/* apcsmart_tabs.c - common tables for APC smart protocol units * * Copyright (C) 1999 Russell Kroll * (C) 2000 Nigel Metheringham * (C) 2011+ Michal Soltys * * This program is free software; you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by * the Free Software Foundation; either version 2 of the License, or * (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program; if not, write to the Free Software * Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA */ #include "apcsmart_tabs.h" /* APC_MULTI variables *must* be listed in order of preference */ apc_vartab_t apc_vartab[] = { { "ups.temperature", 'C', APC_POLL|APC_F_CELSIUS }, { "ups.load", 'P', APC_POLL|APC_F_PERCENT }, { "ups.test.interval", 'E', APC_F_HOURS }, { "ups.test.result", 'X', APC_POLL }, { "ups.delay.start", 'r', APC_F_SECONDS }, { "ups.delay.shutdown", 'p', APC_F_SECONDS }, { "ups.id", 'c', APC_STRING }, { "ups.contacts", 'i', APC_POLL|APC_F_HEX }, { "ups.display.language", '\014' }, { "input.voltage", 'L', APC_POLL|APC_F_VOLT }, { "input.frequency", 'F', APC_POLL|APC_F_DEC }, { "input.sensitivity", 's', }, { "input.quality", '9', APC_POLL|APC_F_HEX }, { "input.transfer.low", 'l', APC_F_VOLT }, { "input.transfer.high", 'u', APC_F_VOLT }, { "input.transfer.reason", 'G', APC_POLL|APC_F_REASON }, { "input.voltage.maximum", 'M', APC_POLL|APC_F_VOLT }, { "input.voltage.minimum", 'N', APC_POLL|APC_F_VOLT }, { "output.current", '/', APC_POLL|APC_F_AMP }, { "output.voltage", 'O', APC_POLL|APC_F_VOLT }, { "output.voltage.nominal", 'o', APC_F_VOLT }, { "ambient.humidity", 'h', APC_POLL|APC_F_PERCENT }, { "ambient.0.humidity", 'H', APC_POLL|APC_PACK|APC_F_PERCENT }, { "ambient.0.humidity.high", '{', APC_POLL|APC_PACK|APC_F_PERCENT }, { "ambient.0.humidity.low", '}', APC_POLL|APC_PACK|APC_F_PERCENT }, { "ambient.temperature", 't', APC_POLL|APC_F_CELSIUS }, { "ambient.0.temperature", 'T', APC_MULTI|APC_POLL|APC_PACK|APC_F_CELSIUS, "^[0-9]{2}\\.[0-9]{2}$" }, { "ambient.0.temperature.high", '[', APC_POLL|APC_PACK|APC_F_CELSIUS }, { "ambient.0.temperature.low", ']', APC_POLL|APC_PACK|APC_F_CELSIUS }, { "battery.date", 'x', APC_STRING }, { "battery.charge", 'f', APC_POLL|APC_F_PERCENT }, { "battery.charge.restart", 'e', APC_F_PERCENT }, { "battery.voltage", 'B', APC_POLL|APC_F_VOLT }, { "battery.voltage.nominal", 'g', }, { "battery.runtime", 'j', APC_POLL|APC_F_MINUTES }, { "battery.runtime.low", 'q', APC_F_MINUTES }, { "battery.packs", '>', APC_F_DEC }, { "battery.packs.bad", '<', APC_F_DEC }, { "battery.alarm.threshold", 'k', }, { "device.uptime", 'T', APC_MULTI|APC_POLL|APC_F_HOURS, "^[0-9]{3}\\.[0-9]{1}$" }, { "ups.serial", 'n', }, { "ups.mfr.date", 'm', }, { "ups.model", '\001' }, { "ups.firmware.aux", 'v', }, { "ups.firmware", 'b', APC_MULTI, "^[[:alnum:]]+\\.[[:alnum:]]+\\.[[:alnum:]]+$" }, { "ups.firmware", 'V', APC_MULTI }, { NULL } /* todo: I = alarm enable (hex field) - split into alarm.n.enable J = alarm status (hex field) - split into alarm.n.status 0x15 = output voltage selection (APC_F_VOLT) 0x5C = load power (APC_POLL|APC_F_PERCENT) */ }; /* * APC commands mapped to NUT's instant commands * the format of extra values is matched by extended posix regex * APC_CMD_CUSTOM means that the instant command is handled by separate * function, thus the actual APC cmd in the table is ignored */ apc_cmdtab_t apc_cmdtab[] = { { "shutdown.return", "^[Aa][Tt]:[0-9]{1,3}$", APC_CMD_GRACEDOWN, APC_NASTY }, { "shutdown.return", "^([Cc][Ss]|)$", APC_CMD_SOFTDOWN, APC_NASTY }, { "shutdown.stayoff", 0, APC_CMD_SHUTDOWN, APC_NASTY|APC_REPEAT }, { "load.off", 0, APC_CMD_OFF, APC_NASTY|APC_REPEAT }, { "load.on", 0, APC_CMD_ON, APC_REPEAT }, { "calibrate.start", 0, APC_CMD_CALTOGGLE, 0 }, { "calibrate.stop", 0, APC_CMD_CALTOGGLE, 0 }, { "test.panel.start", 0, APC_CMD_FPTEST, 0 }, { "test.failure.start", 0, APC_CMD_SIMPWF, 0 }, { "test.battery.start", 0, APC_CMD_BTESTTOGGLE, 0 }, { "test.battery.stop", 0, APC_CMD_BTESTTOGGLE, 0 }, { "bypass.start", 0, APC_CMD_BYPTOGGLE, 0 }, { "bypass.stop", 0, APC_CMD_BYPTOGGLE, 0 }, { NULL } }; /* compatibility with hardware that doesn't do APC_CMDSET ('a') */ apc_compattab_t apc_compattab[] = { /* APC Matrix */ { "0XI", "@789ABCDEFGKLMNOPQRSTUVWXYZcefgjklmnopqrsuwxz/<>\\^\014\026", 0 }, { "0XM", "@789ABCDEFGKLMNOPQRSTUVWXYZcefgjklmnopqrsuwxz/<>\\^\014\026", 0 }, { "0ZI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 }, { "5UI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 }, { "5ZM", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz/<>", 0 }, /* APC600 */ { "6QD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "6QI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "6TD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "6TI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, /* SmartUPS 900 */ { "7QD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "7QI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "7TD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "7TI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, /* SmartUPS 600I */ { "6JI", "@789ABCFGKLMNOPQSTUVWXYZfg", 0 }, /* SmartUPS 900I */ { "7II", "@79ABCEFGKLMNOPQRSUVWXYZcfg", 0 }, /* SmartUPS 2000I */ { "9II", "@79ABCEFGKLMNOPQRSUVWXYZcfg", 0 }, { "9GI", "@79ABCEFGKLMNOPQRSUVWXYZcfg", 0 }, /* SmartUPS 1250I */ { "8II", "@79ABCEFGKLMNOPQRSUVWXYZcfg", 0 }, { "8GI", "@79ABCEFGKLMNOPQRSUVWXYZfg", 0 }, /* SmartUPS 1250 */ { "8QD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "8QI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "8TD", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, { "8TI", "@79ABCDEFGKLMNOPQRSUVWXYZcefgjklmnopqrsuxz", 0 }, /* CS 350 */ { "5.4.D", "@\1ABPQRSUYbdfgjmnx9", 0 }, /* * certain set of UPSes returning voltage > 255V through 'b'; "set\1" * is matched explicitly (fake key); among the UPS models - some old * APC 600 ones */ { "set\1", "@789ABCFGKLMNOPQRSUVWXYZ", 0 }, { NULL } }; upsdrv_info_t apc_tab_info = { "APC command table", APC_TABLE_VERSION };