@ -1,13 +1,13 @@
'\" t
.\" Title: apcsmart
.\" Author: [see the "AUTHOR" section]
.\" Generator: DocBook XSL Stylesheets v1.76.1 <http://docbook.sf.net/>
.\" Date: 02/25/2014
.\" Generator: DocBook XSL Stylesheets v1.78.1 <http://docbook.sf.net/>
.\" Date: 04/17/2015
.\" Manual: NUT Manual
.\" Source: Network UPS Tools 2.7.1.5
.\" Source: Network UPS Tools 2.7.3
.\" Language: English
.\"
.TH "APCSMART" "8" "02/25/2014" "Network UPS Tools 2\&.7\&.1\&." "NUT Manual"
.TH "APCSMART" "8" "04/17/2015" "Network UPS Tools 2\&.7\&.3" "NUT Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
@ -33,7 +33,7 @@ apcsmart \- Driver for American Power Conversion Smart Protocol UPS equipment
.sp
\fBapcsmart\fR \-h
.sp
\fBapcsmart\fR \-a \*(AqUPS_NAME\*(Aq [\-x option=value \&...]
\fBapcsmart\fR \-a \fIUPS_NAME\fR [\-x option=value \&...]
.if n \{\
.sp
.\}
@ -52,15 +52,15 @@ This man page only documents the hardware\-specific features of the apcsmart dri
.RE
.SH "SUPPORTED HARDWARE"
.sp
The apcsmart driver should recognize (or at the very least work with) majority of Smart\-UPS models \- which includes Smart\-UPS, Matrix\-UPS and Back\-UPS lineups, among few other ones\&.
The apcsmart driver should recognize (or at the very least, work with) the majority of Smart\-UPS models \- which includes Smart\-UPS, Matrix\-UPS and Back\-UPS lineups, among few other ones\&.
.sp
Currently we can roughly divide APC hardware into 3 groups (note that the division isn\*(Aqt strict by any means, and the borders between those are pretty fuzzy):
Currently, we can roughly divide APC hardware into four groups (note that the division isn\(cqt strict by any means, and the borders between those are pretty fuzzy):
.PP
[very] "old" models
.RS 4
These models usually have old APC logo, white color and
\fIno\fR
programmable eeprom; You won\*(Aqt find them listed anywhere on APC\(cqs site either\&. The support for those will be usually based on driver\*(Aqs compatibility tables, or if the model (firmware) is not listed in those \- the driver will try to follow the very basic subset of features, while still trying to remain useful\&. Despite "smart" tagname, they often tend to behave in pretty dumb way (see the section below about shutdown behaviour)\&.
programmable EEPROM; you won\(cqt find them listed anywhere on APC\(cqs site either\&. The support for those will be usually based on driver\(cqs compatibility tables, or if the model (firmware) is not listed in those \- the driver will try to follow the very basic subset of features, while still trying to remain useful\&. Despite "smart" tagname, they often tend to behave in pretty dumb way (see the section below about shutdown behaviour)\&.
.PP
\fBExample models:\fR
.sp
@ -89,16 +89,52 @@ Smart\-UPS 900I
.PP
"new" models
.RS 4
These models usually come from late 1990s / pre\-2009 times\&. They are often referred as "3rd\&. gen"\&. For the most part, they have programmable eeprom, report supported commands and capabilites, and should work just fine with the apcsmart driver\&.
These models usually come from late 1990s / pre\-2009 times\&. They are often referred as "3rd\&. gen"\&. For the most part, they have programmable EEPROM, report supported commands and capabilites, and should work just fine with the apcsmart driver\&.
.RE
.PP
"microlink" models
.RS 4
WARNING: these are not
\fInatively\fR
supported by apcsmart (or apcupsd for that matter, if you\(cqre wondering)\&. Around 2007 APC (now APC Schneider) decided to go back to its proprietry roots and all the new models (SMT, SMX, SURTD) use completely different protocol and cables\&. If you purchased a new APC UPS, that uses cable with rj45 on the one end, and db\-9 on the other \- then you have such model\&. Your only option to support it through
supported by
\fBapcsmart\fR
(or
\fBapcupsd\fR, for that matter, if you\(cqre wondering)\&. Around 2007, APC (now APC Schneider) decided to go back to its proprietry roots, and all the new models (SMT, SMX, SURTD) use completely different protocol and cables\&. If you purchased a new APC UPS \- that uses cable with RJ45 on the one end, and DB\-9 on the other \- then you have such model\&. Your only option to support it through
\fBNUT\fR
is to purchase "legacy communications card" \- part #AP9620 (google \*(AqAP9620\*(Aq for more details)\&. Or if that\*(Aqs not an option, rely on official software\&.
is to purchase a "legacy communications card" \- part #AP9620 (google \*(AqAP9620\*(Aq for more details)\&. Or if that\(cqs not an option, rely on official software\&.
.RE
.PP
Microsol models
.RS 4
Several Microsol serial models sold in Brazil have been rebranded as APC Back\-UPS, and the model numbers tend to start with "BZ"\&. If you have one of these "Nobreaks", they will not work with the
\fBapcsmart\fR
driver \- please see the
\fBsolis\fR(8)
driver instead\&.
.PP
\fBExample models:\fR
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Back\-UPS BZ1200\-BR
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Back\-UPS BZ2200BI\-BR
.RE
.RE
.sp
Another thing to remember is that Smart protocol is not USB protocol\&. If you have UPS with both USB and serial ports, then depending on how you connect it, you will need either apcsmart or usbhid\-ups driver\&.
@ -135,7 +171,7 @@ Alternatively, you can also provide it on the command line using:
\-x \fBcable\fR=940\-0095B
.SH "TTY MODES"
.sp
By default the driver works in canonical mode, but it showed to be a problem in windows systems\&. Furthermore there\(cqs a possibility of some obscure serial cards or serial\-usb convertes that could cause problems as well\&. You can use \*(Aqttymode=\*(Aq option to force non\-canonical discipline in \fBups.conf\fR(5):
By default the driver works in canonical mode, but it proved to be a problem in Windows systems\&. Furthermore there\(cqs a possibility of some obscure serial cards or serial\-USB converters that could cause problems as well\&. You can use \*(Aqttymode=\*(Aq option to force non\-canonical discipline in \fBups.conf\fR(5):
.sp
\fBttymode\fR=raw
.sp
@ -165,7 +201,7 @@ APC hardware supports a lot of shutdown methods, that themselves can differ in b
\fBS\fR (soft hibernate)
.RS 4
This is most basic command present in probably all APC models\&. It will hibernate the UPS, and subsequently wake it up when the mains supply returns\&.
\fBThe command doesn\*(Aqt work if UPS is running on mains\&.\fR
\fBThe command doesn\(cqt work if the UPS is running on mains\&.\fR
.PP
"old" models
.RS 4
@ -174,7 +210,7 @@ The behaviour here is unfortunately pretty primitive \- when the power returns,
.PP
"new" models
.RS 4
The behaviour here is as expected \- the power is cut off after the eeprom defined grace period\&. The UPS will wake up when the power returns, after the eeprom defined delay AND if the eeprom defined min\&. battery charge level is met\&. The delay is counted from the power\*(Aqs return\&.
The behaviour here is as expected \- the power is cut off after the EEPROM defined grace period\&. The UPS will wake up when the power returns, after the EEPROM defined delay AND if the EEPROM defined min\&. battery charge level is met\&. The delay is counted from the power\*(Aqs return\&.
.RE
.RE
.PP
@ -206,8 +242,8 @@ If nnn = 000, then UPS will do precisely nothing\&. On those models you\*(Aqre b
.PP
"new" models
.RS 4
All the usual variables defined in eeprom are respected (see
\fBS\fR)\&. Additionally, if nnn > 0, the nnn*6 minutes are added to eeprom defined delay\&. UPS will not power up if it\*(Aqs running on batteries, contrary to what "old" models used to do \- the combined delay is counted from the moment of power return\&.
All the usual variables defined in EEPROM are respected (see
\fBS\fR)\&. Additionally, if nnn > 0, the nnn*6 minutes are added to EEPROM defined delay\&. UPS will not power up if it\*(Aqs running on batteries, contrary to what "old" models used to do \- the combined delay is counted from the moment of power return\&.
.RE
.sp
Supposedly there exist models that take 2 digits instead of 3\&. Just in case, NUT also supports such variation\&. You have to provide exactly 2 digits to trigger it (\fBawd\fR
@ -216,7 +252,7 @@ option, or argument to one of the supported instant commands)\&.
.PP
\fBK\fR (delayed poweroff)
.RS 4
This is permanent poweroff \- the UPS will not wake up automatically\&. On newer units, it will respect applicable eeprom variables\&.
This is permanent poweroff \- the UPS will not wake up automatically\&. On newer units, it will respect applicable EEPROM variables\&.
.RE
.PP
\fBZ\fR (instant poweroff)
@ -366,7 +402,7 @@ Hard hibernate\*(Aqs additional wakeup delay can be provided by \fBawd\fR\&.
.RE
.SH "IGNORING LB STATE"
.sp
APC units \- even if they report LB mode \- will not go into shutdown automatically\&. This gives us even more control with reference to "when to actually shutdown psu"\&. Since version 2\&.6\&.2, NUT supports \fBignorelb\fR option in driver\*(Aqs section of \fBups.conf\fR(5)\&. When such option is in effect, the core driver will ignore LB state as reported by specific driver and start shutdown basing the decision \fIonly\fR on two conditions:
APC units \- even if they report LB mode \- will not go into shutdown automatically\&. This gives us even more control with reference to "when to actually shutdown PSU"\&. Since version 2\&.6\&.2, NUT supports \fBignorelb\fR option in driver\(cqs section of \fBups.conf\fR(5)\&. When such option is in effect, the core driver will ignore LB state as reported by specific driver and start shutdown basing the decision \fIonly\fR on two conditions:
.sp
battery\&.charge < battery\&.charge\&.low
.sp
@ -376,7 +412,7 @@ battery\&.runtime < battery\&.runtime\&.low
.sp
Of course \- if any of the variables are not available, the appropriate condition is not checked\&. If you want to explicitly disable one of the conditions, simply override the right hand variable causing the condition to always evaluate to false (you can even provide negative numbers)\&.
.sp
APC UPSes don\*(Aqt have battery\&.charge\&.low \- you will have to define it if you want to use such condition (prefix the variable with override\&. or default\&.)\&.
APC UPSes don\(cqt have battery\&.charge\&.low \- you will have to define it if you want to use such condition (prefix the variable with override\&. or default\&.)\&.
.sp
"New" units have battery\&.runtime\&.low, but depending on battery quality, firmware version, calibration and UPS load \- this variable can be underestimated quite a bit \- especially right after going into OB state\&. This in turn can cause LB to be asserted, which under normal conditions will cause \fBNUT\fR to initiate the shutdown\&. You might want to disable this condition entirely, when relying on \fBignorelb\fR option (this was actually the main motivation behind introduction of such feature)\&.
.sp
@ -535,7 +571,7 @@ calibrate\&.stop
.RE
.SH "PREVIOUS DRIVER VERSION"
.sp
Previous driver is still available as apcsmart\-old \- should there be any need to use earlier version (bugs, incompatiblities with new functionality, etc\&.)\&. In due time apcsmart\-old will be phased out completely, but this won\(cqt happen until the new version gets solid exposure with no pending issues\&.
Previous driver is still available as \fBapcsmart\-old\fR, should there be any need to use earlier version (bugs, incompatiblities with new functionality, etc\&.)\&. In due time, \fBapcsmart\-old\fR will be phased out completely, but this won\(cqt happen until the new version gets solid exposure with no pending issues\&.
.SH "BUGS"
.sp
Some older APC UPS models return bogus data in the status register during a front panel test\&. This is usually detected and discarded, but some other unexpected values have occasionally slipped through\&.
@ -546,7 +582,7 @@ APC UPS models with both USB and serial ports require a power cycle when switchi
Nigel Metheringham <Nigel\&.Metheringham@Intechnology\&.co\&.uk> (drawing heavily on the original apcsmart driver by Russell Kroll)\&. This driver was called newapc for a time and was renamed in the 1\&.5 series\&. In 2\&.6\&.2 it was renamed to apcsmart\-old, being superseded by updated version with new features, which is maintained by Michal Soltys <soltys@ziu\&.info>
.SH "SEE ALSO"
.sp
\fBnutupsdrv\fR(8), \fBups.conf\fR(5)
\fBnutupsdrv\fR(8), \fBups.conf\fR(5), \fBusbhid-ups\fR(8), \fBsolis\fR(8)
.SS "Internet resources:"
.sp
The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/