70 lines
2.1 KiB
Groff
70 lines
2.1 KiB
Groff
|
.TH "BCMXCP" "8" "Wed Dec 31 2008" "" "Network UPS Tools (NUT)"
|
||
|
.SH "NAME"
|
||
|
bcmxcp \- Driver for UPS'es supporting the serial BCM/XCP protocol
|
||
|
.SH "NOTE"
|
||
|
This man page only documents the hardware\(hyspecific features of the
|
||
|
bcmxcp driver. For information about the core driver, see
|
||
|
\fBnutupsdrv\fR(8).
|
||
|
|
||
|
.SH "SUPPORTED HARDWARE"
|
||
|
This driver should recognize all serial BCM/XCP\-compatible UPS'es. It has
|
||
|
been developed and tested on Powerware PW5115 and PW9120 hardware. If your UPS
|
||
|
has a USB connection, you may also consult the \fBbcmxcp_usb\fR(8) driver
|
||
|
documentation.
|
||
|
|
||
|
.SH "EXTRA ARGUMENTS"
|
||
|
This driver supports the following optional settings in the
|
||
|
\fBups.conf\fR(5).
|
||
|
|
||
|
.IP "shutdown_delay=\fIdelay\fR"
|
||
|
The number of seconds that the UPS should wait between receiving the
|
||
|
shutdown command (upsdrvctl shutdown) and actually shutting off.
|
||
|
|
||
|
.IP "baud_rate=\fIrate\fR"
|
||
|
Communication speed for the UPS. If this is set to 9600, it try to connect
|
||
|
to the UPS on 9600bps. If it fails to communicate, it go into baudhunting.
|
||
|
It start at 1200 and up to 19200. If it succeed it tell you the speed it
|
||
|
connect with. If not included in the config it default's to baudhunting.
|
||
|
|
||
|
.SH "DEFAULT VALUES FOR THE EXTRA ARGUMENTS"
|
||
|
.IP "shutdown_delay = \fI120\fR"
|
||
|
.IP "baud_rate = \fInone\fR"
|
||
|
.SH "INSTANT COMMANDS"
|
||
|
This driver supports the following Instant Commands:
|
||
|
|
||
|
.IP "shutdown.return"
|
||
|
Turn off the load and return when power is back.
|
||
|
|
||
|
.IP "shutdown.stayoff"
|
||
|
Turn off the load and remain off.
|
||
|
|
||
|
.IP "test.battery.start"
|
||
|
Start a battery test.
|
||
|
|
||
|
.IP "outlet.n.shutdown.return"
|
||
|
Turn off the load on outlet "n" and return when power is back.
|
||
|
( n is the outlet number reported by the upsc command )
|
||
|
|
||
|
.SH "TODO LIST"
|
||
|
.IP "Report UPS statistics informations"
|
||
|
BCM/XCP supports reporting of UPS statistics data.
|
||
|
|
||
|
.IP "Change settings"
|
||
|
Access the config register to change settings.
|
||
|
|
||
|
.SH "BUGS"
|
||
|
None known.
|
||
|
|
||
|
.SH "AUTHOR"
|
||
|
Tore \[/O]rpetveit <tore@orpetveit.net>
|
||
|
|
||
|
.SH "SEE ALSO"
|
||
|
.SS The core driver:
|
||
|
\fBnutupsdrv\fR(8)
|
||
|
|
||
|
.SS The USB BCM/XCP driver:
|
||
|
\fBbcmxcp_usb\fR(8)
|
||
|
|
||
|
.SS Internet resources:
|
||
|
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|