'\" t .\" Title: upscode2 .\" Author: [see the "AUTHORS" section] .\" Generator: DocBook XSL Stylesheets vsnapshot .\" Date: 04/26/2022 .\" Manual: NUT Manual .\" Source: Network UPS Tools 2.8.0 .\" Language: English .\" .TH "UPSCODE2" "8" "04/26/2022" "Network UPS Tools 2\&.8\&.0" "NUT Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .\" http://bugs.debian.org/507673 .\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" ----------------------------------------------------------------- .\" * set default formatting .\" ----------------------------------------------------------------- .\" disable hyphenation .nh .\" disable justification (adjust text to left margin only) .ad l .\" ----------------------------------------------------------------- .\" * MAIN CONTENT STARTS HERE * .\" ----------------------------------------------------------------- .SH "NAME" upscode2 \- Driver for UPScode II compatible UPS equipment .SH "NOTE" .sp This man page only documents the hardware\-specific features of the upscode2 driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&. .SH "SUPPORTED HARDWARE" .sp This driver supports UPS equipment which can be controlled via the UPScode II protocol\&. This is mainly Fiskars, Powerware equipment, but also some (probably OEM\(cqed) products from Compaq\&. .SH "EXTRA ARGUMENTS" .sp This driver supports the following optional settings in the \fBups.conf\fR(5): .PP \fBmanufacturer\fR=\fIvalue\fR .RS 4 Autodetection of this parameter is not possible yet (and it probably never will be)\&. Therefore, this user\-defined string accepts any name\&. The default is \fIunknown\fR\&. .RE .PP \fBinput_timeout\fR=\fIvalue\fR .RS 4 The timeout waiting for a response from the UPS\&. Some UPS models have shown to be rather slow, resulting in frequent messages about empty responses from the UPS\&. If you see this, try increasing this value\&. .RE .PP \fBoutput_pace\fR=\fIvalue\fR .RS 4 Delay between characters sent to the UPS\&. This was added for completeness with the above parameter\&. It has not shown to be needed yet\&. .RE .PP \fBbaudrate\fR=\fIvalue\fR .RS 4 The default baudrate is 1200, which is the standard for the UPScode II protocol\&. .RE .PP \fBfull_update_timer\fR=\fIvalue\fR .RS 4 Number of seconds between collection of normative values\&. .RE .PP \fBuse_crlf\fR .RS 4 Flag to set if commands towards to UPS need to be terminated with CR\-LF, and not just CR\&. .RE .PP \fBuse_pre_lf\fR .RS 4 Flag to set if commands towards to UPS need to be introduced with an LF\&. A Compaq T1500h is known to need this\&. .RE .SH "COMMANDS" .sp The driver supports the following commands for those UPSes that support them\&. The available commands are autodetected during initialization, so you should check availability with \fIupscmd \-l\fR\&. .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} test\&.panel\&.start \- Start UPS self test .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} test\&.battery\&.start \- Start battery self test .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} beeper\&.enable \- Enable UPS beeper .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} beeper\&.disable \- Disable UPS beeper .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} shutdown\&.return \- Shut down in 1 second and wait for power to return .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} shutdown\&.stayoff \- Shut down in 1 seconds .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} shutdown\&.reboot \- Shut down in 1 seconds and reboot after 1 minute .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} shutdown\&.reboot\&.graceful \- Shut down in 20 seconds and reboot after 1 minute .RE .SH "NOTES" .sp The Powerware UPS models that this driver has been tested against until now have not returned a value for \fIbattery\&.charge\fR\&. Therefore, the driver will guestimate a value based on the nominal battery min/max and the current battery voltage\&. .SH "AUTHORS" .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} HÃ¥vard Lygre .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Niels Baggesen .RE .SH "SEE ALSO" .SS "The core driver:" .sp \fBnutupsdrv\fR(8) .SS "Internet resources:" .sp The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/