/* eaton-mib.c - data to monitor Eaton Aphel PDUs (Basic and Complex)
*
* Copyright (C) 2008 - 2010
* Arnaud Quette <ArnaudQuette@Eaton.com>
* Copyright (C) 2008 - 2012
* Arnaud Quette <arnaud.quette@gmail.com>
* Arnaud Quette <ArnaudQuette@Eaton.com>
*
* Sponsored by Eaton <http://www.eaton.com>
* and MGE Office Protection Systems <http://www.mgeops.com>
* Supported by Eaton <http://www.eaton.com>
* and previously MGE Office Protection Systems <http://www.mgeops.com>
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
@ -348,7 +349,112 @@ static snmp_info_t eaton_marlin_mib[] = {
{ NULL, 0, 0, NULL, NULL, 0, NULL, NULL }
};
/* Pulizzi Monitored ePDU (Basic model, SNMP only)
* FIXME: to be completed
*
* Warning: there are 2 versions:
* - SA built MI.mib (old MIB)
* #define PULIZZI1_OID_MIB ".1.3.6.1.4.1.20677.3.1.1"
* #define PULIZZI1_OID_MODEL_NAME ".1.3.6.1.4.1.20677.3.1.1.1.2.0"
* - Eaton-Powerware-Monitored-ePDU_1.0.E.mib (new MIB) Vertical SW
*/
/* Pulizzi Switched ePDU */
#define EATON_PULIZZI_SW_MIB_VERSION "0.1"
#define PULIZZI_SW_OID_MIB ".1.3.6.1.4.1.20677.3.1.1"
#define PULIZZI_SW_OID_MODEL_NAME ".1.3.6.1.4.1.20677.2.1.1.0"
/* Some buggy FW also report sysOID = ".1.3.6.1.4.1.20677.1" */
#define EATON_PULIZZI_SWITCHED1_SYSOID ".1.3.6.1.4.1.20677.1"
#define EATON_PULIZZI_SWITCHED2_SYSOID ".1.3.6.1.4.1.20677.2"
static info_lkp_t pulizzi_sw_outlet_status_info[] = {
{ 1, "on" },
{ 2, "off" },
{ 0, NULL }
};
/* simply remap the above status to "yes" */
static info_lkp_t pulizzi_sw_outlet_switchability_info[] = {
{ 1, "yes" },
{ 2, "yes" },
{ 0, NULL }
};
/* Snmp2NUT lookup table for Eaton Pulizzi Switched ePDU MIB */
static snmp_info_t eaton_pulizzi_switched_mib[] = {
/* Device page */
{ "device.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON | Powerware",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "device.model", ST_FLAG_STRING, SU_INFOSIZE, PULIZZI_SW_OID_MODEL_NAME,
"Switched ePDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "device.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
/* UPS page */
{ "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "ups.model", ST_FLAG_STRING, SU_INFOSIZE, PULIZZI_SW_OID_MODEL_NAME,
"Switched ePDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
/* FIXME: to be moved to the device collection! */
{ "ups.date", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.1.4.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.time", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.1.3.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.macaddr", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.2.6.0",
"unknown", 0, NULL, NULL },
/* Outlet page */
/* Note: outlet.count is deduced, with guestimate_outlet_count() */
{ "outlet.id", 0, 1, NULL, "0", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "outlet.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, NULL, "All outlets",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "outlet.current", 0, 1.0, ".1.3.6.1.4.1.20677.2.8.6.4.2.0", NULL, 0, NULL, NULL },
{ "outlet.voltage", 0, 1.0, ".1.3.6.1.4.1.20677.2.8.6.4.1.0", NULL, 0, NULL, NULL },
{ "outlet.power", 0, 1.0, ".1.3.6.1.4.1.20677.2.8.6.4.3.0", NULL, 0, NULL, NULL },
/* outlet template definition
* Notes:
* - indexes start from 1, ie outlet.1 => <OID>.1
* - the first definition is used to determine the base index (ie 0 or 1)
* - outlet.count is estimated, based on the below OID iteration capabilities */
{ "outlet.%i.desc", ST_FLAG_RW | ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.1.%i.1.0", NULL, SU_FLAG_STATIC | SU_FLAG_OK | SU_OUTLET, NULL, NULL },
{ "outlet.%i.status", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.3.%i.0",
NULL, SU_FLAG_OK | SU_OUTLET, &pulizzi_sw_outlet_status_info[0], NULL },
{ "outlet.%i.id", 0, 1, NULL, "%i", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK | SU_OUTLET, NULL, NULL },
/* we use the same OID as outlet.n.status..., to expose switchability */
{ "outlet.%i.switchable", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.3.%i.0", "yes", SU_FLAG_STATIC | SU_FLAG_OK | SU_OUTLET, &pulizzi_sw_outlet_switchability_info[0], NULL },
/* FIXME: need to be added to the namespace! */
{ "outlet.%i.delay.reboot", ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.1.%i.5.0", NULL, SU_OUTLET, NULL, NULL },
/* "outlet1SequenceTime" is used for global sequence */
{ "outlet.%i.delay.start", ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.1.%i.4.0", NULL, SU_OUTLET, NULL, NULL },
/* instant commands. */
/* FIXME: not exposed as "outlet.load...", or otherwise specific processing applies (template instanciation) */
{ "load.on", 0, 1, ".1.3.6.1.4.1.20677.2.6.2.1.0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "load.off", 0, 2, ".1.3.6.1.4.1.20677.2.6.2.1.0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "load.on.delay", 0, 3, ".1.3.6.1.4.1.20677.2.6.2.1.0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "load.off.delay", 0, 4, ".1.3.6.1.4.1.20677.2.6.2.1.0", NULL, SU_TYPE_CMD, NULL, NULL },
/* WARNING: outlet 1 => index 2! */
{ "outlet.%i.load.on", 0, 1, ".1.3.6.1.4.1.20677.2.6.2.%i.0", NULL, SU_TYPE_CMD | SU_OUTLET | SU_CMD_OFFSET, NULL, NULL },
{ "outlet.%i.load.off", 0, 2, ".1.3.6.1.4.1.20677.2.6.2.%i.0", NULL, SU_TYPE_CMD | SU_OUTLET | SU_CMD_OFFSET, NULL, NULL },
{ "outlet.%i.load.cycle", 0, 3, ".1.3.6.1.4.1.20677.2.6.2.%i.0", NULL, SU_TYPE_CMD | SU_OUTLET | SU_CMD_OFFSET, NULL, NULL },
/* end of structure. */
{ NULL, 0, 0, NULL, NULL, 0, NULL, NULL }
};
mib2nut_info_t aphel_genesisII = { "aphel_genesisII", EATON_APHEL_MIB_VERSION, "", APHEL1_OID_MODEL_NAME, eaton_aphel_genesisII_mib, APHEL1_SYSOID };
mib2nut_info_t aphel_revelation = { "aphel_revelation", EATON_APHEL_MIB_VERSION, "", APHEL2_OID_MODEL_NAME, eaton_aphel_revelation_mib, APHEL2_SYSOID };
mib2nut_info_t eaton_marlin = { "eaton_epdu", EATON_MARLIN_MIB_VERSION, "", EATON_MARLIN_OID_MODEL_NAME, eaton_marlin_mib, EATON_MARLIN_SYSOID };
/*mib2nut_info_t pulizzi_monitored = { "pulizzi_monitored", EATON_PULIZZI_MIB_VERSION, "", PULIZZI1_OID_MODEL_NAME, eaton_pulizzi_monitored_mib, PULIZZI1_OID_MIB };*/
mib2nut_info_t pulizzi_switched1 = { "pulizzi_switched1", EATON_PULIZZI_SW_MIB_VERSION, "", EATON_PULIZZI_SWITCHED1_SYSOID, eaton_pulizzi_switched_mib, EATON_PULIZZI_SWITCHED1_SYSOID };
mib2nut_info_t pulizzi_switched2 = { "pulizzi_switched2", EATON_PULIZZI_SW_MIB_VERSION, "", EATON_PULIZZI_SWITCHED1_SYSOID, eaton_pulizzi_switched_mib, EATON_PULIZZI_SWITCHED2_SYSOID };