Release notes for NUT 2.6.0 - what's new since 2.4.3:
- the main focus of this release is the complete documentation revamping,
using AsciiDoc. This includes a new website, user manual, developer guide,
packager guide and manual pages, available in various formats (single and
multiple pages HTML, and PDF at the moment).
Be sure to check the --with-doc configure option help, and
docs/configure.txt for more information.
- Add Augeas support, to provide easy NUT configuration management, through
tools and development APIs. For more information, refer to the developer
guide, or scripts/augeas/README in the source directory.
- support for new devices: APC 5G; Eaton PowerWare 5119 RM (smart mode using
upscode2 driver), Eaton Best Ferrups (using older ConnectUPS card),
Eaton 9395 (serial interface), Eaton ConnectUPS X / BD / E Slot;
HP T1000 INTL, HP T1500 INTL, HP T750 G2, HP R1500 G2 INTL; iDowell iBox UPS;
Tripp Lite SmartOnline SU1000XLA, Tripp Lite Smart1000LCD, and some
more USB/HID devices IDs; CyberPower CP1500AVRLCD and CP1350AVRLCD;
PowerWalker Line-Interactive VI 1400 ; Rocketfish RF-1000VA / RF-1025VA.
- usbhid-ups has better support for shutting down APC SmartUPS RM series,
and finally fix the "buffer size" issue, which was breaking some
devices data retrieval, or truncating some data on others.
- snmp-ups now support SNMP v3 and its security parameters. IETF MIB support
has also been extended.
- fix dummy-ups simulation driver status handling bug, and add the
capability to remove exposed variables on the fly.
- the belkin driver now support control commands and status reporting
for beeper and battery test.
- the powerpanel driver supports more older CyberPower units.
- mge-utalk, upscode2, blazer and liebert-esp2 have also received some
care, and been improved.
- NUT-Monitor and the PyNUT client module have been updated to 1.3,
adding more features like automatic connection to the first local device
and i18n support.
- improve configure time dependencies checking and processing.
- improve older Unix systems support (HP-UX, Aix, ...) for missing functions.
- refresh and improve USB helper files (udev and UPower).
- more generation automation: the ChangeLog file is now generated
automatically at distribution time, along with the files needed for
the website hardware compatibility list.
- SSL support has also received some improvements.
- tcp-wrapper now allows hostnames in /etc/hosts.allow too (not only IPv4
and/or IPv6 addresses).
- many bugfixes, cleanup and improvements.
2010-03-25 23:20:59 +00:00
---------------------------------------------------------------------------
Release notes for NUT 2.4.3 - what's new since 2.4.2:
- this is a bugfix release that only solves the regression on IPv6 activation.
---------------------------------------------------------------------------
Release notes for NUT 2.4.2 - what's new since 2.4.1:
- the general USB support has been vastly improved, including many bug
fixes, better OS support, new features and devices.
- NUT now talks to Solar Controller Devices with the new ivtscd driver.
- the snmp-ups driver supports more PDU, with a smaller disk footprint.
- apcsmart supports more older SmartUPS and Matrix units.
- the bestfortress driver is resurrected.
- the virtual driver has been renamed to 'clone'.
- the netxml-ups driver has received some care.
- various debugging and development improvements have been done, around
driver output; dummy-ups with more interaction and scripting and the
device-recorder.sh script.
- the build system has received many bugfixes and improvements.
- the UPower (previously known as DeviceKit-power) rules file is now
generated by NUT.
- support for new devices: Apollo 1000A and 1000F; various Baytech RPC; old
Best Power Fortress; Cyber Power Systems PR3000E, CP 1500C and OR2200LCDRM2U;
all the new Dell UPS range (serial, USB and network); Eaton E Series NV and
DX UPS, and Powerware 9130; older HP T500 and T750, newer T750 INTL (USB) and
R1500 G2 (serial); Inform Informer Compact 1000VA; many serial and USB
devices from Ippon, like Back Comfo Pro, Smart Power Pro and Smart Winner;
IVT SCD series; Liebert GXT2-3000RT230 and PowerSure PSA; Mustek PowerMust
424 / 636 / 848 USB; all new PowerCOM USB devices with HID PDC interface;
Tripp-Lite INTERNETOFFICE700, SMART700USB and ECO550UPS; UPSonic DS-800
(USB).
---------------------------------------------------------------------------
Release notes for NUT 2.4.1 - what's new since 2.4.0:
- the microdowell driver has appeared to support various MicroDowell Enterprise
units (see the "new devices" list below).
- support for new devices: MicroDowell Enterprise B8, B10, N8, N11, N15, N20,
N22, N30, N40, N50, N60 and HiBox ST.
- NUT-Monitor now better handles the ups.status field, and has switched to
version 1.1.
- the situation of the build toolchain has been fixed, with regard to the
"make clean" target and the wrongly removed generated USB files. This brokes
further configure call.
---------------------------------------------------------------------------
Release notes for NUT 2.4.0 - what's new since 2.2.2:
- preliminary support for Power Distribution Units (PDUs): NUT now support
PDUs, either natively (ie using NUT snmp-ups driver), or through a binding to
the Powerman daemon. The list of supported PDUs is already quite long,
including: Eaton ePDUs (Managed and Monitored), some Aphel models, some
Raritan PDUs, and the whole list of Powerman supported devices:
http://powerman.sourceforge.net/supported.html
- support for new devices: the various PDUs cited above, Chloride Desk Power
650, Cyber Power Systems Value 400E/600E/800E (USB models), Delta GES602N,
Digitus DN-170020, the whole Eaton ranges (mostly composed of MGE Office
Protection Systems and Powerware units) including BladeUPS, Forza Power
Technologies SL-1001, HP PowerTrust 2997A, HP R/T 2200 G2, Infosec XP 1000
and XP 500, Ippon Back Power Pro (serial and USB), Kebo 1200D/D Series,
Liebert PowerSure Personal XT, MGE Office Protection Systems Protection
Station, Neus 400va and 600va, Phasak 400VA and 600VA, Plexus 500VA, Powercom
Black Knight PRO / King PRO and Imperial, PowerKinetics BlackOut Buster,
Sweex 1000 USB, UNITEK Alpha 500, WinPower CPM-800.
- NUT now embeds Python client support through the PyNUTClient module and the
NUT-Monitor application. Both are from David Goncalves, and are still
available from http://www.lestat.st.
For more information, refer to scripts/python/README.
- the dummy-ups driver now support a "repeater" mode. This allows it to act as
a NUT client, and to forward data. This can be useful for supervision and
load sharing purposes.
- tcp-wrappers support has been added to the upsd server, to grant users access
by source IP for commands that require to be logged into the server. This
replaces the previous internal implementation (ACL in upsd.conf).
- the nut.conf file has been introduced to standardize startup configuration
across the various systems.
- NUT now ships a bash completion function for 'upsc' command
(scripts/misc/nut.bash_completion). Simply copy it to /etc/bash_completion.d
- many internal changes to improve maintenability, while lowering the
maintenance cost (thus allowing developers to focus on what matters: the
code!). Examples of this are:
- the USB information automatic extraction to generate the various USB helper
files,
- the upsdrv_info_t structure to track more driver information, and remove
the need for the upsdrv_banner() function
- common USB code refactoring, as it is done for the serial functions.
- tons of bugfixes, cleanup and improvements to make NUT stronger than ever!
---------------------------------------------------------------------------
Release notes for NUT 2.2.2 - what's new since 2.2.1:
- support for new devices: APC BACK-UPS XS LCD, Atlantis Land,
Mustek Powermust Office 650, Oneac XAU models, Powerware PW5115 and
PW9120 (USB), Nitram Elite 2005
- Integrated Power Management (NUT HAL integration) has reached a
major milestone: it is now the most advanced UPS integration into
Power Management layer known in existing OSs. It has received many
corrections and improvements, and allows to PowerOff the UPS at the
end of a power cycle (which is the most important feature, not
supported on other systems).
The various files are now installed into the correct location.
- the usbhid-ups driver has received attention. Most notably, the
shutdown handling has been reworked, and support for MGE UPS SYSTEMS
3 phases units has been added.
- snmp-ups now supports MGE* Environment Sensor (ref 66 846).
The ambient.temperature reporting has also been fixed for units
other than APC.
- the netxml-ups driver has appeared to support MGE* network HTTP/XML
cards.
- NUT now distributes by default the shared version of libupsclient
(version 1.0.0), and use this for the provided clients (upsmon, upsc,
upsrw, upscmd). This is part of an effort to reduce NUT's footprint,
both on disk and in memory.
- powerpanel has reach a new step toward the replacement of nitram and
cpsups drivers. The final step is scheduled for NUT 2.4.
- many changes, cleanup and fixes to the NUT core and various drivers.
---------------------------------------------------------------------------
Release notes for NUT 2.2.1 - what's new since 2.2.0:
- support for new devices: all MGE Office Protection Systems units,
Advice TopGuard 2000, Belkin F6H375-USB, Dynamix UPS1700D, Effekta RM2000MH,
Jageson Technology Jasuny USPS, Powercom SMK-1500A and SXL-1500A,
PowerWalker Line-Interactive VI 400/800 and 600, Powerware 9110,
UNITEK Alpha 2600, UPSonic CXR1000, some vintage serial APC UPSs.
- the usbhid-ups driver has been improved, and fixed in many areas, through
a backport of the development (trunk) version.
- the udev rules, for Linux hotplug support of the USB UPSs, has been
updated to support kernel newer than 2.6.22.
- the megatec and megatec_usb drivers have also been backported from the
development (trunk) version.
- the client development files have also received some care:
the upsclient pkg-config file has been fixed, and the upsclient.h
file allows older NUT clients to continue using the UPSCONN structure.
---------------------------------------------------------------------------
Release notes for NUT 2.2.0 - what's new since 2.0.5:
- The new build infrastructure, using automake, is now used.
This has major impact on the compilation and installation procedures,
and thus on the NUT packaging.
For more information, refer to UPGRADING and packaging/debian/ for
an example of migration.
- NUT now provides support for FreeDesktop Hardware Abstraction Layer
(HAL) which brings full Plug And Play experience to USB UPS owners.
For more information, refer to docs/nut-hal.txt.
- support for new devices: Ablerex 625L, ActivePower 400VA, 2000VA;
Belkin Home Office F6H350-SER, F6H500-SER, F6H650-SER; Belkin Office
Series F6C550-AVR; Belkin Universal UPS F6C100-UNV (USB), F6C1100-UNV
(USB), F6C1200-UNV (USB), F6H350deUNV (serial), F6H350ukUNV (serial),
F6H650ukUNV (serial); Compaq R3000h; Cyber Power Systems PR2200;
Dynex DX-800U; Geek Squad GS1285U; Krauler UP-M500VA; Mecer ME-2000;
MGE UPS SYSTEMS Ellipse MAX; Online Zinto D; PowerTech SMK-800; SVEN
Power Pro+ series, Power Smart RM 2000; Tripp-Lite SmartOnline
SU1500RTXL2ua, smart2200RMXL2U.
- added IPv6 support,
- the newmge-shut driver has appeared. This one uses the same HID core
as usbhid-ups, but communicate over a serial link. It will eventually
replace the current mge-shut driver.
- client commands (upsc, upsrw and upscmd): hostname is now optional,
and defaults to "localhost"
- many drivers have been improved and have received bug fixes:
powerpanel, megatec, megatec_usb, safenet, tripplite_usb, gamatronic,
- the hotplug and udev scripts, in charge of setting the right
permissions on the USB devices, are now installed automatically
when appropriate.
- more generally, the NUT core and documentation, including the manpages,
have been improved and updated.
---------------------------------------------------------------------------
Release notes for NUT 2.0.5 - what's new since 2.0.4:
This release is a backport of the development version. Many changes
have already been backported previously. Thus it is more a
synchronisation release, though it includes many bugfixes and support
for new models.
- support for new devices: APC Smart-UPS with 6TI firmware; Belkin
Small Enterprise F6C1500-TW-RK; Compaq R3000 XR, R5500 XR; Cyber
Power 550SL, 725SL, 685AVR, 800AVR, 1200AVR, AE550; Eltek; Inform
GUARD; Microsol Rhino; Opti-UPS PowerES 420E; PowerMan RealSmart,
BackPro; Powerware PW9315 3-phase; SOLA 305; Tripp-Lite
SMART550USB, SMART2200RMXL2U, OMNI1000LCD, OMNI900LCD, OMNI650LCD,
1500 LCD, AVR550U; Viewsonic PowerES 420E.
- bcmxcp: added 3-phase support
- megatec: better hardware support, more instant commands
- mge-hid: support more instant commands
- newhidups: fixed APC and Tripp Lite bugs, various memory bugs,
improved report buffering, improved Solaris support, added
'-x explore' option for easy diagnosis of new devices
- solis: shutdown programming, support new cables, Solaris support
- tripplite_usb: updated SMARTPRO support, fixed OL/OB reporting,
better error handling, some memory bugs
- new dummy-ups driver simulator
- added HTML interface for access to CGI scripts
---------------------------------------------------------------------------
Release notes for NUT 2.0.4 - what's new since 2.0.3:
- The newhidups critical bug (segmentation fault) has been fixed. It has
also received some more care, like buxfixes and new models support and
enhancement for Solaris.
[Peter Selinger and Arnaud Quette]
- A bug has been fixed in NUT core to support resuming from suspend-to-disk.
This should also fix other similar issues, like time synchronisation
through the NTP - Network Time Protocol.
[Arjen de Korte]
- The mge-shut driver now better detects the Low Battery status, support
new models and fixes some wrong status and data. It also fixes some
issue where the UPS wasn't restarting (refer to mge-shut manpage).
[Arnaud Quette]
- The genericups custom configuration through ups.conf is working again
[Arjen de Korte]
- The genericups driver type 22 also support CyberPower 725SL
(and maybe others SL models)
[David Kaufman]
- The new megatec driver, which will replace a bunch of drivers by nut 2.2
(refer to docs/megatec.txt and UPGRADING) has been backported from the
trunk (Development tree). The powermust driver has also received some
attention.
[Carlos Rodrigues]
- The new rhino driver was added to support Microsol Rhino UPS hardware
The solis has also been improved for solaris compatibility, and
internal / external shutdown programming. solis can now save external
shutdown programming to ups, and support new cables for solis 3
[Silvino B. Magalhães]
- Several fixes and improvements have been made to upsrw, upsset,
cpsups, tripplite_usb and the FAQ.
[Arjen de Korte and Charles Lepple]
---------------------------------------------------------------------------
Release notes for NUT 2.0.3 - what's new since 2.0.2:
- The recent and major newhidups changes have been backported from the
Development tree. It now:
- supports models from MGE UPS SYSTEMS, APC and Belkin. Mustek and Unitek
units are also recognized for development purpose,
- handles better device reopening, after a disconnection,
- handles multiple devices, with several parameters to find the right UPS.
[Peter Selinger, Charles Lepple and Arnaud Quette]
- The bcmxcp_usb driver has been added to support Powerware USB units.
[Wolfgang Ocker and Kjell Claesson]
- The tripplite_usb driver has been added to support Tripp Lite USB units.
[Charles Lepple]
- The sec driver is back as gamatronic
[Gamatronic, Nadav Moskovitch]
- The genericups driver has received official care from Gamatronic
to add support for the Gamatronic UPS with alarm interface.
[Gamatronic, Nadav Moskovitch]
- The powermust driver now supports Soyntec Sekury C 500 and C 800 units.
[Hanno Borns]
- The mge-shut driver has received a bit of attention too, and enhance
ups.model retrieval for some specific case (release 0.65)
- The drivers don't change to the "statepath" directory anymore at
initialisation time if called using -k. This avoid unneeded
failure to poweroff the UPS if /var is already unmounted.
[Gaspar Bakos]
- The belkinunv driver now supports Belkin F6C1100-UNV
[Dave Breiland]
- The isbmex driver has been upgraded to version 0.05, which fixes
various errors in formulas, add shutdown capability and revert
back baudrate to B9600 (instead of B2400), as it broke the
communication
[Ricardo Martinezgarza]
- The support of Sysgration UPGUARDS Pro650 in fentonups has
been fixed
[Simon J. Rowe]
- The packaging files for Red Hat have received various fixes
[Thomas Jarosch]
- The solis driver has been fixed to avoid a naming colision and
compile on Solaris
[Paweł Kierdelewicz]
- The snmp-ups driver has corrected the problem when exposing
certain time data.
---------------------------------------------------------------------------
Release notes for NUT 2.0.2 - what's new since 2.0.1:
- the newhidups USB driver has been improved a lot and is no more
experimental. It also now has a basic APC support, which will
soon replace the legacy hidups driver.
- The mge-utalk driver has improved its support for old units.
- The mge-shut driver has been improved for restart/shutdown
sequences which was previously blocking the serial port.
- The general MGE support has been added Pulsar EXtreme C / EX RT,
Comet EX RT, Pulsar SV, Pulsar PSX, Ellipse Office and NOVA AVR USB.
- The genericups driver now supports Generic RUPS 2000, AEC MiniGuard
UPS 700 (using Megatec M2501 cable), and Powerware 3110.
[Nick Barnes, Paul Andreassen]
- The powermust driver now supports SquareOne Power QP1000, Mustek
PowerMust 1400VA Plus and 2000VA USB.
[Carlos Rodrigues]
- The fentonups driver has been enhanced and now supports Sysgration
UPGUARDS Pro650.
[Michel Bouissou, Simon J. Rowe]
- The cpsups driver now supports MicroDowell B.Box BP 500/750/1000/1500.
[Armin Diehl]
- The snmp-ups driver now supports Socomec SNMP devices (Netvision MIB),
and Powerware ConnectUPS SNMP cards.
[Thanos Chatziathanassiou, Olli Salvia]
- The bcmxcp driver is back with support for Powerware UPSs.
[Tore Øpetveit, Kjell Claesson]
- The cyberpower driver now supports CyberPower 1000AVR.
[Dave Huang]
- The new solis driver supports Microsol units: Solis 1.0, 1.5,
2.0 and 3.0.
[Silvino B. Magalhaes]
- The apcsmart driver has fixed APC600 support.
- The etapro driver fixes brokeness due to ser_get_line use
[Marek Michalkiewicz]
- The new upscode2 driver supports Fiskars, Compaq and Powerware
devices.
[Niels Baggesen, Havard Lygre]
- The tripplite driver has fixed a battery charge bug
[Cedric Tefft]
---------------------------------------------------------------------------
Release notes for NUT 2.0.1 - what's new since 2.0.0:
- The bestuferrups driver has been forked into the new bestfcom driver
which has better handling of the inverter status alarm messages and
more.
[Kent Hill]
- Mustek UPS support returns with two drivers which have overlapping
coverage: mustek and powermust.
[powermust: Carlos Rodrigues, mustek: Martin Hajduch]
- Additional CyberPower Systems hardware is supported with the new
cpsups driver. Three recognized models are the CPS1500AVR,
CPS1100VA, and OP500TE.
[Walt Holman, Brad Sawatzky]
- The genericups driver can now generate staleness warnings in
specific cases where the UPS provides a way to test for its
presence. See the "CON" setting in ups.conf for more details.
[stan / saticed.me.uk]
- Documentation for monitoring a Back-UPS RS 500 on a system without
USB ports has been added to the cables directory.
[Martin Edlman]
- The everups driver now supports types 73-76 (NET 700/1000/1400/500-DPC)
[hunter]
- The new metasys driver supports Meta System models: Line,
HF Millennium, HF Top Line, ECO Network, ECO, Ally HF, Megaline
[BlaXwan]
- The ippon driver now allows user-defined settings for the delay
before switching off, and the delay before powering on.
[Yuri Elizarov]
- The victronups driver is now at version 0.1.9, which adds many
instant commands: calibration control, battery and front panel tests,
and bypass control.
[Gert Lynge]
- The tripplite driver has recieved a major overhaul to bring it up to
working condition for the 2.0 tree, including code cleanups, several
new variables, commands, and user-definable parameters. See
ChangeLog for more.
[Nicholas J Kain]
- The mge-utalk driver has been upgraded to version 0.81, which fixes
the lack of read-write variables and loss of sync on models which
don't support restoring settings.
[Arnaud Quette]
- The Micro Ferrups model RE is now supported by the bestuferrups
driver. The driver will also now read the ambient temperature and
will no longer constantly report the data as stale.
[Tim Thompson]
- The fentonups driver's init sequence has been reworked to work better
with some hardware, including a fix to the parser code.
[MLH]
- A workaround has been added to the hidups driver to avoid variables
which are stuck by calling HIDIOCINITREPORT in every poll.
[Stuart D. Gathman]
- SOLA 610 UPS hardware and others which do not support the ID command
may now be monitored by the bestups driver after forcing ID= in
ups.conf.
[Jason White]
- "pollinterval" is now available via driver.parameter for consistency.
[Arnaud Quette]
- The mge-shut and newhidups drivers, along with the supporting
hidparser/libhid code have received many updates, including lowering
USB bandwidth consumption, driver unbinding (only in Linux), code
cleanups, and more which can be seen in the ChangeLog file.
[Arnaud Quette]
- The fentonups driver now recognizes several more Megatec protocol
units:
SuperPower HP360, Hope-550 [Denis Zaika]
Unitek Alpha 1000is [Antoine Cuvellard]
- Some variables like uc_sigmask were renamed to avoid clashes with
symbols on systems like HP/UX.
- All man pages have been reworked to switch literal "-" characters to
hyphens or "\-" as appropriate.
[Shaul Karl]
- upssched's CANCEL events were broken following the change to
text-based socket messages in 1.5 and have been fixed.
[Steven Schoch]
- Calls to varargs functions with raw strings from the config files
without an intervening "%s" have been fixed in upsmon, upssched,
snmp-ups and upsd.
[Ulf Harnhammar]
---------------------------------------------------------------------------
Release notes for NUT 2.0.0 - what's new since 1.4.x:
- The new naming scheme for variables and commands (introduced in 1.4)
is now mandatory. The 1.4 tree supported both the old (STATUS) and
the new (ups.status) as a transitional release, and now that time is
over.
This means that 2.0 is generally smaller than 1.4 code, since the
interim compatibility hacks have been removed.
- New serial handling code has been added, with greatly simplified
operations. The old mess involving repeated calls to sigaction,
alarm, and read has been condensed to a select-read loop.
This change allows drivers which don't do any serial communications
at all (hidups, snmp-ups) to drop that baggage, so they are a bit
smaller when compiled.
- The drivers now recognize "chroot=' and 'user=' in the global section
of ups.conf. This means you don't have to use -r and -u when
starting upsdrvctl.
- upsmon now supports the -K argument to check for the presence of the
POWERDOWNFLAG file. If it exists and contains the magic string, then
upsmon will exit(EXIT_SUCCESS). Otherwise, it will
exit(EXIT_FAILURE).
This feature can be used to simplify shutdown scripts, since now you
don't have to keep the script in sync with the upsmon.conf.
- Many small things like signed value comparisons, int vs. size_t and
proper use of const/struct were fixed throughout the source. These
were mostly for correctness, but a few potential bugs involving very
big or very small numbers were fixed at the same time.
- The access control system in upsd.conf has been reworked and
simplified. Since access levels have become meaningless in recent
releases, the new system is just ACCEPT <acl> or REJECT <acl>.
If you are upgrading from a previous version of the software, you
will have to edit your upsd.conf to use this method. See
the UPGRADING file for more details.
- The build process now halts when make fails in one of the
subdirectories.
[Petter Reinholdtsen, Charles Lepple]
- Helper data for using upsclient via pkgconfig is now created if
pkgconfig is detected when configure runs.
[Arnaud Quette]
- The polling interval in drivers may now be set with 'pollinterval'
in ups.conf.
[Gabriel Faber]
- Blazer UPS equipment is now supported with the blazer driver.
[Phil Hutton]
- Energizer USB UPS hardware is now supported on Linux with a new
experimental driver.
[Viktor T. Toth]
- The newhidups driver has been merged as the first step towards
portable USB UPS support. This will eventually replace the old
Linux-only hidups driver. The newhidups driver is tagged
experimental since it is under active development.
[Arnaud Quette, Charles Lepple]
- The newapc driver has been renamed to apcsmart, replacing the old
driver with that name. If you used the newapc driver, be sure to
delete the old binary and fix your ups.conf.
- The apcsmart driver now supports asynchronous notification data
from the hardware, which means it can wake up as soon as something
happens. This affects the OL/OB/LB/RB data in ups.status, and
generally reduces the latency in dispatching status changes by a few
seconds.
- The apcsmart driver can now support quirky hardware which does not
provide the usual listing of valid command characters. This feature
is necessary to monitor new models like the APC CS 350 and old ones
like the Matrix 5000. It also now has sdtype=4 to handle the strange
shutdown behavior on the CS series.
- The belkin driver now works around broken firmware version 001,
avoiding a lengthy delay at startup. It also implements the shutdown
sequence differently, and should actually work on more hardware now.
- The bestups driver has been slowed down to play nicer with the
hardware, and is much more reliable as a result. Among other things,
it should always detect the UPS on the first try, meaning no more
"dot dot dot" when it starts.
- The cyberpower driver is no longer tagged experimental, and now
supports powering off the load. It also supports battery tests via
instcmds.
- Effekta MT 2000 RM hardware is now supported by the fentonups driver.
[christoph moar]
- The new safenet driver supports UPS hardware that uses the protocol
of the same name. This includes models from many manufacturers,
including Fairstone, Fenton, Gemini, Powerwell, Repotec, Soltec and
Sweex. See the README or driver.list for the full details.
[Arjen de Korte]
- The genericups driver now has type 20 to monitor the Powerware 5119
RM. See http://lists.exploits.org/ups/Oct2003/00052.html.
[Daniel Thompson]
- The belkinunv driver has been added to allow monitoring Belkin
Universal UPS hardware.
[Peter Selinger]
- Cyber Power Systems 1100AVR hardware which has a different protocol
than the existing binary type (supported by 'cyberpower') is now
supported by the experimental cyberpower1100 driver.
[Walt Holman]
- upsdrvctl now returns success or failure information in the exit
code. Any failure during a requested operation will result in a
nonzero value (specifically EXIT_FAILURE).
---------------------------------------------------------------------------
Release notes for NUT 1.4.0 - what's new since 1.2.x:
- The drivers and upsd now communicate over Unix domain sockets instead
of state files, shared memory, or state files with mmap. This change
makes many things possible, including the new dynamic variable and
command naming scheme described below.
There is a new development tool called sockdebug in the server
directory for debugging driver-server communications on the sockets.
- The old static variable scheme has been replaced by a new dynamic
implementation. Vague names have been turned into meaningful names
that fit into an organized system. UTILITY is now input.voltage.
OUTVOLT is now output.voltage.
This also applies to the names of instant commands. BTEST1 is
test.battery.start, and BTEST0 is test.battery.stop.
The old names are still supported for compatibility with older
clients. This compatibility mode will be maintained throughout
the 1.4 series, and will be gone by the release of 2.0. Users
with older clients are encouraged to upgrade their software
during this time.
- The network protocol has been expanded to handle these new names.
Older functions which only apply to the old names will continue to
be supported through the 1.4 series.
- The drivers and server (upsd) can now change their user ids and
chroot themselves with the new -u and -r arguments. This lets you
create a "chroot jail" with the bare minimum components.
This technique is used to provide a higher degree of security. If
someone exploited upsd to get a shell somehow, they would be stuck
in the jail.
- upssched now explicitly confirms reception of timer commands before
exiting. This was done to avoid a race where one process would
exit right when another one was starting. The second one would
believe its command had been handled when it had been lost.
- upslog has been reworked to use standard getopt parsing to provide
the monitoring settings. The old way of specifying arguments is
still supported for backwards compatibility.
upslog has also been changed to only parse the format string once,
rather than doing it every time through the loop. This should
provide a minuscule drop in CPU utilization.
- Usernames are now required in upsmon and upsd. This means that you
must add a username to your MONITOR lines in upsmon.conf and then
create a matching user in upsd.users.
Installations from the 1.2 era probably already use usernames, so
this mostly affects those from 1.0 and before.
- Drivers are now pinged regularly by upsd when they aren't posting
updates about the UPS status. This provides another check in the
data validation process. If upsd fails to get a response within
a few seconds, the UPS will be marked stale.
- A few minor memory leaks were discovered with valgrind and squashed.
- upsstats now reuses connections to upsd when cycling through multiple
entries in the hosts.conf. This makes things a bit faster and
avoids some of the noise in the syslog.
This only applies to entries that are adjacent. To take advantage
of this feature, you may have to rearrange them.
MONITOR ups-1@host-1 ...
MONITOR ups-1@host-2 ...
MONITOR ups-2@host-2 ...
MONITOR ups-3@host-3 ...
Connection reuse for nonadjacent entries may be considered in the
future.
- upsd now warns about insecure configuration files at startup.
These files (upsd.conf, upsd.users, and the certfile) should
only be readable by upsd. Never make them world-readable.
- The programs no longer print "shutting down" when they are just
exiting. This was changed to avoid confusion about the term, since
"shutting down" has a special meaning in UPS software.
- Signal handlers no longer do any significant amount of work. Some of
the programs used to do numerous things in there, raising concerns
about reentrancy. They now set flags and allow the main loop to do
the actual work from there.
- A bug in upsmon where NOTIFYFLAG settings could be ignored was fixed.
- Group handling has been changed. configure no longer accepts
--with-group, and the programs no longer setgid() to a hardcoded
value. They now setgid() to the primary group of whatever the
user value may be.
This may be compiled in with --with-user as before, and many programs
accept -u to override it at runtime.
- The state path is no longer created during 'make install'. Users
are now expected to create it themselves. This removes a lot of
evil complexity from the build and install sequences.
- upsd no longer implements the DROP access command, as it
could confuse the clients by getting them out of sync. DROP is now
implemented as DENY, which sends an error message. If you use DROP,
you should change it to DENY rather than relying on this
compatibility measure.
- The belkin driver no longer reports OFF and OL at the same time.
- The bestups driver no longer sleeps during polls, which makes it
more responsive to things like instant commands.
- The cyberpower driver now has much better hardware detection code
and no longer freezes at startup under some conditions. It also now
supports the shutdown function. Instant commands for shutdowns and
battery tests were also added.
- The dummyups testing driver has been removed. The dummycons testing
driver can do everything that dummyups once did and much more.
dummycons is also now built by default for easier testing.
- The newapc driver has been reworked to take advantage of the new
internal driver state functions. Some variables without an obvious
purpose were dropped.
- The newapc driver now sends all five bytes when using sdtype 1.
Previously it didn't send the entire string, and it didn't work.
[Don Lewis]
- The hidups driver has been expanded to allow for setting variables,
a shutdown sequence, and more.
[Arnaud Quette]
- The mge-utalk driver had trouble establishing communications in
some cases due to the RTS line being set. This has been fixed.
The mge-shut driver has been added to the tree, and has replaced
the older mge-ellipse driver.
[Arnaud Quette, Philippe Marzouk]
- Outlet-level control has been defined in the variable tree, and will
be added to drivers where the hardware supports it. This can be
used to shut down some components earlier than others to prolong
your runtime on battery.
This is supported in the mge-shut driver now, and may show up in
others before long.
[Arnaud Quette]
- KIN-2200AP hardware is now recognized by the powercom driver.
This change may also support other KIN-xxxxAP equipment.
[Preston A. Elder]
- The 1.1kVA UPS is now supported by the bestuferrups driver. This
driver was also changed to allow easy addition of more models
in the future.
[Bob Apodaca]
- The fentonups driver can now handle devices which implement the
"I" detection differently, and now supports the Giant/WELI 500
as a result.
[Joon Guillen]
- The serial number of the UPS being monitored can now be specified
with serial= in ups.conf in the genericups driver.
[Shaul Karl]
- The newapc driver now sends ESC to break out of menus when the
initial detection fails. Some new APC models have interactive menus
on the serial port, and the driver couldn't handle them before.
- The snmp-ups driver now reports ambient temperature and humidity
data for APC equipment. It also now supports the shutdown.reboot and
shutdown.reboot.graceful commands.
[Dmitry Frolov]
- The list of supported variables and commands in the snmp-ups driver
has been expanded.
[Arnaud Quette, J.W. Hoogervorst]
- Various drivers now report bypass mode with the BYP status word.
[Arnaud Quette]
- Energy Sistem equipment is now supported with the esupssmart driver.
[Antonio Trujillo Coronado]
- The Tripp-Lite SU series (SmartOnline) is supported with the new
tripplitesu driver.
[Allan Hessenflow]
- The HP PowerTrust A2994A is now recognized by the hp driver.
[Jan Sporbeck]
- Many drivers were cleaned up to perform basic sanity checks on the
status data before using it.
- An explicit cleanup function has been added to the driver core to
ensure that all dynamic resources are freed before exiting. This
is part of the larger process to check for memory leaks and other
bad things.
[Arnaud Quette]
- upsd now provides variable descriptions from an auxiliary file.
This file is optional, which allows for a smaller memory footprint.
It can also be edited for localization or other customizations.
- upsimage and upsstats can now render BATTVOLT data.
[Andrew R. Ghali]
- String handling has been cleaned up throughout the tree. Calls to
functions like strcpy and strcat were either replaced with other
(range-checking) functions or were rewritten to avoid it.
- Many compile-time defaults may now be overridden at runtime. In
the environment NUT_CONFPATH and NUT_STATEPATH may be used.
upsdrvctl has been changed to execve to pass these along to the
drivers. ups.conf now supports driverpath=, and upsd.conf supports
DATAPATH.
[Bryan Henderson]
- The configure --with-gd switches now actually do something useful
when gd has been installed outside the default search directories.
[Patrik Schindler]
- The inline keyword is now handled properly on systems which do not
support it or have it specified as another name. This was breaking
compiles on some systems.
[Petter Reinholdtsen]
---------------------------------------------------------------------------
Release notes for NUT 1.2.2 - what's new since 1.2.1:
- The snmp-ups driver has been upgraded and expanded. It now supports
multiple MIBs, meaning it can handle RFC 1628, APCC, and MGE
equipment. You can pick the right one with "mibs=" in ups.conf.
Support for setting variable and instant commands is also available.
[Arnaud Quette and Dmitry Frolov]
- The powernet driver has been upgraded. It now supports more
variables, has cleaner logging, and may now be considered stable.
[Dmitry Frolov]
- The hidups driver now supports physical port IDs. This avoids most
of the problems where the hiddev* names can jump around too easily.
It will now stay in the same place as long as you keep it plugged
into the same physical port. See the ChangeLog file for more details.
[David Brownell]
- The hidups driver now also supports the MFR variable on APC
Back-UPS ES equipment.
[Jonathan A. Davis]
- The sms driver has been updated to version 0.70.
[Marcio Gomes]
- The bestups driver now recognizes Best Power Axxium Rackmount
equipment.
[Ales Casar]
- The liebert driver now uses O_NONBLOCK, and should now work
consistently on OpenBSD as a result.
[Alex Cichowski]
- The liebert driver also now uses debouncing logic on the status
lines. It was possible to get false readings that would start a
shutdown or just annoy users with excessive onbatt/online notify
messages. The new code forces the status to settle down for 3 polls
before accepting the new value.
This means that very short power events may not be detected. The
alternative is having your machine shut down just because it decided
to wiggle over to OB LB for a few seconds.
- upsmon has had the disconnect logic fixed so the "communications
lost" (COMMBAD) notify will actually go out when the connection
fails.
[Steve Monett]
- upssched now uses a lock file to prevent a race where two could
start at the same time. The second upssched would "win", and the
first one would be unreachable. This had the side-effect of not
being able to cancel timers on the first one.
If you use upssched, you must define the LOCKFN directive when
upgrading to this version, or it will not work.
[Gaspar Bakos]
- The packaging and scripts for Red Hat systems have been updated.
[Antonino Albanese]
- upsd is now a bit more lenient about access levels in the
'numlogins' check, which is what caused the problem in upsmon
(next item).
- upsmon no longer gets stuck in slavesync() when upsd is configured
to drop certain queries. This usually happened at the worst
possible time: in the middle of a shutdown.
[John David Garza]
- The upsclient functions now do more sanity checking on data from
upsd so a short read won't return garbage to the callers.
- upsset now works properly with ENUM/VARTYPE values for multiple
UPSes on a single upsd.
[Dmitry Frolov]
- Various portability fixes for building on SGI were applied.
[Andrea Suatoni]
- upsd no longer tries to reference a deleted client structure if the
client disconnects at the wrong time. Previously, it tried to use
that pointer after the sendback() function had already failed on
write and deleted the client. This could cause upsd to segfault
depending on what areas were accessed.
[Patrik Schindler]
---------------------------------------------------------------------------
Release notes for NUT 1.2.1 - what's new since 1.2.0:
- The sms driver is back, with support for Microlink Manager III
hardware. [Marcio Gomes]
- Fideltronik Ares Series hardware is now supported as genericups type
19. [Tomek Orzechowski and Arkadiusz Mikiewicz]
- The drivers no longer silently drop instant commands or set commands
from upsd that happen to get fragmented in transit.
[linux@horizon.com]
- The old multilink driver is back with a new name: liebert. It
supports Liebert UPStation GXE hardware with the contact-closure
cable. This is currently an experimental driver as there is no
way to power down the load.
- configure now picks up the right flags for gd automatically if gd
2.0.8 or higher is installed. This greatly simplifies the CGI build
process for most users.
- Shutdowns on FreeBSD using the genericups driver should work again.
[Petri Riihikallio]
---------------------------------------------------------------------------