APCUPSD-UPS(8) ============== NAME ---- apcupsd-ups - Driver for apcupsd client access NOTE ---- This man page only documents the specific features of the *apcupsd-ups* driver. For information about the core driver, see linkman:nutupsdrv[8]. DESCRIPTION ----------- This driver is a client to *apcupsd*. *apcupsd-ups* acts as an *apcupsd* client, simply forwarding data. This can be useful in cases where both protocols are required in a network, or in case apcupsd has a required UPS access mode missing from NUT. EXTRA ARGUMENTS --------------- This driver supports the following optional settings in linkman:nut.conf[5]: *port*=[:]:: This is the name of a remote host running apcupsd (plus an optional port). For instance: [apcupsd] driver = apcupsd-ups port = localhost desc = "apcupsd client" BACKGROUND ---------- This driver was originally written in one evening to allow interworking with *apcupsd*. SUPPORTED VARIABLES ------------------- The following variables are translated from *apcupsd* to NUT. All times should be converted to seconds (please file a bug if you notice a mismatch in units). [width="50%",cols="m,m",options="header"] |=============================== | apcupsd variable | NUT variable(s) | BCHARGE | battery.charge | MBATTCHG | battery.charge.low | RETPCT | battery.charge.restart | BATTDATE | battery.date | TIMELEFT | battery.runtime | MINTIMEL | battery.runtime.low | BATTV | battery.voltage | NOMBATTV | battery.voltage.nominal | LINEFREQ | input.frequency | SENSE | input.sensitivity | HITRANS | input.transfer.high | LOTRANS | input.transfer.low | LASTXFER | input.transfer.reason | LINEV | input.voltage | MAXLINEV | input.voltage.maximum | MINLINEV | input.voltage.minimum | NOMINV | input.voltage.nominal | LINEFREQ | output.frequency | OUTPUTV | output.voltage | NOMOUTV | output.voltage.nominal | DATE | ups.date, ups.time | DSHUTD | ups.delay.shutdown | DWAKE | ups.delay.start | FIRMWARE | ups.firmware, ups.firmware.aux | UPSNAME | ups.id | LOADPCT | ups.load | MANDATE | ups.mfr.date | NOMPOWER | ups.realpower.nominal | SERIALNO | ups.serial | STATUS | ups.status | ITEMP | ups.temperature | STESTI | ups.test.interval | SELFTEST | ups.test.result |=============================== LIMITATIONS ----------- Access to *apcupsd* is strictly read only: no commands can be issued. This stems from the design of *apcupsd*, where the settings are changed in *apctest*. In order to run *apctest*, *apcupsd* must be stopped (and *apcupsd* exposes the UPS to the network). AUTHOR ------ Andreas Steinmetz SEE ALSO -------- linkman:ups.conf[5], linkman:nutupsdrv[8] Internet Resources: ~~~~~~~~~~~~~~~~~~~ The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ The apcupsd home page: http://www.apcupsd.org/