nut/man/richcomm_usb.8

36 lines
1.3 KiB
Groff
Raw Normal View History

2010-03-25 23:20:59 +00:00
.TH RICHCOMM_USB 8 "Sat Dec 27 2008" "" "Network UPS Tools (NUT)"
.SH NAME
richcomm_usb \- Driver UPS equipment using Richcomm dry\(hycontact to USB
solution
.SH NOTE
This man page only documents the specific features of the richcomm_usb
driver. For information about the core driver, see \fBnutupsdrv\fR(8).
.SH SUPPORTED HARDWARE
The Richcomm dry\(hycontact to USB solution is a generic interface that is
used to upgrade an existing (RS-232) contact closure UPS interface to USB.
As such, all the limitations of the underlying contact closure interface
apply. This means that you will only get the essentials in ups.status: OL,
OB, and LB. See also \fBgenericups\fR(8).
.SH BUGS
Most contact\(hyclosure UPSes will not power down the load if the line power
is present. This can create a race when using slave \fBupsmon\fR(8)
systems. See the \fBupsmon\fR(8) man page for more information.
The solution to both of these problems is to upgrade to a smart protocol
UPS of some kind that allows detection and proper load cycling on command.
.SH AUTHORS
Peter van Valderen <p.v.valderen at probu.nl>
Dirk Teurlings <dirk at upexia.nl>
.SH SEE ALSO
.SS The core driver:
\fBnutupsdrv\fR(8)
.SS Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/