Imported Upstream version 2.6.2
This commit is contained in:
parent
a367d9bc54
commit
45043b58d0
246 changed files with 18228 additions and 1415 deletions
|
|
@ -11,30 +11,63 @@ SYNOPSIS
|
|||
|
||||
*apcsmart* -h
|
||||
|
||||
*apcsmart* -a 'UPS_NAME' ['OPTIONS']
|
||||
*apcsmart* -a \'UPS_NAME' [-x option=value ...]
|
||||
|
||||
NOTE: This man page only documents the hardware-specific features of the
|
||||
apcsmart driver. For information about the core driver, see
|
||||
apcsmart driver. For information about the core driver, see
|
||||
linkman:nutupsdrv[8].
|
||||
|
||||
|
||||
SUPPORTED HARDWARE
|
||||
------------------
|
||||
|
||||
apcsmart should recognize all recent APC models that use a serial
|
||||
protocol at 2400 bps. This is primarily the Smart-UPS, Matrix-UPS and
|
||||
Back-UPS Pro lines.
|
||||
The apcsmart driver should recognize (or at the very least work with) majority
|
||||
of Smart-UPS models - which includes Smart-UPS, Matrix-UPS and Back-UPS lineups,
|
||||
among few other ones.
|
||||
|
||||
The driver attempts to support every bell and whistle of the APC
|
||||
reporting interface, whether or not this is strictly sensible.
|
||||
Currently we can roughly divide APC hardware into 3 groups (note that the
|
||||
division isn\'t strict by any means, and the borders between those are pretty fuzzy):
|
||||
|
||||
Some older hardware may only report a handful of variables. This is
|
||||
usually not a bug--they just don't support anything else.
|
||||
[very] "old" models::
|
||||
These models usually have old APC logo, white color and _no_ programmable
|
||||
eeprom; You won\'t find them listed anywhere on APC's site either. The support
|
||||
for those will be usually based on driver\'s compatibility tables, or if the
|
||||
model (firmware) is not listed in those - the driver will try to follow the very
|
||||
basic subset of features, while still trying to remain useful. Despite
|
||||
"smart" tagname, they often tend to behave in pretty dumb way (see the
|
||||
section below about shutdown behaviour).
|
||||
+
|
||||
--
|
||||
.Example models:
|
||||
* Smart-UPS 2000I
|
||||
* Smart-UPS 900I
|
||||
--
|
||||
|
||||
"new" models::
|
||||
These models usually come from late 1990s / pre-2009 times. They are often
|
||||
referred as "3rd. gen". For the most part, they have programmable eeprom,
|
||||
report supported commands and capabilites, and should work just fine with the
|
||||
apcsmart driver.
|
||||
|
||||
"microlink" models::
|
||||
WARNING: these are not _natively_ supported by apcsmart (or apcupsd for that
|
||||
matter, if you\'re wondering). Around 2007 APC (now APC Schneider) decided to
|
||||
go back to its proprietry roots and all the new models (SMT, SMX, SURTD) use
|
||||
completely different protocol and cables. If you purchased a new APC ups,
|
||||
that uses cable with rj45 on the one end, and db-9 on the other - then you
|
||||
have such model. Your only option to support it through *NUT* is to
|
||||
purchase "legacy communications card" - part #AP9620 (google \'AP9620' for
|
||||
more details). Or if that\'s not an option, rely on official software.
|
||||
|
||||
Another thing to remember is that Smart protocol is not USB protocol. If you
|
||||
have ups with both USB and serial ports, then depending on how you connect it,
|
||||
you will need either apcsmart or usbhid-ups driver.
|
||||
|
||||
CABLING
|
||||
-------
|
||||
|
||||
This driver expects to see a 940-0024C cable or a clone by default. You
|
||||
can switch to the 940-0095B dual-mode cable support with the `cable=`
|
||||
This driver expects to see a 940-0024C cable or a clone by default. You
|
||||
can switch to the 940-0095B dual-mode cable support with the \'cable='
|
||||
definition described below.
|
||||
|
||||
If your 940-0024C cable is broken or missing, use this diagram to build
|
||||
|
|
@ -42,42 +75,246 @@ a clone:
|
|||
|
||||
http://www.networkupstools.org/cables/940-0024C.jpg
|
||||
|
||||
EXTRA ARGUMENTS
|
||||
---------------
|
||||
You can specify alternate cable in linkman:ups.conf[5]:
|
||||
|
||||
This driver supports the following optional settings in the
|
||||
linkman:ups.conf[5]:
|
||||
*cable*=940-0095B
|
||||
|
||||
*cable=940-0095B*::
|
||||
Configure the serial port for the APC 940-0095B dual-mode cable.
|
||||
Alternatively, you can also provide it on the command line using:
|
||||
|
||||
*sdtype=*'num'::
|
||||
Use shutdown type 'num', according to this table:
|
||||
-x *cable*=940-0095B
|
||||
|
||||
0;; soft shutdown or powerdown, depending on battery status
|
||||
EXPLANATION OF SHUTDOWN METHODS SUPPORTED BY APC UPSES
|
||||
------------------------------------------------------
|
||||
|
||||
1;; soft shutdown followed by powerdown
|
||||
APC hardware supports a lot of shutdown methods, that themselves can differ in
|
||||
behaviour quite a bit, depending on the model.
|
||||
|
||||
2;; instant power off
|
||||
*S* (soft hibernate)::
|
||||
This is most basic command present in probably all APC models. It will
|
||||
hibernate the UPS, and subsequently wake it up when the mains supply
|
||||
returns. *The command doesn\'t work if UPS is running on mains.*
|
||||
|
||||
3;; power off with grace period
|
||||
"old" models:::
|
||||
The behaviour here is unfortunately pretty primitive - when the power
|
||||
returns, the ups just wakes up. No grace periods, no min. battery
|
||||
charge condition, etc. This is probably not what you want.
|
||||
|
||||
4;; "force OB" hack method for CS 350
|
||||
"new" models:::
|
||||
The behaviour here is as expected - the power is cut off after the
|
||||
eeprom defined grace period. The ups will wake up when the power
|
||||
returns, after the eeprom defined delay AND if the eeprom defined min.
|
||||
battery charge level is met. The delay is counted from the power\'s
|
||||
return.
|
||||
|
||||
Modes 0 and 1 will power up the load when power returns. Modes 2 and 3
|
||||
will keep the load turned off when the power returns.
|
||||
*CS* (aka "force OB hack")::
|
||||
This is a trick to make UPS power down even if it\'s running on mains.
|
||||
Immediately before issuing *S*, "simulate power failure" is issued. The
|
||||
remaining behaviour is as in *S* case.
|
||||
+
|
||||
The name came from APC CS models, where such trick was used to power down
|
||||
UPSes in consistent fashion using only *S*. It\'s better to use *@nnn*
|
||||
command if your UPS supports it (and is not too old, see below).
|
||||
|
||||
Mode 4 exploits an oddity in the CS 350 models since they only seem to
|
||||
support the S command, but then only when running on battery. As a
|
||||
result, the driver will force the UPS to go on battery if necessary
|
||||
before sending the shutdown command. This ensures that the load gets
|
||||
reset.
|
||||
*@nnn* (hard hibernate)::
|
||||
This is basic command used to hibernate UPS regardless if it\'s
|
||||
running on batteries or on mains. The option takes 3 digits argument which
|
||||
can be used to specify additional wakeup delay (in 6 minute units).
|
||||
+
|
||||
--
|
||||
"old" models:::
|
||||
The behaviour is - unfortunately - similary primitive to *S*. The ups
|
||||
unconditionally wakes up after $$nnn*6$$ minutes - *it doesn\'t care if the
|
||||
power returned !* If nnn = 000, then UPS will do precisely nothing. On
|
||||
those models you\'re better specifying nnn > 0, if you can estimate
|
||||
the kind of power problems that might be happening in your environment.
|
||||
Another thing to consider with "old" models - you might lose the
|
||||
connection with the ups, until it wakes up (with *S*, the serial
|
||||
connection is kept alive).
|
||||
|
||||
"new" models:::
|
||||
All the usual variables defined in eeprom are respected (see *S*).
|
||||
Additionally, if nnn > 0, the $$nnn*6$$ minutes are added to eeprom
|
||||
defined delay. UPS will not power up if it\'s running on batteries,
|
||||
contrary to what "old" models used to do - the combined delay is counted
|
||||
from the moment of power return.
|
||||
--
|
||||
+
|
||||
Supposedly there exist models that take 2 digits instead of 3. Just in case,
|
||||
NUT also supports such variation. You have to provide exactly 2 digits to
|
||||
trigger it (*awd* option, or argument to one of the supported instant commands).
|
||||
|
||||
*K* (delayed poweroff)::
|
||||
This is permanent poweroff - the ups will not wake up automatically. On
|
||||
newer units, it will respect applicable eeprom variables.
|
||||
|
||||
*Z* (instant poweroff)::
|
||||
This is also permanent poweroff - the ups will not wake up automatically. The
|
||||
poweroff is executed immediately.
|
||||
|
||||
SHUTDOWN CONTROL BY NUT
|
||||
-----------------------
|
||||
|
||||
There\'re 3 options used to control shutdown behaviour.
|
||||
|
||||
*sdtype*=[0-5]::
|
||||
This option takes a single digit (0-5) as an argument. See below for
|
||||
details.
|
||||
|
||||
*advorder*=no|[0-4]+::
|
||||
This option takes string of digits as an argument. Methods listed are tried
|
||||
in turn until one of them succeedes. Note that the meaning of digits is
|
||||
different from *sdtype*. See below for details.
|
||||
|
||||
*awd*=[0-9]{1,3}::
|
||||
This option lets you specify additional wakeup delay used by *@*. If you
|
||||
provide exactly 2 digits, the driver will try 2 digits variation (see
|
||||
previous section for more info). Otherwise standard 3 digits variation is
|
||||
used. *Note: the time unit is 6 minutes !*
|
||||
|
||||
Keep in mind that *sdtype* and *advorder* are mutually exclusive. If *advorder*
|
||||
is provided, *sdtype* is ignored. If *advorder* is set to \'no', *sdtype* is
|
||||
used instead.
|
||||
|
||||
If nothing is provided, *NUT* will assume *sdtype*=0 - which is generally fine
|
||||
for anything not too ancient or not too quirky.
|
||||
|
||||
SDTYPE
|
||||
~~~~~~
|
||||
|
||||
The values permitted are from 0 to 5. Only one can be specified. Anything else
|
||||
will cause apcsmart to exit.
|
||||
|
||||
0::
|
||||
issue soft hibernate (*S*) if the ups is running on batteries, otherwise issue
|
||||
hard hibernate (*@*)
|
||||
1::
|
||||
issue soft hibernate (*S*) (if on batteries), and if it fails (or on mains) -
|
||||
try hard hibernate (*@*)
|
||||
2::
|
||||
issue instant poweroff (*Z*)
|
||||
3::
|
||||
issue delayed poweroff (*K*)
|
||||
4::
|
||||
issue "force OB hack" (*CS*)
|
||||
5::
|
||||
issue hard hibernate (*@*)
|
||||
|
||||
NOTE: Hard hibernate\'s additional wakeup delay can be provided by *awd*.
|
||||
|
||||
ADVORDER
|
||||
~~~~~~~~
|
||||
|
||||
The argument is either a word \'no', or a string of 1 - 5 digits in [0 - 4]
|
||||
range. Each digit maps to the one of shutdown methods supported by APC upses.
|
||||
Methods listed in this way are tried in order, until one of them succedes.
|
||||
|
||||
If *advorder* is undefined or set to \'no', *sdtype* is used instead.
|
||||
|
||||
The mapping is as follows:
|
||||
|
||||
[horizontal]
|
||||
0:: soft hibernate (*S*)
|
||||
1:: hard hibernate (*@*)
|
||||
2:: delayed poweroff (*K*)
|
||||
3:: instant poweroff (*Z*)
|
||||
4:: "force OB hack" (*CS*)
|
||||
|
||||
NOTE: Hard hibernate\'s additional wakeup delay can be provided by *awd*.
|
||||
|
||||
IGNORING LB STATE
|
||||
-----------------
|
||||
|
||||
APC units - even if they report LB mode - will not go into shutdown
|
||||
automatically. This gives us even more control with reference to "when to
|
||||
actually shutdown psu". Since version 2.6.2, NUT supports *ignorelb* option in
|
||||
driver\'s section of linkman:ups.conf[5]. When such option is in effect,
|
||||
the core driver will ignore LB state as reported by specific driver and
|
||||
start shutdown basing the decision _only_ on two conditions:
|
||||
|
||||
battery.charge < battery.charge.low
|
||||
|
||||
*OR*
|
||||
|
||||
battery.runtime < battery.runtime.low
|
||||
|
||||
Of course - if any of the variables are not available, the appropriate condition
|
||||
is not checked. If you want to explicitly disable one of the conditions, simply
|
||||
override the right hand variable causing the condition to always evaluate to
|
||||
false (you can even provide negative numbers).
|
||||
|
||||
APC upses don\'t have battery.charge.low - you will have to define it if you want
|
||||
to use such condition (prefix the variable with override. or default.).
|
||||
|
||||
"New" units have battery.runtime.low, but depending on battery quality, firmware
|
||||
version, calibration and ups load - this variable can be underestimated quite a bit -
|
||||
especially right after going into OB state. This in turn can cause LB to be
|
||||
asserted, which under normal conditions will cause *NUT* to initiate the
|
||||
shutdown. You might want to disable this condition entirely, when relying on
|
||||
*ignorelb* option (this was actually the main motivation behind introduction of
|
||||
such feature).
|
||||
|
||||
Simple example:
|
||||
|
||||
[source,conf]
|
||||
----
|
||||
[apc]
|
||||
ignorelb
|
||||
override.battery.charge.low = 15
|
||||
override.battery.runtime.low = -1
|
||||
----
|
||||
|
||||
This would cause apcsmart to go into shutdown _only_ if detected battery charge
|
||||
< 15%. Runtime condition is always false in this example.
|
||||
|
||||
You could ask - why bother ? Well, the reason is already hinted above. APC units
|
||||
can be very picky about the batteries, and their firmware can underestimate the
|
||||
remaining runtime (especially right after going into OB state). *ignorelb*
|
||||
option and *$$override.*$$* let you remain in control of the ups, not ups in control
|
||||
of you.
|
||||
|
||||
Furthermore, this allows to specify conditions similary to how it's done in
|
||||
apcupsd daemon, so it should be welcome by people used to that software.
|
||||
|
||||
|
||||
SUPPORTED INSTANT COMMANDS
|
||||
--------------------------
|
||||
|
||||
The apcsmart driver exposes following instant commands:
|
||||
|
||||
shutdown.return::
|
||||
executes soft hibernate
|
||||
shutdown.return cs::
|
||||
executes "force OB hack"
|
||||
shutdown.return at:<nbr>::
|
||||
executes "hard hibernate" with $$<nbr>*6$$ minutes additional wakeup delay (<nbr> format
|
||||
is the same as of *awd* option)
|
||||
shutdown.stayoff::
|
||||
executes "delayed poweroff"
|
||||
load.off::
|
||||
executes "instant poweroff"
|
||||
|
||||
All the above commands must be issued 2nd time to have any effect (no less than 3
|
||||
seconds, and no more than 15 seconds after the initial call). Those commands are
|
||||
mostly useful for manual testing, when your machine is not powered by the ups
|
||||
you\'re testing.
|
||||
|
||||
Other supported commands:
|
||||
|
||||
- load.on
|
||||
- test.panel.start
|
||||
- test.failure.start
|
||||
- test.battery.start
|
||||
- test.battery.stop
|
||||
- bypass.start
|
||||
- bypass.stop
|
||||
- calibrate.start
|
||||
- calibrate.stop
|
||||
|
||||
BUGS
|
||||
----
|
||||
|
||||
Some older APC UPS models return bogus data in the status register during
|
||||
a front panel test. This is usually detected and discarded, but some
|
||||
a front panel test. This is usually detected and discarded, but some
|
||||
other unexpected values have occasionally slipped through.
|
||||
|
||||
APC UPS models with both USB and serial ports require a power cycle when
|
||||
|
|
@ -85,17 +322,20 @@ switching from USB communication to serial, and perhaps vice versa.
|
|||
|
||||
AUTHOR
|
||||
------
|
||||
|
||||
Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk> (drawing
|
||||
heavily on the original apcsmart driver by Russell Kroll). This driver
|
||||
was called newapc for a time and was renamed in the 1.5 series.
|
||||
heavily on the original apcsmart driver by Russell Kroll). This driver
|
||||
was called newapc for a time and was renamed in the 1.5 series. In 2.6.2
|
||||
it was renamed to apcsmart-old, being superseded by updated version with
|
||||
new features, which is maintained by Michal Soltys <soltys@ziu.info>
|
||||
|
||||
SEE ALSO
|
||||
--------
|
||||
|
||||
The core driver:
|
||||
~~~~~~~~~~~~~~~~
|
||||
linkman:nutupsdrv[8]
|
||||
linkman:nutupsdrv[8], linkman:ups.conf[5]
|
||||
|
||||
Internet resources:
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|
||||
|
||||
// vim: tw=80 ai si ts=8 sts=4 sw=4 et :
|
||||
|
|
|
|||
Loading…