
}
if (!strncmp(value, "yes", 3))
return 1;
else
return 0;
}
info_lkp_t pegasus_yes_no_info[] = {
{ 0, "no", pegasus_yes_no_info_fun, pegasus_yes_no_info_nuf },
{ 1, "yes", pegasus_yes_no_info_fun, pegasus_yes_no_info_nuf },
{ 0, NULL, NULL }
};
/* Determine country using UPS.PowerSummary.Country.
* If not present:
* if PowerConverter.Output.Voltage >= 200 => "Europe"
* else default to "US" */
static const char *eaton_check_country_fun(double value)
{
country_code = value;
/* Return NULL, not to get the value published! */
return NULL;
}
static info_lkp_t eaton_check_country_info[] = {
{ 0, "dummy", eaton_check_country_fun },
{ 0, NULL, NULL }
};
/* Limit nominal output voltage according to HV or LV models */
static const char *nominal_output_voltage_fun(double value)
{
static long nominal = -1;
if (nominal < 0) {
nominal = value;
}
switch ((long)nominal)
{
/* LV models */
case 100:
case 110:
case 120:
case 127:
switch ((long)value)
{
case 100:
case 110:
case 120:
case 127:
break;
default:
return NULL;
}
break;
/* line-interactive and online support 200/208 and 220/230/240*/
/* HV models */
/* 208V */
case 200:
case 208:
switch ((long)value)
{
case 200:
case 208:
break;
/* 230V */
case 220:
case 230:
case 240:
if ((mge_type & 0xFF00) >= MGE_DEFAULT)
break;
default:
return NULL;
}
break;
/* HV models */
/* 230V */
case 220:
case 230:
case 240:
switch ((long)value)
{
case 200:
case 208:
/* line-interactive and online also support 200 / 208 V
* So break on offline models */
if ((mge_type & 0xFF00) < MGE_DEFAULT)
return NULL;
/* FIXME: Some European models ("5130 RT 3000") also
* support both HV values */
if (country_code == COUNTRY_EUROPE_208)
break;
case 220:
case 230:
case 240:
break;
default:
return NULL;
}
break;
default:
upsdebugx(3, "%s: can't autodetect settable voltages from %g", __func__, value);
}
snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.0f", value);
return mge_scratch_buf;
}
static info_lkp_t nominal_output_voltage_info[] = {
/* line-interactive, starting with Evolution, support both HV values */
/* HV models */
/* 208V */
{ 200, "200", nominal_output_voltage_fun },
{ 208, "208", nominal_output_voltage_fun },
/* HV models */
/* 230V */
{ 220, "220", nominal_output_voltage_fun },
{ 230, "230", nominal_output_voltage_fun },
{ 240, "240", nominal_output_voltage_fun },
/* LV models */
{ 100, "100", nominal_output_voltage_fun },
{ 110, "110", nominal_output_voltage_fun },
{ 120, "120", nominal_output_voltage_fun },
{ 127, "127", nominal_output_voltage_fun },
{ 0, NULL, NULL }
};
/* --------------------------------------------------------------- */
/* Vendor-specific usage table */
/* --------------------------------------------------------------- */
/* Eaton / MGE HID usage table */
static usage_lkp_t mge_usage_lkp[] = {
{ "Undefined", 0xffff0000 },
{ "STS", 0xffff0001 },
{ "Environment", 0xffff0002 },
{ "Statistic", 0xffff0003 },
{ "StatisticSystem", 0xffff0004 },
/* 0xffff0005-0xffff000f => Reserved */
{ "Phase", 0xffff0010 },
{ "PhaseID", 0xffff0011 },
{ "Chopper", 0xffff0012 },
{ "ChopperID", 0xffff0013 },
{ "Inverter", 0xffff0014 },
{ "InverterID", 0xffff0015 },
{ "Rectifier", 0xffff0016 },
{ "RectifierID", 0xffff0017 },
{ "LCMSystem", 0xffff0018 },
{ "LCMSystemID", 0xffff0019 },
{ "LCMAlarm", 0xffff001a },
{ "LCMAlarmID", 0xffff001b },
{ "HistorySystem", 0xffff001c },
{ "HistorySystemID", 0xffff001d },
{ "Event", 0xffff001e },
{ "EventID", 0xffff001f },
{ "CircuitBreaker", 0xffff0020 },
{ "TransferForbidden", 0xffff0021 },
{ "OverallAlarm", 0xffff0022 }, /* renamed to Alarm in Eaton SW! */
{ "Dephasing", 0xffff0023 },
{ "BypassBreaker", 0xffff0024 },
{ "PowerModule", 0xffff0025 },
{ "PowerRate", 0xffff0026 },
{ "PowerSource", 0xffff0027 },
{ "CurrentPowerSource", 0xffff0028 },
{ "RedundancyLevel", 0xffff0029 },
{ "RedundancyLost", 0xffff002a },
{ "NotificationStatus", 0xffff002b },
{ "ProtectionLost", 0xffff002c },
{ "ConfigurationFailure", 0xffff002d },
{ "CompatibilityFailure", 0xffff002e },
/* 0xffff002e-0xffff003f => Reserved */
{ "SwitchType", 0xffff0040 }, /* renamed to Type in Eaton SW! */
{ "ConverterType", 0xffff0041 },
{ "FrequencyConverterMode", 0xffff0042 },
{ "AutomaticRestart", 0xffff0043 },
{ "ForcedReboot", 0xffff0044 },
{ "TestPeriod", 0xffff0045 },
{ "EnergySaving", 0xffff0046 },
{ "StartOnBattery", 0xffff0047 },
{ "Schedule", 0xffff0048 },
{ "DeepDischargeProtection", 0xffff0049 },
{ "ShortCircuit", 0xffff004a },
{ "ExtendedVoltageMode", 0xffff004b },
{ "SensitivityMode", 0xffff004c },
{ "RemainingCapacityLimitSetting", 0xffff004d },
{ "ExtendedFrequencyMode", 0xffff004e },
{ "FrequencyConverterModeSetting", 0xffff004f },
{ "LowVoltageBoostTransfer", 0xffff0050 },
{ "HighVoltageBoostTransfer", 0xffff0051 },
{ "LowVoltageBuckTransfer", 0xffff0052 },
{ "HighVoltageBuckTransfer", 0xffff0053 },
{ "OverloadTransferEnable", 0xffff0054 },
{ "OutOfToleranceTransferEnable", 0xffff0055 },
{ "ForcedTransferEnable", 0xffff0056 },
{ "LowVoltageBypassTransfer", 0xffff0057 },
{ "HighVoltageBypassTransfer", 0xffff0058 },
{ "FrequencyRangeBypassTransfer", 0xffff0059 },
{ "LowVoltageEcoTransfer", 0xffff005a },
{ "HighVoltageEcoTransfer", 0xffff005b },
{ "FrequencyRangeEcoTransfer", 0xffff005c },
{ "ShutdownTimer", 0xffff005d },
{ "StartupTimer", 0xffff005e },
{ "RestartLevel", 0xffff005f },
{ "PhaseOutOfRange", 0xffff0060 },
{ "CurrentLimitation", 0xffff0061 },
{ "ThermalOverload", 0xffff0062 },
{ "SynchroSource", 0xffff0063 },
{ "FuseFault", 0xffff0064 },
{ "ExternalProtectedTransfert", 0xffff0065 },
{ "ExternalForcedTransfert", 0xffff0066 },
{ "Compensation", 0xffff0067 },
{ "EmergencyStop", 0xffff0068 },
{ "PowerFactor", 0xffff0069 },
{ "PeakFactor", 0xffff006a },
{ "ChargerType", 0xffff006b },
{ "HighPositiveDCBusVoltage", 0xffff006c },
{ "LowPositiveDCBusVoltage", 0xffff006d },
{ "HighNegativeDCBusVoltage", 0xffff006e },
{ "LowNegativeDCBusVoltage", 0xffff006f },
{ "FrequencyRangeTransfer", 0xffff0070 },
{ "WiringFaultDetection", 0xffff0071 },
{ "ControlStandby", 0xffff0072 },
{ "ShortCircuitTolerance", 0xffff0073 },
{ "VoltageTooHigh", 0xffff0074 },
{ "VoltageTooLow", 0xffff0075 },
{ "DCBusUnbalanced", 0xffff0076 },
{ "FanFailure", 0xffff0077 },
{ "WiringFault", 0xffff0078 },
{ "Floating", 0xffff0079 },
{ "OverCurrent", 0xffff007a },
{ "RemainingActivePower", 0xffff007b },
{ "Energy", 0xffff007c },
{ "Threshold", 0xffff007d },
{ "OverThreshold", 0xffff007e },
/* 0xffff007f => Reserved */
{ "Sensor", 0xffff0080 },
{ "LowHumidity", 0xffff0081 },
{ "HighHumidity", 0xffff0082 },
{ "LowTemperature", 0xffff0083 },
{ "HighTemperature", 0xffff0084 },
{ "ECOControl", 0xffff0085 },
{ "Efficiency", 0xffff0086 },
{ "ABMEnable", 0xffff0087 },
{ "NegativeCurrent", 0xffff0088 },
{ "AutomaticStart", 0xffff0089 },
/* 0xffff008a-0xffff008f => Reserved */
{ "Count", 0xffff0090 },
{ "Timer", 0xffff0091 },
{ "Interval", 0xffff0092 },
{ "TimerExpired", 0xffff0093 },
{ "Mode", 0xffff0094 },
{ "Country", 0xffff0095 },
{ "State", 0xffff0096 },
{ "Time", 0xffff0097 },
{ "Code", 0xffff0098 },
{ "DataValid", 0xffff0099 },
{ "ToggleTimer", 0xffff009a },
{ "BypassTransferDelay", 0xffff009b },
{ "HysteresysVoltageTransfer", 0xffff009c },
{ "SlewRate", 0xffff009d },
/* 0xffff009e-0xffff009f => Reserved */
{ "PDU", 0xffff00a0 },
{ "Breaker", 0xffff00a1 },
{ "BreakerID", 0xffff00a2 },
{ "OverVoltage", 0xffff00a3 },
{ "Tripped", 0xffff00a4 },
{ "OverEnergy", 0xffff00a5 },
{ "OverHumidity", 0xffff00a6 },
{ "ConfigurationReset", 0xffff00a7 }, /* renamed from LCDControl in Eaton SW! */
{ "Level", 0xffff00a8 },
{ "PDUType", 0xffff00a9 },
{ "ReactivePower", 0xffff00aa },
{ "Pole", 0xffff00ab },
{ "PoleID", 0xffff00ac },
{ "Reset", 0xffff00ad },
{ "WatchdogReset", 0xffff00ae },
/* 0xffff00af-0xffff00df => Reserved */
{ "COPIBridge", 0xffff00e0 },
/* 0xffff00e1-0xffff00ef => Reserved */
{ "iModel", 0xffff00f0 },
{ "iVersion", 0xffff00f1 },
{ "iTechnicalLevel", 0xffff00f2 },
{ "iPartNumber", 0xffff00f3 },
{ "iReferenceNumber", 0xffff00f4 },
{ "iGang", 0xffff00f5 },
/* 0xffff00f6-0xffff00ff => Reserved */
/* end of table */
{ NULL, 0 }
};
static usage_tables_t mge_utab[] = {
mge_usage_lkp,
hid_usage_lkp,
NULL,
};
/* --------------------------------------------------------------- */
/* Model Name formating entries */
/* --------------------------------------------------------------- */
typedef struct {
const char *iProduct;
const char *iModel;
models_type_t type; /* enumerated model type */
const char *name; /* optional (defaults to "<iProduct> <iModel>" if NULL) */
} models_name_t;
/*
* Do not remove models from this list, but instead comment them
* out if not needed. This allows us to quickly add overrides for
* specific models only, should this be needed.
*/
static models_name_t mge_model_names [] =
{
/* Ellipse models */
{ "ELLIPSE", "300", MGE_DEFAULT_OFFLINE, "ellipse 300" },
{ "ELLIPSE", "500", MGE_DEFAULT_OFFLINE, "ellipse 500" },
{ "ELLIPSE", "650", MGE_DEFAULT_OFFLINE, "ellipse 650" },
{ "ELLIPSE", "800", MGE_DEFAULT_OFFLINE, "ellipse 800" },
{ "ELLIPSE", "1200", MGE_DEFAULT_OFFLINE, "ellipse 1200" },
/* Ellipse Premium models */
{ "ellipse", "PR500", MGE_DEFAULT_OFFLINE, "ellipse premium 500" },
{ "ellipse", "PR650", MGE_DEFAULT_OFFLINE, "ellipse premium 650" },
{ "ellipse", "PR800", MGE_DEFAULT_OFFLINE, "ellipse premium 800" },
{ "ellipse", "PR1200", MGE_DEFAULT_OFFLINE, "ellipse premium 1200" },
/* Ellipse "Pro" */
{ "ELLIPSE", "600", MGE_DEFAULT_OFFLINE, "Ellipse 600" },
{ "ELLIPSE", "750", MGE_DEFAULT_OFFLINE, "Ellipse 750" },
{ "ELLIPSE", "1000", MGE_DEFAULT_OFFLINE, "Ellipse 1000" },
{ "ELLIPSE", "1500", MGE_DEFAULT_OFFLINE, "Ellipse 1500" },
/* Ellipse MAX */
{ "Ellipse MAX", "600", MGE_DEFAULT_OFFLINE, NULL },
{ "Ellipse MAX", "850", MGE_DEFAULT_OFFLINE, NULL },
{ "Ellipse MAX", "1100", MGE_DEFAULT_OFFLINE, NULL },
{ "Ellipse MAX", "1500", MGE_DEFAULT_OFFLINE, NULL },
/* Protection Center */
{ "PROTECTIONCENTER", "420", MGE_DEFAULT_OFFLINE, "Protection Center 420" },
{ "PROTECTIONCENTER", "500", MGE_DEFAULT_OFFLINE, "Protection Center 500" },
{ "PROTECTIONCENTER", "675", MGE_DEFAULT_OFFLINE, "Protection Center 675" },
/* Protection Station, supports Eco control */
{ "Protection Station", "500", MGE_PEGASUS, NULL },
{ "Protection Station", "650", MGE_PEGASUS, NULL },
{ "Protection Station", "800", MGE_PEGASUS, NULL },
/* Ellipse ECO, also supports Eco control */
{ "Ellipse ECO", "650", MGE_PEGASUS, NULL },
{ "Ellipse ECO", "800", MGE_PEGASUS, NULL },
{ "Ellipse ECO", "1200", MGE_PEGASUS, NULL },
{ "Ellipse ECO", "1600", MGE_PEGASUS, NULL },
/* 3S, also supports Eco control on some models (AUS 700 and US 750)*/
{ "3S", "450", MGE_DEFAULT_OFFLINE, NULL }, /* US only */
{ "3S", "550", MGE_DEFAULT_OFFLINE, NULL }, /* US 120V + EU 230V + AUS 240V */
{ "3S", "700", MGE_3S, NULL }, /* EU 230V + AUS 240V (w/ eco control) */
{ "3S", "750", MGE_3S, NULL }, /* US 120V (w/ eco control) */
/* Evolution models */
{ "Evolution", "500", MGE_DEFAULT, "Pulsar Evolution 500" },
{ "Evolution", "800", MGE_DEFAULT, "Pulsar Evolution 800" },
{ "Evolution", "1100", MGE_DEFAULT, "Pulsar Evolution 1100" },
{ "Evolution", "1500", MGE_DEFAULT, "Pulsar Evolution 1500" },
{ "Evolution", "2200", MGE_DEFAULT, "Pulsar Evolution 2200" },
{ "Evolution", "3000", MGE_DEFAULT, "Pulsar Evolution 3000" },
{ "Evolution", "3000XL", MGE_DEFAULT, "Pulsar Evolution 3000 XL" },
/* Newer Evolution models */
{ "Evolution", "650", MGE_EVOLUTION_650, NULL },
{ "Evolution", "850", MGE_EVOLUTION_850, NULL },
{ "Evolution", "1150", MGE_EVOLUTION_1150, NULL },
{ "Evolution", "S 1250", MGE_EVOLUTION_S_1250, NULL },
{ "Evolution", "1550", MGE_EVOLUTION_1550, NULL },
{ "Evolution", "S 1750", MGE_EVOLUTION_S_1750, NULL },
{ "Evolution", "2000", MGE_EVOLUTION_2000, NULL },
{ "Evolution", "S 2500", MGE_EVOLUTION_S_2500, NULL },
{ "Evolution", "S 3000", MGE_EVOLUTION_S_3000, NULL },
/* Eaton 5P */
{ "Eaton 5P", "650", EATON_5P, "5P 650" },
{ "Eaton 5P", "850", EATON_5P, "5P 850" },
{ "Eaton 5P", "1150", EATON_5P, "5P 1150" },
{ "Eaton 5P", "1550", EATON_5P, "5P 1550" },
/* Pulsar M models */
{ "PULSAR M", "2200", MGE_PULSAR_M_2200, NULL },
{ "PULSAR M", "3000", MGE_PULSAR_M_3000, NULL },
{ "PULSAR M", "3000 XL", MGE_PULSAR_M_3000_XL, NULL },
/* Eaton'ified names */
{ "EX", "2200", MGE_PULSAR_M_2200, NULL },
{ "EX", "3000", MGE_PULSAR_M_3000, NULL },
{ "EX", "3000 XL", MGE_PULSAR_M_3000, NULL },
/* Pulsar models (TBR) */
/* { "Pulsar", "700", MGE_DEFAULT, NULL }, */
/* { "Pulsar", "1000", MGE_DEFAULT, NULL }, */
/* { "Pulsar", "1500", MGE_DEFAULT, NULL }, */
/* { "Pulsar", "1000 RT2U", MGE_DEFAULT, NULL }, */
/* { "Pulsar", "1500 RT2U", MGE_DEFAULT, NULL }, */
/* Eaton'ified names (TBR) */
/* { "EX", "700", MGE_DEFAULT, NULL }, */
/* { "EX", "1000", MGE_DEFAULT, NULL }, */
/* { "EX", "1500", MGE_DEFAULT, NULL }, */
/* { "EX", "1000 RT2U", MGE_DEFAULT, NULL }, */
/* { "EX", "1500 RT2U", MGE_DEFAULT, NULL }, */
/* Pulsar MX models */
{ "PULSAR", "MX4000", MGE_DEFAULT, "Pulsar MX 4000 RT" },
{ "PULSAR", "MX5000", MGE_DEFAULT, "Pulsar MX 5000 RT" },
/* NOVA models */
{ "NOVA AVR", "500", MGE_DEFAULT, "Nova 500 AVR" },
{ "NOVA AVR", "600", MGE_DEFAULT, "Nova 600 AVR" },
{ "NOVA AVR", "625", MGE_DEFAULT, "Nova 625 AVR" },
{ "NOVA AVR", "1100", MGE_DEFAULT, "Nova 1100 AVR" },
{ "NOVA AVR", "1250", MGE_DEFAULT, "Nova 1250 AVR" },
/* EXtreme C (EMEA) */
{ "EXtreme", "700C", MGE_DEFAULT, "Pulsar EXtreme 700C" },
{ "EXtreme", "1000C", MGE_DEFAULT, "Pulsar EXtreme 1000C" },
{ "EXtreme", "1500C", MGE_DEFAULT, "Pulsar EXtreme 1500C" },
{ "EXtreme", "1500CCLA", MGE_DEFAULT, "Pulsar EXtreme 1500C CLA" },
{ "EXtreme", "2200C", MGE_DEFAULT, "Pulsar EXtreme 2200C" },
{ "EXtreme", "3200C", MGE_DEFAULT, "Pulsar EXtreme 3200C" },
/* EXtreme C (USA, aka "EX RT") */
{ "EX", "700RT", MGE_DEFAULT, "Pulsar EX 700 RT" },
{ "EX", "1000RT", MGE_DEFAULT, "Pulsar EX 1000 RT" },
{ "EX", "1500RT", MGE_DEFAULT, "Pulsar EX 1500 RT" },
{ "EX", "2200RT", MGE_DEFAULT, "Pulsar EX 2200 RT" },
{ "EX", "3200RT", MGE_DEFAULT, "Pulsar EX 3200 RT" },
/* Comet EX RT three phased */
{ "EX", "5RT31", MGE_DEFAULT, "EX 5 RT 3:1" },
{ "EX", "7RT31", MGE_DEFAULT, "EX 7 RT 3:1" },
{ "EX", "11RT31", MGE_DEFAULT, "EX 11 RT 3:1" },
/* Comet EX RT mono phased */
{ "EX", "5RT", MGE_DEFAULT, "EX 5 RT" },
{ "EX", "7RT", MGE_DEFAULT, "EX 7 RT" },
{ "EX", "11RT", MGE_DEFAULT, "EX 11 RT" },
/* Galaxy 3000 */
{ "GALAXY", "3000_10", MGE_DEFAULT, "Galaxy 3000 10 kVA" },
{ "GALAXY", "3000_15", MGE_DEFAULT, "Galaxy 3000 15 kVA" },
{ "GALAXY", "3000_20", MGE_DEFAULT, "Galaxy 3000 20 kVA" },
{ "GALAXY", "3000_30", MGE_DEFAULT, "Galaxy 3000 30 kVA" },
/* end of structure. */
{ NULL }
};
/* --------------------------------------------------------------- */
/* Data lookup table (HID <-> NUT) */
/* --------------------------------------------------------------- */
static hid_info_t mge_hid2nut[] =
{
/* Device collection */
/* Just declared to call *hid2info */
{ "device.country", ST_FLAG_STRING, 20, "UPS.PowerSummary.Country", NULL, "Europe", HU_FLAG_STATIC, eaton_check_country_info },
/* Battery page */
{ "battery.charge", 0, 0, "UPS.PowerSummary.RemainingCapacity", NULL, "%.0f", 0, NULL },
{ "battery.charge.low", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerSummary.RemainingCapacityLimitSetting", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "battery.charge.low", 0, 0, "UPS.PowerSummary.RemainingCapacityLimit", NULL, "%.0f", HU_FLAG_STATIC , NULL }, /* Read only */
{ "battery.charge.restart", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.PowerSummary.RestartLevel", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "battery.capacity", 0, 0, "UPS.BatterySystem.Battery.DesignCapacity", NULL, "%s", HU_FLAG_STATIC, mge_battery_capacity }, /* conversion needed from As to Ah */
{ "battery.runtime", 0, 0, "UPS.PowerSummary.RunTimeToEmpty", NULL, "%.0f", 0, NULL },
{ "battery.runtime.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.RemainingTimeLimit", NULL, "%.0f", 0, NULL },
{ "battery.runtime.elapsed", 0, 0, "UPS.StatisticSystem.Input.[1].Statistic.[1].Time", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL },
{ "battery.runtime.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.RemainingTimeLimit", NULL, "%.0f", 0, NULL },
{ "battery.temperature", 0, 0, "UPS.BatterySystem.Battery.Temperature", NULL, "%s", 0, kelvin_celsius_conversion },
{ "battery.type", 0, 0, "UPS.PowerSummary.iDeviceChemistry", NULL, "%s", HU_FLAG_STATIC, stringid_conversion },
{ "battery.voltage", 0, 0, "UPS.BatterySystem.Voltage", NULL, "%.1f", 0, NULL },
{ "battery.voltage", 0, 0, "UPS.PowerSummary.Voltage", NULL, "%s", 0, mge_battery_voltage },
{ "battery.voltage.nominal", 0, 0, "UPS.BatterySystem.ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "battery.voltage.nominal", 0, 0, "UPS.PowerSummary.ConfigVoltage", NULL, "%s", HU_FLAG_STATIC, mge_battery_voltage_nominal },
{ "battery.protection", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.BatterySystem.Battery.DeepDischargeProtection", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info },
{ "battery.energysave", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[3].EnergySaving", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info },
{ "battery.energysave.load", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[3].ConfigPercentLoad", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
/* Current implementation */
{ "battery.energysave.delay", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[3].EnergySaving.ShutdownTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
/* Newer implementation */
{ "battery.energysave.delay", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[3].ShutdownTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "battery.energysave.realpower", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[3].ConfigActivePower", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
/* ABM (Advanced Battery Monitoring) processing
* Must be processed before the BOOL status */
/* Not published, just to store in internal var. advanced_battery_monitoring */
{ "battery.charger.status", 0, 0, "UPS.BatterySystem.Charger.ABMEnable", NULL, "%.0f", HU_FLAG_QUICK_POLL, eaton_abm_enabled_info },
/* Same as the one above, but for legacy units */
/* Refer to Note 1 (This point will need more clarification!)
{ "battery.charger.status", 0, 0, "UPS.BatterySystem.Charger.PresentStatus.Used", NULL, "%.0f", HU_FLAG_QUICK_POLL, eaton_abm_enabled_legacy_info }, */
/* This data is the actual ABM status information */
{ "battery.charger.status", 0, 0, "UPS.BatterySystem.Charger.Mode", NULL, "%.0f", HU_FLAG_QUICK_POLL, eaton_abm_status_info },
/* UPS page */
{ "ups.efficiency", 0, 0, "UPS.PowerConverter.Output.Efficiency", NULL, "%.0f", 0, NULL },
{ "ups.firmware", 0, 0, "UPS.PowerSummary.iVersion", NULL, "%s", HU_FLAG_STATIC, stringid_conversion },
{ "ups.load", 0, 0, "UPS.PowerSummary.PercentLoad", NULL, "%.0f", 0, NULL },
{ "ups.load.high", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.Flow.[4].ConfigPercentLoad", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "ups.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.DelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_FLAG_ABSENT, NULL},
{ "ups.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_FLAG_ABSENT, NULL},
{ "ups.timer.start", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
{ "ups.timer.shutdown", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
{ "ups.timer.reboot", 0, 0, "UPS.PowerSummary.DelayBeforeReboot", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL},
{ "ups.test.result", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "%s", 0, test_read_info },
{ "ups.test.interval", ST_FLAG_RW | ST_FLAG_STRING, 8, "UPS.BatterySystem.Battery.TestPeriod", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "ups.beeper.status", 0 ,0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "%s", HU_FLAG_SEMI_STATIC, beeper_info },
{ "ups.temperature", 0, 0, "UPS.PowerSummary.Temperature", NULL, "%s", 0, kelvin_celsius_conversion },
{ "ups.power", 0, 0, "UPS.PowerConverter.Output.ApparentPower", NULL, "%.0f", 0, NULL },
{ "ups.L1.power", 0, 0, "UPS.PowerConverter.Output.Phase.[1].ApparentPower", NULL, "%.0f", 0, NULL },
{ "ups.L2.power", 0, 0, "UPS.PowerConverter.Output.Phase.[2].ApparentPower", NULL, "%.0f", 0, NULL },
{ "ups.L3.power", 0, 0, "UPS.PowerConverter.Output.Phase.[3].ApparentPower", NULL, "%.0f", 0, NULL },
{ "ups.power.nominal", 0, 0, "UPS.Flow.[4].ConfigApparentPower", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "ups.realpower", 0, 0, "UPS.PowerConverter.Output.ActivePower", NULL, "%.0f", 0, NULL },
{ "ups.L1.realpower", 0, 0, "UPS.PowerConverter.Output.Phase.[1].ActivePower", NULL, "%.0f", 0, NULL },
{ "ups.L2.realpower", 0, 0, "UPS.PowerConverter.Output.Phase.[2].ActivePower", NULL, "%.0f", 0, NULL },
{ "ups.L3.realpower", 0, 0, "UPS.PowerConverter.Output.Phase.[3].ActivePower", NULL, "%.0f", 0, NULL },
{ "ups.realpower.nominal", 0, 0, "UPS.Flow.[4].ConfigActivePower", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "ups.start.auto", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[1].AutomaticRestart", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info },
{ "ups.start.battery", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[3].StartOnBattery", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info },
{ "ups.start.reboot", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.ForcedReboot", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info },
{ "ups.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.PresentStatus.Switchable", NULL, "%s", HU_FLAG_SEMI_STATIC | HU_FLAG_ENUM, eaton_enable_disable_info },
#ifdef HAVE_STRPTIME
{ "ups.date", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.Time", NULL, "%s", 0, mge_date_conversion },
{ "ups.time", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.Time", NULL, "%s", 0, mge_time_conversion },
#else
{ "ups.date", 0, 0, "UPS.PowerSummary.Time", NULL, "%s", 0, mge_date_conversion },
{ "ups.time", 0, 0, "UPS.PowerSummary.Time", NULL, "%s", 0, mge_time_conversion },
#endif /* HAVE_STRPTIME */
{ "ups.type", 0, 0, "UPS.PowerConverter.ConverterType", NULL, "%s", HU_FLAG_STATIC, mge_upstype_conversion },
/* Special case: boolean values that are mapped to ups.status and ups.alarm */
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ACPresent", NULL, NULL, HU_FLAG_QUICK_POLL, online_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[3].PresentStatus.Used", NULL, NULL, 0, mge_onbatt_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.Used", NULL, NULL, 0, online_info },
/* These 2 ones are used when ABM is disabled */
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Discharging", NULL, NULL, HU_FLAG_QUICK_POLL, eaton_discharging_info },
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Charging", NULL, NULL, HU_FLAG_QUICK_POLL, eaton_charging_info },
/* And this one when ABM is enabled (same as battery.charger.status) */
{ "BOOL", 0, 0, "UPS.BatterySystem.Charger.Mode", NULL, "%.0f", HU_FLAG_QUICK_POLL, eaton_abm_chrg_dischrg_info },
/* FIXME: on Dell, the above requires an "AND" with "UPS.BatterySystem.Charger.Mode = 1" */
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit", NULL, NULL, HU_FLAG_QUICK_POLL, lowbatt_info },
/* Output overload, Level 1 (FIXME: add the level?) */
{ "BOOL", 0, 0, "UPS.PowerConverter.Output.Overload.[1].PresentStatus.OverThreshold", NULL, NULL, 0, overload_info },
/* Output overload, Level 2 (FIXME: add the level?) */
{ "BOOL", 0, 0, "UPS.PowerConverter.Output.Overload.[2].PresentStatus.OverThreshold", NULL, NULL, 0, overload_info },
/* Output overload, Level 3 (FIXME: add the level?) */
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Overload", NULL, NULL, 0, overload_info },
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.NeedReplacement", NULL, NULL, 0, replacebatt_info },
/* FIXME: on Dell, the above requires an "AND" with "UPS.BatterySystem.Battery.Test = 3 " */
{ "BOOL", 0, 0, "UPS.LCMSystem.LCMAlarm.[2].PresentStatus.TimerExpired", NULL, NULL, 0, replacebatt_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.Buck", NULL, NULL, 0, trim_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.Boost", NULL, NULL, 0, boost_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.VoltageOutOfRange", NULL, NULL, 0, vrange_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.FrequencyOutOfRange", NULL, NULL, 0, frange_info },
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Good", NULL, NULL, 0, off_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[2].PresentStatus.Used", NULL, NULL, 0, bypass_auto_info }, /* Automatic bypass */
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[4].PresentStatus.Used", NULL, NULL, 0, bypass_manual_info }, /* Manual bypass */
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.FanFailure", NULL, NULL, 0, fanfail_info },
{ "BOOL", 0, 0, "UPS.BatterySystem.Battery.PresentStatus.Present", NULL, NULL, 0, nobattery_info },
{ "BOOL", 0, 0, "UPS.BatterySystem.Charger.PresentStatus.InternalFailure", NULL, NULL, 0, chargerfail_info },
{ "BOOL", 0, 0, "UPS.BatterySystem.Charger.PresentStatus.VoltageTooHigh", NULL, NULL, 0, battvolthi_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.VoltageTooHigh", NULL, NULL, 0, battvolthi_info },
/* Battery DC voltage too high! */
{ "BOOL", 0, 0, "UPS.BatterySystem.Battery.PresentStatus.VoltageTooHigh", NULL, NULL, 0, battvolthi_info },
{ "BOOL", 0, 0, "UPS.BatterySystem.Charger.PresentStatus.VoltageTooLow", NULL, NULL, 0, battvoltlo_info },
{ "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.VoltageTooLow", NULL, NULL, 0, mge_onbatt_info },
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.InternalFailure", NULL, NULL, 0, commfault_info },
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.OverTemperature", NULL, NULL, 0, overheat_info },
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ShutdownImminent", NULL, NULL, 0, shutdownimm_info },
/* Vendor specific ups.alarm */
{ "ups.alarm", 0, 0, "UPS.PowerSummary.PresentStatus.EmergencyStop", NULL, NULL, 0, mge_emergency_stop },
{ "ups.alarm", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.WiringFault", NULL, NULL, 0, mge_wiring_fault },
{ "ups.alarm", 0, 0, "UPS.PowerSummary.PresentStatus.ConfigurationFailure", NULL, NULL, 0, mge_config_failure },
{ "ups.alarm", 0, 0, "UPS.PowerConverter.Inverter.PresentStatus.VoltageTooHigh", NULL, NULL, 0, mge_inverter_volthi },
{ "ups.alarm", 0, 0, "UPS.PowerConverter.Inverter.PresentStatus.VoltageTooLow", NULL, NULL, 0, mge_inverter_voltlo },
{ "ups.alarm", 0, 0, "UPS.PowerConverter.Output.PresentStatus.ShortCircuit", NULL, NULL, 0, mge_short_circuit },
/* Input page */
{ "input.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Voltage", NULL, "%.1f", 0, NULL },
{ "input.L1-N.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[1].Voltage", NULL, "%.1f", 0, NULL },
{ "input.L2-N.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[2].Voltage", NULL, "%.1f", 0, NULL },
{ "input.L3-N.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[3].Voltage", NULL, "%.1f", 0, NULL },
{ "input.L1-L2.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[12].Voltage", NULL, "%.1f", 0, NULL },
{ "input.L2-L3.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[23].Voltage", NULL, "%.1f", 0, NULL },
{ "input.L3-L1.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[31].Voltage", NULL, "%.1f", 0, NULL },
{ "input.voltage.nominal", 0, 0, "UPS.Flow.[1].ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "input.current", 0, 0, "UPS.PowerConverter.Input.[1].Current", NULL, "%.2f", 0, NULL },
{ "input.L1.current", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[1].Current", NULL, "%.1f", 0, NULL },
{ "input.L2.current", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[2].Current", NULL, "%.1f", 0, NULL },
{ "input.L3.current", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[3].Current", NULL, "%.1f", 0, NULL },
{ "input.current.nominal", 0, 0, "UPS.Flow.[1].ConfigCurrent", NULL, "%.2f", HU_FLAG_STATIC, NULL },
{ "input.frequency", 0, 0, "UPS.PowerConverter.Input.[1].Frequency", NULL, "%.1f", 0, NULL },
{ "input.frequency.nominal", 0, 0, "UPS.Flow.[1].ConfigFrequency", NULL, "%.0f", HU_FLAG_STATIC, NULL },
/* same as "input.transfer.boost.low" */
{ "input.transfer.low", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.LowVoltageTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "input.transfer.boost.low", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.LowVoltageBoostTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "input.transfer.boost.high", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.HighVoltageBoostTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "input.transfer.trim.low", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.LowVoltageBuckTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
/* same as "input.transfer.trim.high" */
{ "input.transfer.high", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.HighVoltageTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "input.transfer.trim.high", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.HighVoltageBuckTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "input.sensitivity", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerConverter.Output.SensitivityMode", NULL, "%s", HU_FLAG_SEMI_STATIC, mge_sensitivity_info },
{ "input.voltage.extended", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.ExtendedVoltageMode", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info },
{ "input.frequency.extended", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.ExtendedFrequencyMode", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info },
/* Bypass page */
{ "input.bypass.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Voltage", NULL, "%.1f", 0, NULL },
{ "input.bypass.L1-N.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[1].Voltage", NULL, "%.1f", 0, NULL },
{ "input.bypass.L2-N.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[2].Voltage", NULL, "%.1f", 0, NULL },
{ "input.bypass.L3-N.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[3].Voltage", NULL, "%.1f", 0, NULL },
{ "input.bypass.L1-L2.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[12].Voltage", NULL, "%.1f", 0, NULL },
{ "input.bypass.L2-L3.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[23].Voltage", NULL, "%.1f", 0, NULL },
{ "input.bypass.L3-L1.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[31].Voltage", NULL, "%.1f", 0, NULL },
{ "input.bypass.voltage.nominal", 0, 0, "UPS.Flow.[2].ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "input.bypass.current", 0, 0, "UPS.PowerConverter.Input.[2].Current", NULL, "%.2f", 0, NULL },
{ "input.bypass.L1.current", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[1].Current", NULL, "%.1f", 0, NULL },
{ "input.bypass.L2.current", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[2].Current", NULL, "%.1f", 0, NULL },
{ "input.bypass.L3.current", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[3].Current", NULL, "%.1f", 0, NULL },
{ "input.bypass.current.nominal", 0, 0, "UPS.Flow.[2].ConfigCurrent", NULL, "%.2f", HU_FLAG_STATIC, NULL },
{ "input.bypass.frequency", 0, 0, "UPS.PowerConverter.Input.[2].Frequency", NULL, "%.1f", 0, NULL },
{ "input.bypass.frequency.nominal", 0, 0, "UPS.Flow.[2].ConfigFrequency", NULL, "%.0f", HU_FLAG_STATIC, NULL },
/* Output page */
{ "output.voltage", 0, 0, "UPS.PowerConverter.Output.Voltage", NULL, "%.1f", 0, NULL },
{ "output.L1-N.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[1].Voltage", NULL, "%.1f", 0, NULL },
{ "output.L2-N.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[2].Voltage", NULL, "%.1f", 0, NULL },
{ "output.L3-N.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[3].Voltage", NULL, "%.1f", 0, NULL },
{ "output.L1-L2.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[12].Voltage", NULL, "%.1f", 0, NULL },
{ "output.L2-L3.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[23].Voltage", NULL, "%.1f", 0, NULL },
{ "output.L3-L1.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[31].Voltage", NULL, "%.1f", 0, NULL },
{ "output.voltage.nominal", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.Flow.[4].ConfigVoltage", NULL, "%.0f", HU_FLAG_SEMI_STATIC | HU_FLAG_ENUM, nominal_output_voltage_info },
{ "output.current", 0, 0, "UPS.PowerConverter.Output.Current", NULL, "%.2f", 0, NULL },
{ "output.L1.current", 0, 0, "UPS.PowerConverter.Output.Phase.[1].Current", NULL, "%.1f", 0, NULL },
{ "output.L2.current", 0, 0, "UPS.PowerConverter.Output.Phase.[2].Current", NULL, "%.1f", 0, NULL },
{ "output.L3.current", 0, 0, "UPS.PowerConverter.Output.Phase.[3].Current", NULL, "%.1f", 0, NULL },
{ "output.current.nominal", 0, 0, "UPS.Flow.[4].ConfigCurrent", NULL, "%.2f", 0, NULL },
{ "output.frequency", 0, 0, "UPS.PowerConverter.Output.Frequency", NULL, "%.1f", 0, NULL },
/* FIXME: can be RW (50/60) (or on .nominal)? */
{ "output.frequency.nominal", 0, 0, "UPS.Flow.[4].ConfigFrequency", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "output.powerfactor", 0, 0, "UPS.PowerConverter.Output.PowerFactor", NULL, "%s", 0, mge_powerfactor_conversion },
/* Outlet page (using MGE UPS SYSTEMS - PowerShare technology) */
{ "outlet.id", 0, 0, "UPS.OutletSystem.Outlet.[1].OutletID", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "outlet.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, "UPS.OutletSystem.Outlet.[1].OutletID", NULL, "Main Outlet", HU_FLAG_ABSENT, NULL },
{ "outlet.switchable", 0, 0, "UPS.OutletSystem.Outlet.[1].PresentStatus.Switchable", NULL, "%s", HU_FLAG_STATIC, yes_no_info },
/* On Protection Station, the line below is the power consumption threshold
* on the master outlet used to automatically power off the slave outlets.
* Values: 10, 25 (default) or 60 VA. */
{ "outlet.power", ST_FLAG_RW | ST_FLAG_STRING, 6, "UPS.OutletSystem.Outlet.[1].ConfigApparentPower", NULL, "%s", HU_FLAG_SEMI_STATIC | HU_FLAG_ENUM, pegasus_threshold_info },
{ "outlet.power", 0, 0, "UPS.OutletSystem.Outlet.[1].ApparentPower", NULL, "%.0f", 0, NULL },
{ "outlet.realpower", 0, 0, "UPS.OutletSystem.Outlet.[1].ActivePower", NULL, "%.0f", 0, NULL },
{ "outlet.current", 0, 0, "UPS.OutletSystem.Outlet.[1].Current", NULL, "%.2f", 0, NULL },
{ "outlet.powerfactor", 0, 0, "UPS.OutletSystem.Outlet.[1].PowerFactor", NULL, "%.2f", 0, NULL }, /* "%s", 0, mge_powerfactor_conversion }, */
/* First outlet */
{ "outlet.1.id", 0, 0, "UPS.OutletSystem.Outlet.[2].OutletID", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "outlet.1.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, "UPS.OutletSystem.Outlet.[2].OutletID", NULL, "PowerShare Outlet 1", HU_FLAG_ABSENT, NULL },
{ "outlet.1.switchable", 0, 0, "UPS.OutletSystem.Outlet.[2].PresentStatus.Switchable", NULL, "%s", HU_FLAG_STATIC, yes_no_info },
{ "outlet.1.status", 0, 0, "UPS.OutletSystem.Outlet.[2].PresentStatus.SwitchOn/Off", NULL, "%s", 0, on_off_info },
/* For low end models, with 1 non backup'ed outlet */
{ "outlet.1.status", 0, 0, "UPS.PowerSummary.PresentStatus.ACPresent", NULL, "%s", 0, on_off_info },
/* FIXME: change to outlet.1.battery.charge.low, as in mge-xml.c?! */
{ "outlet.1.autoswitch.charge.low", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.OutletSystem.Outlet.[2].RemainingCapacityLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "outlet.1.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.OutletSystem.Outlet.[2].ShutdownTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "outlet.1.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.OutletSystem.Outlet.[2].StartupTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "outlet.1.power", 0, 0, "UPS.OutletSystem.Outlet.[2].ApparentPower", NULL, "%.0f", 0, NULL },
{ "outlet.1.realpower", 0, 0, "UPS.OutletSystem.Outlet.[2].ActivePower", NULL, "%.0f", 0, NULL },
{ "outlet.1.current", 0, 0, "UPS.OutletSystem.Outlet.[2].Current", NULL, "%.2f", 0, NULL },
{ "outlet.1.powerfactor", 0, 0, "UPS.OutletSystem.Outlet.[2].PowerFactor", NULL, "%.2f", 0, NULL }, /* "%s", 0, mge_powerfactor_conversion }, */
/* Second outlet */
{ "outlet.2.id", 0, 0, "UPS.OutletSystem.Outlet.[3].OutletID", NULL, "%.0f", HU_FLAG_STATIC, NULL },
{ "outlet.2.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, "UPS.OutletSystem.Outlet.[3].OutletID", NULL, "PowerShare Outlet 2", HU_FLAG_ABSENT, NULL },
/* needed for Pegasus to enable master/slave mode:
* FIXME: rename to something more suitable (outlet.?) */
{ "outlet.2.switchable", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.OutletSystem.Outlet.[3].PresentStatus.Switchable", NULL, "%s", HU_FLAG_SEMI_STATIC, pegasus_yes_no_info },
/* Generic version (RO) for other models */
{ "outlet.2.switchable", 0, 0, "UPS.OutletSystem.Outlet.[3].PresentStatus.Switchable", NULL, "%s", 0, yes_no_info },
{ "outlet.2.status", 0, 0, "UPS.OutletSystem.Outlet.[3].PresentStatus.SwitchOn/Off", NULL, "%s", 0, on_off_info },
{ "outlet.2.autoswitch.charge.low", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.OutletSystem.Outlet.[3].RemainingCapacityLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "outlet.2.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.OutletSystem.Outlet.[3].ShutdownTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "outlet.2.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.OutletSystem.Outlet.[3].StartupTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
{ "outlet.2.power", 0, 0, "UPS.OutletSystem.Outlet.[3].ApparentPower", NULL, "%.0f", 0, NULL },
{ "outlet.2.realpower", 0, 0, "UPS.OutletSystem.Outlet.[3].ActivePower", NULL, "%.0f", 0, NULL },
{ "outlet.2.current", 0, 0, "UPS.OutletSystem.Outlet.[3].Current", NULL, "%.2f", 0, NULL },
{ "outlet.2.powerfactor", 0, 0, "UPS.OutletSystem.Outlet.[3].PowerFactor", NULL, "%.2f", 0, NULL }, /* "%s", 0, mge_powerfactor_conversion }, */
/* instant commands. */
/* splited into subset while waiting for extradata support
* ie: test.battery.start quick
*/
{ "test.battery.start.quick", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "1", HU_TYPE_CMD, NULL },
{ "test.battery.start.deep", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "2", HU_TYPE_CMD, NULL },
{ "test.battery.stop", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "3", HU_TYPE_CMD, NULL },
{ "load.off.delay", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_TYPE_CMD, NULL },
{ "load.on.delay", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_TYPE_CMD, NULL },
{ "shutdown.stop", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, "-1", HU_TYPE_CMD, NULL },
{ "shutdown.reboot", 0, 0, "UPS.PowerSummary.DelayBeforeReboot", NULL, "10", HU_TYPE_CMD, NULL},
{ "beeper.off", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "1", HU_TYPE_CMD, NULL },
{ "beeper.on", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "2", HU_TYPE_CMD, NULL },
{ "beeper.mute", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "3", HU_TYPE_CMD, NULL },
{ "beeper.disable", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "1", HU_TYPE_CMD, NULL },
{ "beeper.enable", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "2", HU_TYPE_CMD, NULL },
/* Command for the outlet collection */
{ "outlet.1.load.off", 0, 0, "UPS.OutletSystem.Outlet.[2].DelayBeforeShutdown", NULL, "0", HU_TYPE_CMD, NULL },
{ "outlet.1.load.on", 0, 0, "UPS.OutletSystem.Outlet.[2].DelayBeforeStartup", NULL, "0", HU_TYPE_CMD, NULL },
{ "outlet.2.load.off", 0, 0, "UPS.OutletSystem.Outlet.[3].DelayBeforeShutdown", NULL, "0", HU_TYPE_CMD, NULL },
{ "outlet.2.load.on", 0, 0, "UPS.OutletSystem.Outlet.[3].DelayBeforeStartup", NULL, "0", HU_TYPE_CMD, NULL },
/* end of structure. */
{ NULL }
};
/*
* All the logic for finely formatting the MGE model name and device
* type matching (used for device specific values or corrections).
* Returns pointer to (dynamically allocated) model name.
*/
static char *get_model_name(const char *iProduct, const char *iModel)
{
models_name_t *model = NULL;
upsdebugx(2, "get_model_name(%s, %s)\n", iProduct, iModel);
/* Search for device type and formatting rules */
for (model = mge_model_names; model->iProduct; model++) {
if(model->name) {
upsdebugx(2, "comparing with: %s", model->name);
}
else {
upsdebugx(2, "comparing with: %s %s", model->iProduct,
model->iModel);
}
if (strcmp(iProduct, model->iProduct)) {
continue;
}
if (strcmp(iModel, model->iModel)) {
continue;
}
mge_type = model->type;
break;
}
if (!model->name) {
/*
* Model not found or NULL (use default) so construct
* model name by concatenation of iProduct and iModel
*/
char buf[SMALLBUF];
snprintf(buf, sizeof(buf), "%s %s", iProduct, iModel);
return strdup(buf);
}
return strdup(model->name);
}
static const char *mge_format_model(HIDDevice_t *hd) {
char product[SMALLBUF];
char model[SMALLBUF];
double value;
/* Dell has already a fully formatted name in iProduct */
if (hd->VendorID == DELL_VENDORID) {
return hd->Product;
}
/* Get iProduct and iModel strings */
snprintf(product, sizeof(product), "%s", hd->Product ? hd->Product : "unknown");
HIDGetItemString(udev, "UPS.PowerSummary.iModel", model, sizeof(model), mge_utab);
/* Fallback to ConfigApparentPower */
if ((strlen(model) < 1) && (HIDGetItemValue(udev, "UPS.Flow.[4].ConfigApparentPower", &value, mge_utab) == 1 )) {
snprintf(model, sizeof(model), "%i", (int)value);
}
if (strlen(model) > 0) {
free(hd->Product);
hd->Product = get_model_name(product, model);
}
return hd->Product;
}
static const char *mge_format_mfr(HIDDevice_t *hd) {
return hd->Vendor ? hd->Vendor : "Eaton";
}
static const char *mge_format_serial(HIDDevice_t *hd) {
return hd->Serial;
}
/* this function allows the subdriver to "claim" a device: return 1 if
* the device is supported by this subdriver, else 0. */
static int mge_claim(HIDDevice_t *hd) {
#ifndef SHUT_MODE
int status = is_usb_device_supported(mge_usb_device_table, hd);
switch (status) {
case POSSIBLY_SUPPORTED:
switch (hd->VendorID)
{
case HP_VENDORID:
case DELL_VENDORID:
/* by default, reject, unless the productid option is given */
if (getval("productid")) {
return 1;
}
/*
* this vendor makes lots of USB devices that are
* not a UPS, so don't use possibly_supported here
*/
return 0;
default: /* Valid for Eaton */
/* by default, reject, unless the productid option is given */
if (getval("productid")) {
return 1;
}
possibly_supported("Eaton / MGE", hd);
return 0;
}
case SUPPORTED:
return 1;
case NOT_SUPPORTED:
default:
return 0;
}
#else
return 1;
#endif
}
subdriver_t mge_subdriver = {
MGE_HID_VERSION,
mge_claim,
mge_utab,
mge_hid2nut,
mge_format_model,
mge_format_mfr,
mge_format_serial,
};