Imported Upstream version 2.7.3
This commit is contained in:
parent
a356b56d11
commit
fd413a3168
283 changed files with 14978 additions and 6511 deletions
|
|
@ -55,7 +55,7 @@ Documents in this section are provided courtesy of Eaton.
|
|||
MGE Office Protection Systems
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The two first cables also applies to MGE UPS SYSTEMS.
|
||||
The three first cables also applies to MGE UPS SYSTEMS and Eaton.
|
||||
|
||||
DB9-DB9 cable (ref 66049)
|
||||
^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||
|
|
@ -67,11 +67,36 @@ image::images/cables/mge-66049.png[DB9-DB9 cable]
|
|||
DB9-RJ45 cable
|
||||
^^^^^^^^^^^^^^
|
||||
|
||||
This cable is used on the more recent models, including Ellipse MAX, Protection
|
||||
Station, ...
|
||||
This cable is used on the more recent models, including Ellipse MAX,
|
||||
Protection Station, ...
|
||||
|
||||
image::images/cables/mge-db9-rj45.jpg[DB9-RJ45 cable]
|
||||
|
||||
NMC DB9-RJ45 cable
|
||||
^^^^^^^^^^^^^^^^^^
|
||||
|
||||
The following applies to the MGE 66102 NMC (Network Management Card), and
|
||||
possibly other models. The NMC connection is an 8P8C RJ45-style jack.
|
||||
|
||||
|====
|
||||
|Signal | PC | NMC
|
||||
| | 1,4,6 |
|
||||
|TxD | 2 | 3
|
||||
|RxD | 3 | 6
|
||||
|GND | 5 | 4
|
||||
| | 7,8 |
|
||||
| | shield | shield
|
||||
|====
|
||||
|
||||
|
||||
USB-RJ45 cable
|
||||
^^^^^^^^^^^^^^
|
||||
|
||||
This cable is used also on the more recent models, including Ellipse MAX,
|
||||
Protection Station, ...
|
||||
|
||||
image::images/cables/mge-usb-rj45.jpg[USB-RJ45 cable]
|
||||
|
||||
DB9-RJ12 cable
|
||||
^^^^^^^^^^^^^^
|
||||
|
||||
|
|
@ -104,17 +129,37 @@ T700, T1000, T1500, T1500j, T700h, T1000h, T1500h, R1500, R1500j,
|
|||
R1500h, T2000, T2000j, T2400h, T2400h-NA, R3000 / R3000j, R3000h,
|
||||
R3000h-International, R3000h-NA, R6000h-NA, R6000i, R6000j.
|
||||
|
||||
UPS PC 9 pin connector
|
||||
UPS PC 9 pin connector
|
||||
|
||||
1 --------- 3
|
||||
2 --------- 2
|
||||
4 -\
|
||||
4 --------- 5 |
|
||||
6 -/
|
||||
6 --------- 7
|
||||
1 --------- 3
|
||||
2 --------- 2
|
||||
4 -\
|
||||
4 --------- 5 |
|
||||
6 -/
|
||||
6 --------- 7
|
||||
|
||||
Contributed by Kjell Claesson and Arnaud Quette.
|
||||
|
||||
Phoenixtec (Best Power)
|
||||
-----------------------
|
||||
|
||||
Many Best Power units (including the Patriot Pro II) have a female DB-9 socket
|
||||
with a non-standard pinout.
|
||||
|
||||
|====
|
||||
|Signal | PC | UPS
|
||||
| | 1,4,6 | NC
|
||||
|TxD | 2 | 2
|
||||
|RxD | 3 | 1
|
||||
|GND | 5 | 4
|
||||
| | 7,8 | NC
|
||||
|====
|
||||
|
||||
Sources:
|
||||
|
||||
* http://pinoutsguide.com/UPS/best_power_pinout.shtml
|
||||
* http://lit.powerware.com/ll_download.asp?file=m_patriotproii_jan99.pdf
|
||||
* Stan Gammons
|
||||
|
||||
Tripp-Lite
|
||||
----------
|
||||
|
|
|
|||
Loading…