Imported Upstream version 2.6.1
This commit is contained in:
parent
459aaf9392
commit
a367d9bc54
178 changed files with 4651 additions and 3279 deletions
|
|
@ -74,6 +74,22 @@ static info_lkp_t cps_battvolt[] = {
|
|||
{ 0, NULL, &cps_battvolt_fun }
|
||||
};
|
||||
|
||||
/* returns statically allocated string - must not use it again before
|
||||
done with result! */
|
||||
static const char *cps_battcharge_fun(double value)
|
||||
{
|
||||
static char buf[8];
|
||||
|
||||
/* clamp battery charge to 100% */
|
||||
snprintf(buf, sizeof(buf), "%.0f", value < 100.0 ? value : 100.0);
|
||||
|
||||
return buf;
|
||||
}
|
||||
|
||||
static info_lkp_t cps_battcharge[] = {
|
||||
{ 0, NULL, &cps_battcharge_fun }
|
||||
};
|
||||
|
||||
/* --------------------------------------------------------------- */
|
||||
/* Vendor-specific usage table */
|
||||
/* --------------------------------------------------------------- */
|
||||
|
|
@ -106,7 +122,7 @@ static hid_info_t cps_hid2nut[] = {
|
|||
{ "battery.mfr.date", 0, 0, "UPS.PowerSummary.iOEMInformation", NULL, "%s", 0, stringid_conversion },
|
||||
{ "battery.charge.warning", 0, 0, "UPS.PowerSummary.WarningCapacityLimit", NULL, "%.0f", 0, NULL },
|
||||
{ "battery.charge.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.RemainingCapacityLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
||||
{ "battery.charge", 0, 0, "UPS.PowerSummary.RemainingCapacity", NULL, "%.0f", 0, NULL },
|
||||
{ "battery.charge", 0, 0, "UPS.PowerSummary.RemainingCapacity", NULL, "%s", 0, cps_battcharge },
|
||||
{ "battery.runtime", 0, 0, "UPS.PowerSummary.RunTimeToEmpty", NULL, "%.0f", 0, NULL },
|
||||
{ "battery.runtime.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.RemainingTimeLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL },
|
||||
{ "battery.voltage.nominal", 0, 0, "UPS.PowerSummary.ConfigVoltage", NULL, "%.0f", 0, NULL },
|
||||
|
|
|
|||