@ -24,84 +24,85 @@ This driver supports the following optional settings in the
linkman:ups.conf[5] file:
*linevoltage*='value'::
An integer specifying the mains voltage. It can't be auto detected.
Acceptable values are in the range of 110--120 or 220--240. The default
is '230'.
An integer specifying the line voltage. It can't be auto detected. Acceptable
values are in the range of 110-120 or 220-240. The default is '230'.
*manufacturer*='name'::
Specify the manufacturer name, which also can't be auto detected. This is
a user defined string, so any name is acceptable. The default is
'PowerCom'.
Specify the manufacturer name, which also can't be auto detected. This is a
user defined string, so any name is acceptable. The default is 'PowerCom'.
*modelname*='name'::
Specify the model name, which also can't be auto detected. This is a
user defined string, so any name is acceptable. The default is
'Unknown'.
Specify the model name, which also can't be auto detected. This is a user
defined string, so any name is acceptable. The default is 'Unknown'.
*serialnumber*='value'::
Like modelname above, but for the serial number. The default is
'Unknown'.
Like modelname above, but for the serial number. The default is 'Unknown'.
*type*='name'::
The exact type of the communication protocol within the powercom family,
that will be used to communicate with the UPS. The type is named after
the first modelname that was coded with that protocol. The acceptable
names are 'KP625AP', 'Trust', 'Egys', 'KIN', 'BNT', 'IMP' and 'BNT-other'. The
default is 'Trust'.
The exact type of the communication protocol within the powercom family, that
will be used to communicate with the UPS. The type is named after the first
modelname that was coded with that protocol. The acceptable names are
'Trust', 'Egys', 'KP625AP', 'IMP', 'KIN', 'BNT', and 'BNT-other'.
The default is 'Trust'.
+
'BNT-other' is a special type for BNT 100-120V models.
For this type you can (I think must!) specify voltage, batteryPercentage,
loadPercentage and validationSequence.
*numOfBytesFromUPS*='value'::
The number of bytes in a UPS frame. The default is type-dependent and
is given below.
*methodOfFlowControl*='name'::
The method of serial communication flow control that is engaged by the
UPS. The default is type-dependent and is given below. Acceptable names
are 'dtr0rts1', 'dtr1' or 'no_flow_control'.
'BNT-other' is a special type for other BNT models (such as the 1500A at 120V
and can be used to override ALL models using ALL of the following values.
*shutdownArguments*={{'minutes','seconds'},'whether_minutes_should_be_used'}::
The minutes and seconds that the UPS should wait between receiving the
shutdown command and actually shutting off. The other argument should
be set to the character 'n' only when the minutes value should be
skipped and not sent to the UPS. The default is type-dependent and is
given below. The braces and commas are mandatory. Note that there should
be no whitespace characters.
shutdown command and actually shutting off. The other argument should be set
to the character 'n' only when the minutes value should be skipped and not
sent to the UPS. The default is type-dependent and is given below. The braces
and commas are mandatory. Note that there should be no whitespace characters.
*voltage*={'coefficient1','coefficient2','coefficient3','coefficient4'}::
(Only for types KP625AP, Trust, Egys, BNT-other.)
A quad that is used convert the raw data to a human-readable voltage
reading. The default is type-dependent and is given below. Do note that
the braces and commas are mandatory, as well as the lack of whitespace
characters.
*numOfBytesFromUPS*='value'::
The number of bytes in a UPS frame: 16 is common, 11 for 'Trust'. The default
is type-dependent and is given below.
*frequency*={'coefficient1','coefficient2'}::
(Only for types KP625AP, Trust, Egys.)
A pair to convert the raw data to a human-readable frequency reading. The
default is type-dependent and is given below. Do note that the braces
and commas are mandatory as well, as the lack of whitespace characters.
*batteryPercentage*={'coefficient1','coefficient2','coefficient3','coefficient4','coefficient5'}::
(Only for KP625AP, Trust, Egys, BNT-other.)
A 5 tuple to convert the raw data to a human-readable battery percentage
reading. The default is type-dependent and is given below. Do note that
the braces and commas are mandatory, as the lack of white space
characters.
*loadPercentage*={'coefficient1','coefficient2','coefficient3','coefficient4'}::
(Only for types KP625AP, Trust, Egys, BNT-other.)
A quad to convert the raw data to human readable load percentage
reading. The default is type-dependent and is given below. Do note that
the braces and commas are mandatory, as the lack of white space
characters.
*methodOfFlowControl*='name'::
The method of serial communication flow control that is engaged by the UPS.
The default is type-dependent and is given below. Acceptable names are
'dtr0rts1', 'dtr1' or 'no_flow_control'.
*validationSequence*={{'index1','value1'},{'index2','value2'},{'index3','value3'}}::
(Only for types KP625AP, Trust, Egys, BNT-other.)
3 pairs to be used for validating the UPS by comparing bytes of the raw
data with constant values. The default is type-dependent and is given
below. The braces and commas are mandatory, as the lack of white space
(Only for types KP625AP, Trust, Egys.)
3 pairs to be used for validating the UPS by comparing bytes of the raw data
with constant values. The index selects the byte from the UPS (see
numOfBytesFromUPS) and the value is for matching to the byte. The default is
type-dependent and is given below. The braces and commas are mandatory, as
the lack of white space characters.
*frequency*={'A','B'}::
(Only for types KP625AP, Trust, Egys.)
A pair to convert the raw frequency data to a human-readable frequency
reading using the function 1/(A*x+B). If the raw value x IS the frequency,
then set A=1/(x^2) and B=0. The default is type-dependent and is given below.
Do note that the braces and commas are mandatory as well, as the lack of
whitespace characters.
*loadPercentage*={'BatteryA','BatteryB','LineA','LineB'}::
(Only for types KP625AP, Trust, Egys.)
A quad to convert the raw load data to human readable load percentage reading
using the function A*x+B. If the raw value x IS the Load Percent, then set
A=1 and B=0. The default is type-dependent and is given below. Do note that
the braces and commas are mandatory, as the lack of white space
characters.
*batteryPercentage*={'Battery1','Battery2','Battery3','Line4','Line5'}::
(Only for KP625AP, Trust, Egys.)
A 5 tuple to convert the raw battery and line data to a human-readable
battery and line percentage reading using the functions (Battery)
A*x+B*y+C and (Line) D*x+E. If the raw value x IS the Battery Percent, then
set A=1, B=0, C=0, D=1, E=0. The default is type-dependent and is given below.
Do note that the braces and commas are mandatory, as the lack of white space
characters.
*voltage*={'240A','240B','120A','120B'}::
(Only for types KP625AP, Trust, Egys.)
A quad that is used convert the raw voltage data to a human-readable voltage
reading using the function A*x+B. If the raw value x IS HALF the Voltage,
then set A=2, B=0. The default is type-dependent and is given below. Do note
that the braces and commas are mandatory, as well as the lack of whitespace
characters.
DEFAULT VALUES FOR THE EXTRA ARGUMENTS
@ -112,7 +113,9 @@ DEFAULT VALUES FOR THE EXTRA ARGUMENTS
serialnumber = Unknown
type = Trust
The rest of the default values for the extra arguments are type-dependent:
The rest of the default values for the extra arguments are type-dependent.
However, 'BNT-other' is a special type that can be used to override ALL
values for ALL models.
Trust
~~~~~
@ -136,10 +139,8 @@ KP625AP
batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82}
voltage = {1.9216,-0.0977,0.9545,0.0000}
Egys
~~~~
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{5,0x80},{7,0},{8,0}}
@ -149,49 +150,43 @@ Egys
batteryPercentage = {5.0000,0.3268,-825.00,2.2105,-355.37}
voltage = {1.9216,-0.0977,0.9545,0.0000}
IMP
~~~
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{5,0xFF},{7,0},{8,0}}
shutdownArguments = {{1,30},y}
KIN
~~~
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{11,0x4b},{8,0},{8,0}}
shutdownArguments = {{1,30},y}
BNT
~~~
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{11,0x42},{8,0},{8,0}}
shutdownArguments = {{1,30},y}
BNT-other
~~~~~~~~~
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{8,0},{8,0},{8,0}}
shutdownArguments = {{1,30},y}
loadPercentage = {1.4474,0.0,0.8594,0.0}
batteryPercentage = {5.0000,0.3268,-825.00,0.46511,0}
voltage = {1.9216,-0.0977,0.82857,0.0000}
frequency = {0.00027778,0.0000}
loadPercentage = {1.0000,0.0,1.0000,0.0}
batteryPercentage = {1.0000,0.0000,0.0000,1.0000,0.0000}
voltage = {2.0000,0.0000,2.0000,0.0000}
AUTHOR
------
Peter Bieringer <pb@bieringer.de>,
Alexey Sidorov <alexsid@altlinux.org>
Alexey Sidorov <alexsid@altlinux.org>,
Keven L. Ates <atescomp@gmail.com>
SEE ALSO
--------