POWERCOM(8)
|
||||
===========
|
||||
|
||||
NAME
|
||||
----
|
||||
|
||||
powercom - UPS driver for Powercom/Trust/Advice UPS equipment
|
||||
|
||||
NOTE
|
||||
----
|
||||
This man page only documents the hardware-specific features of the
|
||||
powercom driver. For information about the core driver, see
|
||||
linkman:nutupsdrv[8].
|
||||
|
||||
SUPPORTED HARDWARE
|
||||
------------------
|
||||
This driver supports many similar kinds of UPS hardware. The most common
|
||||
ones are the Trust 425/625, Powercom, and Advice Partner/King PR750.
|
||||
Others using the same protocol may also work.
|
||||
|
||||
EXTRA ARGUMENTS
|
||||
---------------
|
||||
This driver supports the following optional settings in the
|
||||
linkman:ups.conf[5] file:
|
||||
|
||||
*linevoltage*='value'::
|
||||
An integer specifying the mains voltage. It can't be auto detected.
|
||||
Acceptable values are in the range of 110--120 or 220--240. The default
|
||||
is '230'.
|
||||
|
||||
*manufacturer*='name'::
|
||||
Specify the manufacturer name, which also can't be auto detected. This is
|
||||
a user defined string, so any name is acceptable. The default is
|
||||
'PowerCom'.
|
||||
|
||||
*modelname*='name'::
|
||||
Specify the model name, which also can't be auto detected. This is a
|
||||
user defined string, so any name is acceptable. The default is
|
||||
'Unknown'.
|
||||
|
||||
*serialnumber*='value'::
|
||||
Like modelname above, but for the serial number. The default is
|
||||
'Unknown'.
|
||||
|
||||
*type*='name'::
|
||||
The exact type of the communication protocol within the powercom family,
|
||||
that will be used to communicate with the UPS. The type is named after
|
||||
the first modelname that was coded with that protocol. The acceptable
|
||||
names are 'KP625AP', 'Trust', 'Egys', 'KIN', 'BNT', 'IMP' and 'BNT-other'. The
|
||||
default is 'Trust'.
|
||||
+
|
||||
'BNT-other' is a special type for BNT 100-120V models.
|
||||
For this type you can (I think must!) specify voltage, batteryPercentage,
|
||||
loadPercentage and validationSequence.
|
||||
|
||||
*numOfBytesFromUPS*='value'::
|
||||
The number of bytes in a UPS frame. The default is type-dependent and
|
||||
is given below.
|
||||
|
||||
*methodOfFlowControl*='name'::
|
||||
The method of serial communication flow control that is engaged by the
|
||||
UPS. The default is type-dependent and is given below. Acceptable names
|
||||
are 'dtr0rts1', 'dtr1' or 'no_flow_control'.
|
||||
|
||||
*shutdownArguments*={{'minutes','seconds'},'whether_minutes_should_be_used'}::
|
||||
The minutes and seconds that the UPS should wait between receiving the
|
||||
shutdown command and actually shutting off. The other argument should
|
||||
be set to the character 'n' only when the minutes value should be
|
||||
skipped and not sent to the UPS. The default is type-dependent and is
|
||||
given below. The braces and commas are mandatory. Note that there should
|
||||
be no whitespace characters.
|
||||
|
||||
*voltage*={'coefficient1','coefficient2','coefficient3','coefficient4'}::
|
||||
(Only for types KP625AP, Trust, Egys, BNT-other.)
|
||||
A quad that is used convert the raw data to a human-readable voltage
|
||||
reading. The default is type-dependent and is given below. Do note that
|
||||
the braces and commas are mandatory, as well as the lack of whitespace
|
||||
characters.
|
||||
|
||||
*frequency*={'coefficient1','coefficient2'}::
|
||||
(Only for types KP625AP, Trust, Egys.)
|
||||
A pair to convert the raw data to a human-readable frequency reading. The
|
||||
default is type-dependent and is given below. Do note that the braces
|
||||
and commas are mandatory as well, as the lack of whitespace characters.
|
||||
|
||||
*batteryPercentage*={'coefficient1','coefficient2','coefficient3','coefficient4','coefficient5'}::
|
||||
(Only for KP625AP, Trust, Egys, BNT-other.)
|
||||
A 5 tuple to convert the raw data to a human-readable battery percentage
|
||||
reading. The default is type-dependent and is given below. Do note that
|
||||
the braces and commas are mandatory, as the lack of white space
|
||||
characters.
|
||||
|
||||
*loadPercentage*={'coefficient1','coefficient2','coefficient3','coefficient4'}::
|
||||
(Only for types KP625AP, Trust, Egys, BNT-other.)
|
||||
A quad to convert the raw data to human readable load percentage
|
||||
reading. The default is type-dependent and is given below. Do note that
|
||||
the braces and commas are mandatory, as the lack of white space
|
||||
characters.
|
||||
|
||||
*validationSequence*={{'index1','value1'},{'index2','value2'},{'index3','value3'}}::
|
||||
(Only for types KP625AP, Trust, Egys, BNT-other.)
|
||||
3 pairs to be used for validating the UPS by comparing bytes of the raw
|
||||
data with constant values. The default is type-dependent and is given
|
||||
below. The braces and commas are mandatory, as the lack of white space
|
||||
characters.
|
||||
|
||||
DEFAULT VALUES FOR THE EXTRA ARGUMENTS
|
||||
--------------------------------------
|
||||
linevoltage = 230
|
||||
manufacturer = PowerCom
|
||||
modelname = Unknown
|
||||
serialnumber = Unknown
|
||||
type = Trust
|
||||
|
||||
The rest of the default values for the extra arguments are type-dependent:
|
||||
|
||||
Trust
|
||||
~~~~~
|
||||
numOfBytesFromUPS = 11
|
||||
methodOfFlowControl = dtr0rts1
|
||||
validationSequence = {{5,0},{7,0},{8,0}}
|
||||
shutdownArguments = {{0,10},n}
|
||||
frequency = {0.00020997,0.00020928}
|
||||
loadPercentage = {6.1343,-0.3808,4.3110,0.1811}
|
||||
batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82}
|
||||
voltage = {1.9216,-0.0977,0.9545,0.0000}
|
||||
|
||||
KP625AP
|
||||
~~~~~~~
|
||||
numOfBytesFromUPS = 16
|
||||
methodOfFlowControl = dtr0rts1
|
||||
validationSequence = {{5,0x80},{7,0},{8,0}}
|
||||
shutdownArguments = {{0,10},n}
|
||||
frequency = {0.00020997,0.00020928}
|
||||
loadPercentage = {6.1343,-0.3808,4.3110,0.1811}
|
||||
batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82}
|
||||
voltage = {1.9216,-0.0977,0.9545,0.0000}
|
||||
|
||||
|
||||
Egys
|
||||
~~~~
|
||||
|
||||
numOfBytesFromUPS = 16
|
||||
methodOfFlowControl = no_flow_control
|
||||
validationSequence = {{5,0x80},{7,0},{8,0}}
|
||||
shutdownArguments = {{0,10},n}
|
||||
frequency = {0.00020997,0.00020928}
|
||||
loadPercentage = {6.1343,-0.3808,1.3333,0.6667}
|
||||
batteryPercentage = {5.0000,0.3268,-825.00,2.2105,-355.37}
|
||||
voltage = {1.9216,-0.0977,0.9545,0.0000}
|
||||
|
||||
|
||||
IMP
|
||||
~~~
|
||||
|
||||
numOfBytesFromUPS = 16
|
||||
methodOfFlowControl = no_flow_control
|
||||
validationSequence = {{5,0xFF},{7,0},{8,0}}
|
||||
shutdownArguments = {{1,30},y}
|
||||
|
||||
|
||||
KIN
|
||||
~~~
|
||||
|
||||
numOfBytesFromUPS = 16
|
||||
methodOfFlowControl = no_flow_control
|
||||
validationSequence = {{11,0x4b},{8,0},{8,0}}
|
||||
shutdownArguments = {{1,30},y}
|
||||
|
||||
|
||||
BNT
|
||||
~~~
|
||||
|
||||
numOfBytesFromUPS = 16
|
||||
methodOfFlowControl = no_flow_control
|
||||
validationSequence = {{11,0x42},{8,0},{8,0}}
|
||||
shutdownArguments = {{1,30},y}
|
||||
|
||||
|
||||
BNT-other
|
||||
~~~~~~~~~
|
||||
|
||||
numOfBytesFromUPS = 16
|
||||
methodOfFlowControl = no_flow_control
|
||||
validationSequence = {{8,0},{8,0},{8,0}}
|
||||
shutdownArguments = {{1,30},y}
|
||||
loadPercentage = {1.4474,0.0,0.8594,0.0}
|
||||
batteryPercentage = {5.0000,0.3268,-825.00,0.46511,0}
|
||||
voltage = {1.9216,-0.0977,0.82857,0.0000}
|
||||
|
||||
AUTHOR
|
||||
------
|
||||
Peter Bieringer <pb@bieringer.de>,
|
||||
Alexey Sidorov <alexsid@altlinux.org>
|
||||
|
||||
SEE ALSO
|
||||
--------
|
||||
|
||||
The core driver:
|
||||
~~~~~~~~~~~~~~~~
|
||||
linkman:nutupsdrv[8]
|
||||
|
||||
Internet resources:
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|
||||