/* netvision-mib.c - data to monitor Socomec Sicon UPS equipped * with Netvision WEB/SNMP card/external box with NUT * * Copyright (C) * 2004 Thanos Chatziathanassiou * 2012 Manuel Bouyer * 2015 Arnaud Quette * * This program is free software; you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by * the Free Software Foundation; either version 2 of the License, or * (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * * You should have received a copy of the GNU General Public License * along with this program; if not, write to the Free Software * Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA * */ #include "netvision-mib.h" #define NETVISION_MIB_VERSION "0.4" #define NETVISION_SYSOID ".1.3.6.1.4.1.4555.1.1.1" /* SNMP OIDs set */ #define NETVISION_OID_UPS_MIB ".1.3.6.1.4.1.4555.1.1.1.1" #define NETVISION_OID_UPSIDENTMODEL ".1.3.6.1.4.1.4555.1.1.1.1.1.1.0" #define NETVISION_OID_UPSIDENTFWVERSION ".1.3.6.1.4.1.4555.1.1.1.1.1.2.0" #define NETVISION_OID_UPSIDENTAGENTSWVERSION ".1.3.6.1.4.1.4555.1.1.1.1.1.3.0" #define NETVISION_OID_UPSIDENTUPSSERIALNUMBER ".1.3.6.1.4.1.4555.1.1.1.1.1.4.0" /* UPS Battery */ #define NETVISION_OID_BATTERYSTATUS ".1.3.6.1.4.1.4555.1.1.1.1.2.1.0" static info_lkp_t netvision_batt_info[] = { { 2, "" }, /* battery normal */ { 3, "LB" }, /* battery low */ { 4, "LB" }, /* battery depleted */ { 5, "DISCHRG" }, /* battery discharging */ { 6, "RB" }, /* battery failure */ { 0, "NULL" } }; /* Battery status: upsAlarmOnBattery */ static info_lkp_t netvision_onbatt_info[] = { { 0, "OL" }, /* Online */ { 1, "OB" }, /* On battery */ { 0, "NULL" } }; #define NETVISION_OID_SECONDSONBATTERY ".1.3.6.1.4.1.4555.1.1.1.1.2.2.0" #define NETVISION_OID_BATT_RUNTIME_REMAINING ".1.3.6.1.4.1.4555.1.1.1.1.2.3.0" #define NETVISION_OID_BATT_CHARGE ".1.3.6.1.4.1.4555.1.1.1.1.2.4.0" #define NETVISION_OID_BATT_VOLTS ".1.3.6.1.4.1.4555.1.1.1.1.2.5.0" #define NETVISION_OID_INPUT_NUM_LINES ".1.3.6.1.4.1.4555.1.1.1.1.3.1.0" /* 1phase or 3phase UPS input */ #define NETVISION_OID_INPUT_FREQ ".1.3.6.1.4.1.4555.1.1.1.1.3.2.0" #define NETVISION_OID_OUTPUT_NUM_LINES ".1.3.6.1.4.1.4555.1.1.1.1.4.3.0" /* 1phase or 3phase UPS output */ #define NETVISION_OID_OUTPUT_FREQ ".1.3.6.1.4.1.4555.1.1.1.1.4.2.0" #define NETVISION_OID_BYPASS_FREQ ".1.3.6.1.4.1.4555.1.1.1.1.5.1.0" #define NETVISION_OID_BYPASS_NUM_LINES ".1.3.6.1.4.1.4555.1.1.1.1.5.2.0" /* 1phase or 3phase UPS input */ /* three phase ups provide input/output/load for each phase in case of one-phase output, only _P1 should be used */ #define NETVISION_OID_OUT_VOLTAGE_P1 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.1" #define NETVISION_OID_OUT_CURRENT_P1 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.1" #define NETVISION_OID_OUT_LOAD_PCT_P1 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.1" #define NETVISION_OID_IN_VOLTAGE_P1 ".1.3.6.1.4.1.4555.1.1.1.1.3.3.1.5.1" #define NETVISION_OID_IN_CURRENT_P1 ".1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.1" #define NETVISION_OID_BY_VOLTAGE_P1 ".1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.1" #define NETVISION_OID_BY_CURRENT_P1 ".1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.1" #define NETVISION_OID_OUT_VOLTAGE_P2 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.2" #define NETVISION_OID_OUT_CURRENT_P2 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.2" #define NETVISION_OID_OUT_LOAD_PCT_P2 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.2" #define NETVISION_OID_IN_VOLTAGE_P2 ".1.3.6.1.4.1.4555.1.1.1.1.3.3.1.5.2" #define NETVISION_OID_IN_CURRENT_P2 ".1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.2" #define NETVISION_OID_BY_VOLTAGE_P2 ".1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.2" #define NETVISION_OID_BY_CURRENT_P2 ".1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.2" #define NETVISION_OID_OUT_VOLTAGE_P3 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.3" #define NETVISION_OID_OUT_CURRENT_P3 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.3" #define NETVISION_OID_OUT_LOAD_PCT_P3 ".1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.3" #define NETVISION_OID_IN_VOLTAGE_P3 ".1.3.6.1.4.1.4555.1.1.1.1.3.3.1.5.3" #define NETVISION_OID_IN_CURRENT_P3 ".1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.3" #define NETVISION_OID_BY_VOLTAGE_P3 ".1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.3" #define NETVISION_OID_BY_CURRENT_P3 ".1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.3" #define NETVISION_OID_OUTPUT_SOURCE ".1.3.6.1.4.1.4555.1.1.1.1.4.1.0" #define NETVISION_OID_CONTROL_STATUS ".1.3.6.1.4.1.4555.1.1.1.1.8.1" #define NETVISION_OID_CONTROL_SHUTDOWN_DELAY ".1.3.6.1.4.1.4555.1.1.1.1.8.2" static info_lkp_t netvision_output_info[] = { { 1, "" }, /* output source other */ { 2, "" }, /* output source none */ { 3, "OL" }, /* output source normal */ { 4, "OL BYPASS" }, /* output source bypass */ { 5, "OB" }, /* output source battery */ { 6, "OL BOOST" }, /* output source booster */ { 7, "OL TRIM" }, /* output source reducer */ { 8, "OL" }, /* output source standby */ { 9, "" }, /* output source ecomode */ { 0, "NULL" } }; /* Snmp2NUT lookup table */ static snmp_info_t netvision_mib[] = { { "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NETVISION_OID_UPSIDENTAGENTSWVERSION, "SOCOMEC SICON UPS", SU_FLAG_STATIC | SU_FLAG_OK, NULL }, { "ups.model", ST_FLAG_STRING, SU_INFOSIZE, NETVISION_OID_UPSIDENTMODEL, "Generic SNMP UPS", SU_FLAG_STATIC | SU_FLAG_OK, NULL }, { "ups.serial", ST_FLAG_STRING, SU_INFOSIZE, NETVISION_OID_UPSIDENTUPSSERIALNUMBER, "", SU_FLAG_STATIC | SU_FLAG_OK, NULL }, { "ups.firmware.aux", ST_FLAG_STRING, SU_INFOSIZE, NETVISION_OID_UPSIDENTFWVERSION, "", SU_FLAG_STATIC | SU_FLAG_OK, NULL }, { "ups.status", ST_FLAG_STRING, SU_INFOSIZE, NETVISION_OID_BATTERYSTATUS, "", SU_FLAG_OK | SU_STATUS_BATT, &netvision_batt_info[0] }, { "ups.status", ST_FLAG_STRING, SU_INFOSIZE, NETVISION_OID_OUTPUT_SOURCE, "", SU_FLAG_OK | SU_STATUS_PWR, &netvision_output_info[0] }, /* upsAlarmOnBattery */ { "ups.status", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.4555.1.1.1.1.6.3.2.0", "", SU_FLAG_OK | SU_STATUS_PWR, &netvision_onbatt_info[0] }, /* ups load */ { "ups.load", 0, 1, NETVISION_OID_OUT_LOAD_PCT_P1, 0, SU_INPUT_1, NULL }, /*ups input,output voltage, output frquency phase 1 */ { "input.phases", 0, 1.0, NETVISION_OID_INPUT_NUM_LINES, 0, SU_FLAG_SETINT, NULL, &input_phases }, { "input.frequency", 0, 0.1, NETVISION_OID_INPUT_FREQ, 0, SU_FLAG_OK, NULL }, { "input.voltage", 0, 0.1, NETVISION_OID_IN_VOLTAGE_P1, 0, SU_INPUT_1, NULL }, { "input.current", 0, 0.1, NETVISION_OID_IN_CURRENT_P1, 0, SU_INPUT_1, NULL }, { "input.L1-N.voltage", 0, 0.1, NETVISION_OID_IN_VOLTAGE_P1, 0, SU_INPUT_3, NULL }, { "input.L1.current", 0, 0.1, NETVISION_OID_IN_CURRENT_P1, 0, SU_INPUT_3, NULL }, { "input.L2-N.voltage", 0, 0.1, NETVISION_OID_IN_VOLTAGE_P2, 0, SU_INPUT_3, NULL }, { "input.L2.current", 0, 0.1, NETVISION_OID_IN_CURRENT_P2, 0, SU_INPUT_3, NULL }, { "input.L3-N.voltage", 0, 0.1, NETVISION_OID_IN_VOLTAGE_P3, 0, SU_INPUT_3, NULL }, { "input.L3.current", 0, 0.1, NETVISION_OID_IN_CURRENT_P3, 0, SU_INPUT_3, NULL }, { "output.phases", 0, 1.0, NETVISION_OID_OUTPUT_NUM_LINES, 0, SU_FLAG_SETINT, NULL, &output_phases }, { "output.frequency", 0, 0.1, NETVISION_OID_OUTPUT_FREQ, 0, SU_FLAG_OK, NULL }, { "output.voltage", 0, 0.1, NETVISION_OID_OUT_VOLTAGE_P1, 0, SU_OUTPUT_1, NULL }, { "output.current", 0, 0.1, NETVISION_OID_OUT_CURRENT_P1, 0, SU_OUTPUT_1, NULL }, { "output.load", 0, 1.0, NETVISION_OID_OUT_LOAD_PCT_P1, 0, SU_OUTPUT_1, NULL }, { "output.L1-N.voltage", 0, 0.1, NETVISION_OID_OUT_VOLTAGE_P1, 0, SU_OUTPUT_3, NULL }, { "output.L1.current", 0, 0.1, NETVISION_OID_OUT_CURRENT_P1, 0, SU_OUTPUT_3, NULL }, { "output.L1.power.percent", 0, 1.0, NETVISION_OID_OUT_LOAD_PCT_P1, 0, SU_OUTPUT_3, NULL }, { "output.L2-N.voltage", 0, 0.1, NETVISION_OID_OUT_VOLTAGE_P2, 0, SU_OUTPUT_3, NULL }, { "output.L2.current", 0, 0.1, NETVISION_OID_OUT_CURRENT_P2, 0, SU_OUTPUT_3, NULL }, { "output.L2.power.percent", 0, 1.0, NETVISION_OID_OUT_LOAD_PCT_P2, 0, SU_OUTPUT_3, NULL }, { "output.L3-N.voltage", 0, 0.1, NETVISION_OID_OUT_VOLTAGE_P3, 0, SU_OUTPUT_3, NULL }, { "output.L3.current", 0, 0.1, NETVISION_OID_OUT_CURRENT_P3, 0, SU_OUTPUT_3, NULL }, { "output.L3.power.percent", 0, 1.0, NETVISION_OID_OUT_LOAD_PCT_P3, 0, SU_OUTPUT_3, NULL }, { "input.bypass.phases", 0, 1.0, NETVISION_OID_BYPASS_NUM_LINES, 0, SU_FLAG_SETINT, NULL, &bypass_phases }, { "input.bypass.frequency", 0, 0.1, NETVISION_OID_BYPASS_FREQ, 0, SU_FLAG_OK, NULL }, { "input.bypass.voltage", 0, 0.1, NETVISION_OID_BY_VOLTAGE_P1, 0, SU_BYPASS_1, NULL }, { "input.bypass.current", 0, 0.1, NETVISION_OID_BY_CURRENT_P1, 0, SU_BYPASS_1, NULL }, { "input.bypass.L1-N.voltage", 0, 0.1, NETVISION_OID_BY_VOLTAGE_P1, 0, SU_BYPASS_3, NULL }, { "input.bypass.L1.current", 0, 0.1, NETVISION_OID_BY_CURRENT_P1, 0, SU_BYPASS_3, NULL }, { "input.bypass.L2-N.voltage", 0, 0.1, NETVISION_OID_BY_VOLTAGE_P2, 0, SU_BYPASS_3, NULL }, { "input.bypass.L2.current", 0, 0.1, NETVISION_OID_BY_CURRENT_P2, 0, SU_BYPASS_3, NULL }, { "input.bypass.L3-N.voltage", 0, 0.1, NETVISION_OID_BY_VOLTAGE_P3, 0, SU_BYPASS_3, NULL }, { "input.bypass.L3.current", 0, 0.1, NETVISION_OID_BY_CURRENT_P3, 0, SU_BYPASS_3, NULL }, /* battery info */ { "battery.charge", 0, 1, NETVISION_OID_BATT_CHARGE, "", SU_FLAG_OK, NULL }, { "battery.voltage", 0, 0.1, NETVISION_OID_BATT_VOLTS, "", SU_FLAG_OK, NULL }, { "battery.runtime", 0, 60, NETVISION_OID_BATT_RUNTIME_REMAINING, "", SU_FLAG_OK, NULL }, /* end of structure. */ { NULL, 0, 0, NULL, NULL, 0, NULL } }; mib2nut_info_t netvision = { "netvision", NETVISION_MIB_VERSION, "", NETVISION_OID_UPSIDENTMODEL, netvision_mib, NETVISION_SYSOID };