Imported Upstream version 2.7.4

This commit is contained in:
Laurent Bigonville 2016-07-18 02:11:41 +02:00
parent fd413a3168
commit c9cb2187ee
290 changed files with 7473 additions and 2607 deletions

View file

@ -47,6 +47,11 @@ VARDESC input.voltage "Input voltage (V)"
VARDESC input.voltage.extended "Extended input voltage range"
VARDESC input.voltage.maximum "Maximum incoming voltage seen (V)"
VARDESC input.voltage.minimum "Minimum incoming voltage seen (V)"
VARDESC input.voltage.status "Voltage status relative to the thresholds"
VARDESC input.voltage.low.warning "Input voltage low warning threshold (V)"
VARDESC input.voltage.low.critical "Input voltage low critical threshold (V)"
VARDESC input.voltage.high.warning "Input voltage high warning threshold (V)"
VARDESC input.voltage.high.critical "Input voltage high critical threshold (V)"
VARDESC input.voltage.nominal "Nominal input voltage (V)"
VARDESC input.transfer.reason "Reason for last transfer to battery"
VARDESC input.transfer.low "Low voltage transfer point (V)"
@ -59,8 +64,14 @@ VARDESC input.sensitivity "Input power sensitivity"
VARDESC input.quality "Input power quality"
VARDESC input.current "Input current (A)"
VARDESC input.current.nominal "Nominal input current (A)"
VARDESC input.current.status "Current status relative to the thresholds"
VARDESC input.current.low.warning "Input current low warning threshold (A)"
VARDESC input.current.low.critical "Input current low critical threshold (A)"
VARDESC input.current.high.warning "Input current high warning threshold (A)"
VARDESC input.current.high.critical "Input current high critical threshold (A)"
VARDESC input.frequency "Input line frequency (Hz)"
VARDESC input.frequency.extended "Extended input frequency range"
VARDESC input.frequency.status "Frequency status"
VARDESC input.frequency.nominal "Nominal input line frequency (Hz)"
VARDESC input.frequency.low "Minimum input line frequency (Hz)"
VARDESC input.frequency.high "Maximum input line frequency (Hz)"
@ -72,6 +83,8 @@ VARDESC input.transfer.delay "Delay before transfer to mains"
VARDESC input.load "Load on (ePDU) input (percent of full)"
VARDESC input.realpower "Current sum value of all (ePDU) phases real power (W)"
VARDESC input.power "Current sum value of all (ePDU) phases apparent power (VA)"
VARDESC input.source "The current input power source"
VARDESC input.source.preferred "The prefered input power source"
VARDESC output.voltage "Output voltage (V)"
VARDESC output.voltage.nominal "Nominal output voltage (V)"
@ -106,14 +119,31 @@ VARDESC battery.charger.status "Battery charger status"
VARDESC ambient.temperature "Ambient temperature (degrees C)"
VARDESC ambient.temperature.alarm "Ambient temperature alarm is active"
VARDESC ambient.temperature.alarm.maximum "Maximum allowed ambient temperature"
VARDESC ambient.temperature.alarm.minimum "Minimum allowed ambient temperature"
VARDESC ambient.temperature.status "Ambient temperature status relative to the configured thresholds"
VARDESC ambient.temperature.alarm.maximum "Maximum allowed ambient temperature (degrees C)"
VARDESC ambient.temperature.alarm.minimum "Minimum allowed ambient temperature (degrees C)"
VARDESC ambient.temperature.alarm.enable "Enable ambient temperature alarm"
VARDESC ambient.humidity "Ambient humidity"
VARDESC ambient.temperature.low "Temperature threshold low (degrees C)"
VARDESC ambient.temperature.low.warning "Temperature threshold low warning (degrees C)"
VARDESC ambient.temperature.low.critical "Temperature threshold low critical (degrees C)"
VARDESC ambient.temperature.high "Temperature threshold high (degrees C)"
VARDESC ambient.temperature.high.warning "Temperature threshold high warning (degrees C)"
VARDESC ambient.temperature.high.critical "Temperature threshold high critical (degrees C)"
VARDESC ambient.humidity "Ambient humidity (percent)"
VARDESC ambient.humidity.alarm "Ambient humidity alarm is active"
VARDESC ambient.humidity.alarm.maximum "Maximum allowed ambient humidity"
VARDESC ambient.humidity.alarm.minimum "Minimum allowed ambient humidity"
VARDESC ambient.humidity.status "Ambient humidity status relative to the configured thresholds"
VARDESC ambient.humidity.alarm.maximum "Maximum allowed ambient humidity (percent)"
VARDESC ambient.humidity.alarm.minimum "Minimum allowed ambient humidity (percent)"
VARDESC ambient.humidity.alarm.enable "Enable ambient humidity alarm"
VARDESC ambient.humidity.low "Ambient humidity threshold low (percent)"
VARDESC ambient.humidity.low.warning "Ambient humidity threshold low warning (percent)"
VARDESC ambient.humidity.low.critical "Ambient humidity threshold low critical (percent)"
VARDESC ambient.humidity.high "Ambient humidity threshold high (percent)"
VARDESC ambient.humidity.high.warning "Ambient humidity threshold high warning (percent)"
VARDESC ambient.humidity.high.critical "Ambient humidity threshold high critical (percent)"
VARDESC ambient.present "Ambient sensor presence"
VARDESC ambient.contacts.1.status "State of the dry contact sensor 1"
VARDESC ambient.contacts.2.status "State of the dry contact sensor 2"
# FIXME: the outlet collection is indexed - solve with regexs?
#