@ -34,7 +34,53 @@ oneac \- Driver for Oneac UPS equipment
This man page only documents the hardware\-specific features of the oneac driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&.
.SH "SUPPORTED HARDWARE"
.sp
This driver supports Oneac EG and ON UPS equipment with the Advanced Interface\&. If your UPS is equipped with the Basic Interface card, use the genericups driver\&.
This driver supports various Oneac UPS families:
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
EG (late 80s, early 90s, plug\-in serial interface card)
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
ON (early and mid\-90s, plug\-in serial interface card)
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
OZ (mid\-90s on, DB\-25 std\&., interface slot)
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
OB (early 2000\(cqs on, big cabinet, DB\-25 std\&., interface slot)
.RE
.sp
If your UPS is equipped with the Basic Interface card, use the \fBgenericups\fR(8) driver\&.
.SH "EXTRA ARGUMENTS"
.sp
This driver supports the following optional settings in the \fBups.conf\fR(5) file:
@ -43,18 +89,39 @@ This driver supports the following optional settings in the \fBups.conf\fR(5) fi
.RS 4
Change battery test time from the 2 minute default\&.
.RE
.PP
\fBoffdelay\fR=\fInum\fR
.RS 4
Change shutdown delay time from 0 second default\&.
.RE
.SH "INSTANT COMMANDS"
.sp
This driver supports the following Instant Commands\&.
This driver supports the following Instant Commands\&. (See \fBupscmd\fR(8))
.SS "All UPS units"
.PP
\fBreset\&.input\&.minmax\fR
\fBshutdown\&.return\fR
.RS 4
Reset the minimum and maximum input line voltage values seen since the last reset or power on\&.
Turn off the load possibly after a delay and return when power is back\&.
.RE
.PP
\fBtest\&.battery\&.start\fR
\fBshutdown\&.stop\fR
.RS 4
Start a battery test\&. The default time is 2 minutes\&. This time can be set in the
Stop a shutdown in progress\&.
.RE
.PP
\fBshutdown\&.reboot\fR
.RS 4
Shut down the load briefly while rebooting the UPS\&.
.RE
.PP
\fBtest\&.failure\&.start\fR
.RS 4
Starts a 15 second long simulation of an input power failure\&.
.RE
.PP
\fBtest\&.battery\&.start\&.quick\fR
.RS 4
Start a "quick" battery test\&. The default time is 2 minutes\&. This time can be set in the
\fBups\&.conf\fR
file\&. See
\fBtestime\fR
@ -65,14 +132,81 @@ above\&.
.RS 4
Stops a battery test that is in progress\&.
.RE
.SS "All ON UPS units"
.PP
\fBtest\&.failure\&.start\fR
\fBreset\&.input\&.minmax\fR
.RS 4
Starts a 15 second long simulation of an input power failure\&.
Reset the minimum and maximum input line voltage values seen since the last reset or power on\&.
.RE
.SS "Newer ON UPS units"
.PP
\fBtest\&.panel\&.start\fR
.RS 4
Start testing the UPS panel\&.
.RE
.PP
\fBtest\&.battery\&.start\&.deep\fR
.RS 4
Start a "deep" battery test\&. This test runs the UPS until the low battery point and then returns to the AC line\&.
.RE
.PP
\fBreset\&.input\&.minmax\fR
.RS 4
Reset the minimum and maximum input line voltage values seen since the last reset or power on\&.
.RE
.PP
\fBbeeper\&.enable\fR
.RS 4
Enable UPS beeper/buzzer\&.
.RE
.PP
\fBbeeper\&.disable\fR
.RS 4
Disable UPS beeper/buzzer\&.
.RE
.PP
\fBbeeper\&.mute\fR
.RS 4
Mutes the UPS beeper/buzzer for the current alarm condition(s)\&.
.RE
.SH "WRITABLE VARIABLES"
.sp
See \fBupsrw\fR(8) to see what variables are writable for the UPS\&.
.if n \{\
.sp
.\}
.RS 4
.it 1 an-trap
.nr an-no-space-flag 1
.nr an-break-flag 1
.br
.ps +1
\fBNote\fR
.ps -1
.br
.sp
If your UPS supports writing battery\&.runtime\&.low, the new set value is to be entered in minutes (up to 99) but the reported value is reported in seconds (set value * 60)\&.
.sp .5v
.RE
.if n \{\
.sp
.\}
.RS 4
.it 1 an-trap
.nr an-no-space-flag 1
.nr an-break-flag 1
.br
.ps +1
\fBNote\fR
.ps -1
.br
.sp
If your UPS supports input\&.transfer\&.low and input\&.transfer\&.high, those values are used to create an allowable output range\&. The UPS will do what it can to keep the output voltage value within the defined range (for example: tap change or switch to inverter)\&.
.sp .5v
.RE
.SH "AUTHOR"
.sp
Eric Lawson <elawson@inficad\&.com>
Bill Elliot <bill@wreassoc\&.com>, Eric Lawson <elawson@inficad\&.com>
.SH "SEE ALSO"
.SS "The core driver:"
.sp