tripplite \- Driver for Tripp\-Lite SmartPro UPS equipment
.SH"NOTE"
.sp
This man page only documents the hardware\-specific features of the tripplite driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&.
.SH"SUPPORTED HARDWARE"
.sp
This driver should work on the SmartPro line, including the SMART700 and SMART700SER\&. It only supports SmartPro models that communicate using the serial port\&.
.SH"EXTRA ARGUMENTS"
.sp
This driver supports the following optional settings in the \fBups.conf\fR(5):
.PP
\fBoffdelay\fR=\fInum\fR
.RS4
Time to wait before the UPS is turned off after the kill power command is sent\&. The default value is 64 (in seconds)\&.
.RE
.PP
\fBrebootdelay\fR=\fInum\fR
.RS4
Set the timer before the UPS is cycled after the reboot command is sent\&. The default value is 64 (in seconds)\&.
.RE
.PP
\fBstartdelay\fR=\fInum\fR
.RS4
Set the time that the UPS waits before it turns itself back on after a reboot command\&. The default value is 60 (in seconds)\&.
.RE
.SH"KNOWN ISSUES AND BUGS"
.sp