UPSCODE2(8)
|
||||
===========
|
||||
|
||||
NAME
|
||||
----
|
||||
upscode2 - Driver for UPScode II compatible UPS equipment
|
||||
|
||||
NOTE
|
||||
----
|
||||
This man page only documents the hardware-specific features of the
|
||||
upscode2 driver. For information about the core driver, see
|
||||
linkman:nutupsdrv[8].
|
||||
|
||||
SUPPORTED HARDWARE
|
||||
------------------
|
||||
This driver supports UPS equipment which can be controlled via the UPScode II
|
||||
protocol. This is mainly Fiskars, Powerware equipment, but also
|
||||
some (probably OEM'ed) products from Compaq.
|
||||
|
||||
EXTRA ARGUMENTS
|
||||
---------------
|
||||
This driver supports the following optional settings in the
|
||||
linkman:ups.conf[5]:
|
||||
|
||||
*manufacturer*='value'::
|
||||
Autodetection of this parameter is not possible yet (and it probably
|
||||
never will be). Therefore, this user-defined string accepts any name. The
|
||||
default is 'unknown'.
|
||||
|
||||
*input_timeout*='value'::
|
||||
The timeout waiting for a response from the UPS. Some UPS models have
|
||||
shown to be rather slow, resulting in frequent messages about empty
|
||||
responses from the UPS. If you see this, try increasing this value.
|
||||
|
||||
*output_pace*='value'::
|
||||
Delay between characters sent to the UPS. This was added for completeness
|
||||
with the above parameter. It has not shown to be needed yet.
|
||||
|
||||
*baudrate*='value'::
|
||||
The default baudrate is 1200, which is the standard for the UPScode II
|
||||
protocol.
|
||||
|
||||
*full_update_timer*='value'::
|
||||
Number of seconds between collection of normative values.
|
||||
|
||||
*use_crlf*::
|
||||
Flag to set if commands towards to UPS need to be terminated with CR-LF,
|
||||
and not just CR.
|
||||
|
||||
*use_pre_lf*::
|
||||
Flag to set if commands towards to UPS need to be introduced with an LF.
|
||||
A Compaq T1500h is known to need this.
|
||||
|
||||
COMMANDS
|
||||
--------
|
||||
|
||||
The driver supports the following commands for those UPSen that support them.
|
||||
The available commands are autodetected during initialization,
|
||||
so you should check availability with 'upscmd -l'.
|
||||
|
||||
* test.panel.start - Start UPS self test
|
||||
|
||||
* test.battery.start - Start battery self test
|
||||
|
||||
* beeper.enable - Enable UPS beeper
|
||||
|
||||
* beeper.disable - Disable UPS beeper
|
||||
|
||||
* shutdown.return - Shut down in 1 second and wait for power to return
|
||||
|
||||
* shutdown.stayoff - Shut down in 1 seconds
|
||||
|
||||
* shutdown.reboot - Shut down in 1 seconds and reboot after 1 minute
|
||||
|
||||
* shutdown.reboot.graceful - Shut down in 20 seconds and reboot after 1 minute
|
||||
|
||||
NOTES
|
||||
-----
|
||||
|
||||
The Powerware UPS models that this driver has been tested against until now
|
||||
have not returned a value for 'battery.charge'. Therefore, the driver will
|
||||
guestimate a value based on the nominal battery min/max and the current
|
||||
battery voltage.
|
||||
|
||||
AUTHOR
|
||||
------
|
||||
Håvard Lygre <hklygre@online.no>,
|
||||
Niels Baggesen <niels@baggesen.net>
|
||||
|
||||
SEE ALSO
|
||||
--------
|
||||
|
||||
The core driver:
|
||||
~~~~~~~~~~~~~~~~
|
||||
linkman:nutupsdrv[8]
|
||||
|
||||
Internet resources:
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|
||||