#! /bin/sh ### BEGIN INIT INFO # Provides: nut-client upsmon ups-monitor # Required-Start: $local_fs $syslog $network $remote_fs # Required-Stop: $local_fs $syslog $network $remote_fs # Should-Start: nut-server # Should-Stop: # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: Network UPS Tools monitor initscript # Description: This script take care of starting and stopping the # Network UPS Tools monitoring component (upsmon). ### END INIT INFO # Author: Arnaud Quette PATH=/sbin:/usr/sbin:/bin:/usr/bin:/usr/local/sbin:/usr/local/bin NAME=nut-client DESC="Network UPS Tools - power device monitor and shutdown controller" CONFIG=/etc/nut/nut.conf pid_dir=/var/run/nut upsmon_pid=${pid_dir}/upsmon.pid upsmon=/sbin/upsmon log=">/dev/null 2>/dev/null" # Define LSB log_* functions. # Depend on lsb-base (>= 3.0-6) to ensure that this file is present. . /lib/lsb/init-functions # set upsmon specific options. use "man upsmon" for more info # this parameter is now located in nut.conf, and not in /etc/default/nut anymore # FIXME: retrieved from 'nut' script during update UPSMON_OPTIONS="" # Exit if the package is not installed [ -x "$upsmon" ] || exit 0 # Include NUT nut.conf [ -r $CONFIG ] && . $CONFIG # FIXME: put all common bits, between nut-client and nut-server, # into a common nut-function # Explicitly require the configuration to be done in /etc/nut/nut.conf if [ "x$MODE" = "xnone" -o -z "$MODE" ] ; then log_action_msg "$NAME disabled, please adjust the configuration to your needs" log_action_msg "Then set MODE to a suitable value in $CONFIG to enable it" # exit success to avoid breaking the install process! exit 0 fi # Check if /var/run/nut exists and has the correct perms check_var_directory() { [ ! -d ${pid_dir} ] && mkdir -p ${pid_dir} \ && chown root:nut ${pid_dir} \ && chmod 770 ${pid_dir} } # check if the right components are running check_status() { case "$MODE" in standalone|netserver|netclient) status_of_proc -p $upsmon_pid $upsmon upsmon ;; none|*) ;; esac } start_stop_client () { case "$MODE" in standalone|netserver|netclient) # FIXME: for standalone|netserver, ensure 'nut-server status' returns ? case "$1" in start) start-stop-daemon -S -q -p $upsmon_pid -x $upsmon \ -- $UPSMON_OPTIONS >/dev/null 2>&1 && log_progress_msg "upsmon" || log_progress_msg "(upsmon failed)" ;; stop) start-stop-daemon -K -o -q -p $upsmon_pid -n upsmon >/dev/null 2>&1 && log_progress_msg "upsmon" || log_progress_msg "(upsmon failed)" ;; esac ;; none|*) return 1 ;; esac } case "$1" in start) log_daemon_msg "Starting $DESC" check_var_directory start_stop_client start #&& log_progress_msg "upsmon" log_end_msg 0 ;; stop) log_daemon_msg "Stopping $DESC" start_stop_client stop && log_progress_msg "upsmon" log_end_msg 0 ;; reload) $upsmon -c reload >/dev/null 2>&1 ;; restart|force-reload) # FIXME: lack consistency, due to initscript split. # This only addresses partial reload. # Full reload requires to: # - stop nut-client # - restart (Ie stop+start) nut-server # - start nut-client log_daemon_msg "Restarting $DESC" start_stop_client stop # should then 'start_stop_server stop', Ie /etc/init.d/nut-server stop #sleep 5 check_var_directory # should first 'start_stop_server start', Ie /etc/init.d/nut-server start start_stop_client start && log_progress_msg "upsmon" log_end_msg 0 ;; status) #log_daemon_msg "Checking status of $DESC" echo "Checking status of $DESC" check_status exit $? ;; poweroff) case "$MODE" in standalone|netserver) # Sanity check flag=`sed -ne 's#^ *POWERDOWNFLAG *\(.*\)$#\1#p' /etc/nut/upsmon.conf` if [ -z "$flag" ] ; then log_action_msg "##########################################################" log_action_msg "## POWERDOWNFLAG is not defined in /etc/nut/upsmon.conf ##" log_action_msg "## ##" log_action_msg "## Please read the Manual page upsmon.conf(5) ##" log_action_msg "##########################################################" exit 1 fi # Defer to nut-server to actually poweroff the UPS, if needed if $upsmon -K >/dev/null 2>&1 ; then log_daemon_msg "UPS poweroff required..." log_end_msg 0 if [ -x /etc/init.d/nut-server ] ; then exec /etc/init.d/nut-server poweroff else log_action_msg "Failure: /etc/init.d/nut-server script missing" fi else log_action_msg "Power down flag is not set (UPS poweroff not needed)" fi ;; none|netclient|*) # nothing to do log_action_msg "'$MODE' configuration does not require UPS poweroff" ;; esac ;; *) N=/etc/init.d/$NAME echo "Usage: $N {start|stop|reload|restart|force-reload|status|poweroff}" >&2 exit 1 ;; esac exit 0