#! /bin/sh
|
|
### BEGIN INIT INFO
|
|
# Provides: nut-client upsmon ups-monitor
|
|
# Required-Start: $local_fs $syslog $network $remote_fs
|
|
# Required-Stop: $local_fs $syslog $network $remote_fs
|
|
# Should-Start: nut-server
|
|
# Should-Stop:
|
|
# Default-Start: 2 3 4 5
|
|
# Default-Stop: 0 1 6
|
|
# Short-Description: Network UPS Tools monitor initscript
|
|
# Description: This script take care of starting and stopping the
|
|
# Network UPS Tools monitoring component (upsmon).
|
|
### END INIT INFO
|
|
|
|
# Author: Arnaud Quette <aquette@debian.org>
|
|
|
|
PATH=/sbin:/usr/sbin:/bin:/usr/bin:/usr/local/sbin:/usr/local/bin
|
|
|
|
NAME=nut-client
|
|
DESC="NUT - power device monitor and shutdown controller"
|
|
CONFIG=/etc/nut/nut.conf
|
|
pid_dir=/var/run/nut
|
|
upsmon_pid=${pid_dir}/upsmon.pid
|
|
upsmon=/sbin/upsmon
|
|
log=">/dev/null 2>/dev/null"
|
|
|
|
# Define LSB log_* functions.
|
|
# Depend on lsb-base (>= 3.0-6) to ensure that this file is present.
|
|
. /lib/lsb/init-functions
|
|
|
|
# set upsmon specific options. use "man upsmon" for more info
|
|
# this parameter is now located in nut.conf, and not in /etc/default/nut anymore
|
|
# FIXME: retrieved from 'nut' script during update
|
|
UPSMON_OPTIONS=""
|
|
|
|
# Exit if the package is not installed
|
|
[ -x "$upsmon" ] || exit 0
|
|
|
|
# Include NUT nut.conf
|
|
[ -r $CONFIG ] && . $CONFIG
|
|
|
|
# FIXME: put all common bits, between nut-client and nut-server,
|
|
# into a common nut-function
|
|
|
|
# Explicitly require the configuration to be done in /etc/nut/nut.conf
|
|
if [ "x$MODE" = "xnone" -o -z "$MODE" ] ; then
|
|
log_action_msg "$NAME disabled, please adjust the configuration to your needs"
|
|
log_action_msg "Then set MODE to a suitable value in $CONFIG to enable it"
|
|
# exit success to avoid breaking the install process!
|
|
exit 0
|
|
fi
|
|
|
|
# Check if /var/run/nut exists and has the correct perms
|
|
check_var_directory() {
|
|
[ ! -d ${pid_dir} ] && mkdir -p ${pid_dir} \
|
|
&& chown root:nut ${pid_dir} \
|
|
&& chmod 770 ${pid_dir}
|
|
}
|
|
|
|
# check if the right components are running
|
|
check_status() {
|
|
case "$MODE" in
|
|
standalone|netserver|netclient)
|
|
status_of_proc -p $upsmon_pid $upsmon upsmon
|
|
;;
|
|
none|*)
|
|
;;
|
|
esac
|
|
}
|
|
|
|
start_stop_client () {
|
|
case "$MODE" in
|
|
standalone|netserver|netclient)
|
|
# FIXME: for standalone|netserver, ensure 'nut-server status' returns ?
|
|
case "$1" in
|
|
start)
|
|
start-stop-daemon -S -q -p $upsmon_pid -x $upsmon \
|
|
-- $UPSMON_OPTIONS >/dev/null 2>&1 && return 0 || return 1
|
|
;;
|
|
stop)
|
|
start-stop-daemon -K -o -q -p $upsmon_pid -n upsmon >/dev/null 2>&1 \
|
|
&& return 0 || return 1
|
|
;;
|
|
esac
|
|
;;
|
|
none|*)
|
|
return 1
|
|
;;
|
|
esac
|
|
}
|
|
|
|
case "$1" in
|
|
|
|
start)
|
|
log_daemon_msg "Starting $DESC" "$NAME"
|
|
check_var_directory
|
|
start_stop_client start
|
|
log_end_msg $?
|
|
;;
|
|
|
|
stop)
|
|
log_daemon_msg "Stopping $DESC" "$NAME"
|
|
start_stop_client stop
|
|
log_end_msg $?
|
|
;;
|
|
|
|
reload)
|
|
log_daemon_msg "Reloading $DESC" "$NAME"
|
|
$upsmon -c reload >/dev/null 2>&1
|
|
log_end_msg $?
|
|
;;
|
|
|
|
restart|force-reload)
|
|
# FIXME: lack consistency, due to initscript split.
|
|
# This only addresses partial reload.
|
|
# Full reload requires to:
|
|
# - stop nut-client
|
|
# - restart (Ie stop+start) nut-server
|
|
# - start nut-client
|
|
log_daemon_msg "Restarting $DESC" "$NAME"
|
|
start_stop_client stop || true
|
|
# should then 'start_stop_server stop', Ie /etc/init.d/nut-server stop
|
|
#sleep 5
|
|
check_var_directory
|
|
# should first 'start_stop_server start', Ie /etc/init.d/nut-server start
|
|
start_stop_client start
|
|
log_end_msg $?
|
|
;;
|
|
|
|
status)
|
|
#log_daemon_msg "Checking status of $DESC"
|
|
echo "Checking status of $DESC"
|
|
check_status
|
|
exit $?
|
|
;;
|
|
|
|
poweroff)
|
|
case "$MODE" in
|
|
standalone|netserver)
|
|
# Sanity check
|
|
flag=`sed -ne 's#^ *POWERDOWNFLAG *\(.*\)$#\1#p' /etc/nut/upsmon.conf`
|
|
if [ -z "$flag" ] ; then
|
|
log_action_msg "##########################################################"
|
|
log_action_msg "## POWERDOWNFLAG is not defined in /etc/nut/upsmon.conf ##"
|
|
log_action_msg "## ##"
|
|
log_action_msg "## Please read the Manual page upsmon.conf(5) ##"
|
|
log_action_msg "##########################################################"
|
|
exit 1
|
|
fi
|
|
|
|
# Defer to nut-server to actually poweroff the UPS, if needed
|
|
# (the need is tested here though!)
|
|
if $upsmon -K >/dev/null 2>&1 ; then
|
|
log_daemon_msg "UPS poweroff required..."
|
|
log_end_msg 0
|
|
if [ -x /etc/init.d/nut-server ] ; then
|
|
exec /etc/init.d/nut-server poweroff
|
|
else
|
|
log_action_msg "Failure: /etc/init.d/nut-server script missing"
|
|
fi
|
|
else
|
|
log_action_msg "Power down flag is not set (UPS poweroff not needed)"
|
|
fi
|
|
;;
|
|
none|netclient|*)
|
|
# nothing to do
|
|
log_action_msg "'$MODE' configuration does not require UPS poweroff"
|
|
;;
|
|
esac
|
|
;;
|
|
|
|
*)
|
|
N=/etc/init.d/$NAME
|
|
echo "Usage: $N {start|stop|reload|restart|force-reload|status|poweroff}" >&2
|
|
exit 1
|
|
;;
|
|
esac
|
|
|
|
exit 0
|