.TH snmp\-ups 8 "Fri May 15 2009" "" "Network UPS Tools (NUT)" .SH NAME snmp\(hyups \- Multi\(hyMIB Driver for SNMP UPS equipment .SH NOTE This man page only documents the hardware\(hyspecific features of the snmp\(hyups driver. For information about the core driver, see \fBnutupsdrv\fR(8). .SH SUPPORTED HARDWARE The snmp\(hyups driver automatically detects and supports a wide range of devices by loading various MIBS: .IP "ietf:" UPS that is RFC 1628 (UPS MIB) compliant, ie MGE UPS SYSTEMS, Liebert, perhaps others (default) .IP "mge:" MGE UPS SYSTEMS and MGE Office Protection Systems devices with SNMP cards (ref 66062, 66045, 66074 and 66244) .IP "apcc:" APC AP9606 APC Web/SNMP management card, perhaps others .IP "netvision:" Socomec Sicon UPS with Netvision Web/SNMP management card/external box .IP "pw:" Powerware devices with ConnectUPS SNMP cards .IP "aphel_genesisII:" Eaton Powerware ePDU Monitored .IP "aphel_revelation:" Eaton Powerware ePDU Managed .IP "raritan:" Various Raritan PDUs .IP "baytech:" Various BayTech PDUs .IP "cpqpower:" HP/Compaq AF401A management card, perhaps others .SH EXTRA ARGUMENTS This driver supports the following optional settings in the \fBups.conf\fR(5): .IP "mibs=\fIname\fR" Set MIB compliance (default=auto, allowed entries: refer to the above SUPPORTED HARDWARE). With auto the driver will try a select set of objets until it finds one that the device responds to. .IP "community=\fIname\fR" Set community name (default = public). Note that you require a RW community name to perform UPS settings (as for a powerdown). .IP "snmp_version=\fIversion\fR" Set SNMP version (default = v1, the other allowed value is v2c) .IP "pollfreq=\fIvalue\fR" Set polling frequency in seconds, to reduce network flow (default=30) .IP "notransferoids" Disable the monitoring of the low and high voltage transfer OIDs in the hardware. This will remove input.transfer.low and input.transfer.high from the list of variables. This should only be used on APCC Symmetra equipment which has strangeness in the three\(hyphase power reporting. .SH REQUIREMENTS You will need to install the Net\(hySNMP package from http://www.net\(hysnmp.org/ before building this driver. .SH LIMITATION .SS Shutdown This driver does not provide a proper upsdrv_shutdown() function. There probably never will be one, since at the time this script should run (near the end of the system halt script), there will be no network capabilities anymore. Probably the only way to shutdown an SNMP UPS is by sending it a shutdown with delay command through \fBupscmd\fR(8) and hope for the best that the system will have finished shutting down before the power is cut. .SH INSTALLATION This driver is only built if the Net SNMP development files are present on the system. You can also force it to be built by using "configure \-\-with\-snmp=yes" before calling make. .SH IMPLEMENTATION The hostname of the UPS is specified with the "port" value in \fBups.conf\fR, i.e.: .nf [snmp] driver = snmp\-ups port = snmp\-ups.example.com community = public snmp_version = v1 mibs = ietf pollfreq = 15 .fi .SH AUTHORS Arnaud Quette, Dmitry Frolov Sponsored by Eaton and originally by MGE UPS SYSTEMS .SH SEE ALSO .SS The core driver: \fBnutupsdrv\fR(8) .SS NUT SNMP Protocols Library Available at: http://random.networkupstools.org/protocols/snmp/ .SS Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/