nut/drivers/bcmxcp.h

625 lines
39 KiB
C
Raw Normal View History

2010-03-25 23:20:59 +00:00
/*
* bcmxcp.h -- header for BCM/XCP module
*/
#ifndef _POWERWARE_H
#define _POWERWARE_H
#include "timehead.h"
2012-06-01 13:55:19 +00:00
/* Have to wait at least 0,25 sec max 16 sec */
2013-11-24 15:00:12 +00:00
/* 1 second is too short for PW9120 (leads to communication errors). So we set it to 2 seconds */
2012-06-01 13:55:19 +00:00
#define PW_SLEEP 2
2010-03-25 23:20:59 +00:00
#define PW_MAX_TRY 3 /* How many times we try to send data. */
#define PW_COMMAND_START_BYTE (unsigned char)0xAB
2013-11-24 15:00:12 +00:00
#define PW_LAST_SEQ (unsigned char)0x80 /* bit flag to indicate final sequence */
#define PW_SEQ_MASK (unsigned char)0x7F /* bit mask to extract just the sequence # */
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
#define PW_ANSWER_MAX_SIZE 256
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
/* No Autorisation required */
#define PW_ID_BLOCK_REQ (unsigned char)0x31 /* Model name, ... length 1 */
#define PW_EVENT_HISTORY_LOG_REQ (unsigned char)0x32 /* List alarms that have occured. length 1 */
#define PW_STATUS_REQ (unsigned char)0x33 /* On Line, On Bypass, ... length 1-2 */
#define PW_METER_BLOCK_REQ (unsigned char)0x34 /* Current UPS status (Load, utility,...) length 1 */
#define PW_CUR_ALARM_REQ (unsigned char)0x35 /* Current alarm and event request. length 1 */
#define PW_CONFIG_BLOCK_REQ (unsigned char)0x36 /* Model serial#, ... length 1 */
#define PW_UTILITY_STATISTICS_BLOCK_REQ (unsigned char)0x38 /* List utility power quality. length 1 */
#define PW_WAVEFORM_BLOCK_REQ (unsigned char)0x3A /* Sampled waveform data. length 7 */
#define PW_BATTERY_REQ (unsigned char)0x3B /* Charging, floating, ... length 1 */
#define PW_LIMIT_BLOCK_REQ (unsigned char)0x3C /* Configuration (Bypass thresholds,...). length 1 */
#define PW_TEST_RESULT_REQ (unsigned char)0x3F /* Get the results for a system test. length 1 */
#define PW_COMMAND_LIST_REQ (unsigned char)0x40 /* Available commands. length 1 */
#define PW_OUT_MON_BLOCK_REQ (unsigned char)0x41 /* Outlet monitor request length 1 */
#define PW_COM_CAP_REQ (unsigned char)0x42 /* Request communication capabilities. length 2 */
#define PW_UPS_TOP_DATA_REQ (unsigned char)0x43 /* Request ups topology data requset. length 1 */
#define PW_COM_PORT_LIST_BLOCK_REQ (unsigned char)0x44 /* Request communication port list. length 1 */
#define PW_REQUEST_SCRATCHPAD_DATA_REQ (unsigned char)0x45 /* Request data from scratchpad. length 2*/
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
/* Need autorisation before these commands */
#define PW_GO_TO_BYPASS (unsigned char)0x88 /* Transfer load from inverter to bypass. length 1 or 3 */
#define PW_UPS_ON (unsigned char)0x89 /* UPS on command. length 1-2 */
#define PW_LOAD_OFF_RESTART (unsigned char)0x8A /* Delayed LoadPowerOff & Restart command. length 2-4 */
#define PW_UPS_OFF (unsigned char)0x8B /* UPS off command. length 1-2 */
#define PW_DECREMENT_OUTPUT_VOLTAGE (unsigned char)0x8C /* Decrease output voltage. length 1 */
#define PW_INCREMENT_OUTPUT_VOLTAGE (unsigned char)0x8D /* Increase output voltage. length 1 */
#define PW_SET_TIME_AND_DATE (unsigned char)0x90 /* Set the real-time clock inside UPS. length 8 */
#define PW_UPS_ON_TIME (unsigned char)0x91 /* Scheduled UPS on in n minutes. length 3-4 */
#define PW_UPS_ON_AT_TIME (unsigned char)0x92 /* Schedule UPS on at specified date and time. length 7-8 */
#define PW_UPS_OFF_TIME (unsigned char)0x93 /* Scheduled UPS off in n minutes. length 3-4 */
#define PW_UPS_OFF_AT_TIME (unsigned char)0x94 /* Schedule UPS off at specified date and time. length 7-8 */
#define PW_SET_CONF_COMMAND (unsigned char)0x95 /* Set configuration command. length 4 */
#define PW_SET_OUTLET_COMMAND (unsigned char)0x97 /* Set outlet parameter command length 5. not in 5115 */
#define PW_SET_COM_COMMAND (unsigned char)0x98 /* Set communication parameter command. length 5 */
#define PW_SET_SCRATHPAD_SECTOR (unsigned char)0x99 /* Write data to scratchpad. length 3 or 18 */
#define PW_SET_POWER_STRATEGY (unsigned char)0x9A /* Set the power strategy. length 2 */
#define PW_SET_REQ_ONLY_MODE (unsigned char)0xA0 /* Set request only mode command. length 1 */
#define PW_SET_UNREQUESTED_MODE (unsigned char)0xA1 /* Set unrequested mode command. length 1 */
#define PW_INIT_BAT_TEST (unsigned char)0xB1 /* Initiate battery test command. length 3 */
#define PW_INIT_SYS_TEST (unsigned char)0xB2 /* Initiate general system test command. length 2 */
#define PW_SELECT_SUBMODULE (unsigned char)0xCE /* Select a sub module. length 2-7 */
#define PW_AUTHORIZATION_CODE (unsigned char)0xCF /* Authorization code. length 4 or 7 */
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
/* Define the XCP system test */
#define PW_SYS_TEST_GENERAL (unsigned char)0x01 /* Initiate General system Test */
#define PW_SYS_TEST_SCHEDULE_BATTERY_COMMISSION (unsigned char)0x02 /* Schedule Battery Commissioning Test */
#define PW_SYS_TEST_ALTERNATE_AC_INPUT (unsigned char)0x03 /* Test Alternate AC Input */
#define PW_SYS_TEST_FLASH_LIGHTS (unsigned char)0x04 /* Flash the Lights Test */
#define PW_SYS_TEST_REPORT_CAPABILITIES (unsigned char)0xFF /* Report Systems Test Capabilities */
2011-09-29 18:14:46 +00:00
/* Outlet operations */
2013-11-24 15:00:12 +00:00
#define PW_ALL_OUTLETS 0
#define PW_AUTO_OFF_DELAY 1
#define PW_AUTO_ON_DELAY 2
2011-09-29 18:14:46 +00:00
/* 0 means Abort countdown */
2013-11-24 15:00:12 +00:00
#define PW_TURN_OFF_DELAY 3
#define PW_TURN_ON_DELAY 4
2011-09-29 18:14:46 +00:00
2015-04-30 13:53:36 +00:00
/* Config vars*/
#define PW_CONF_BYPASS_FREQ_DEV_LIMIT 0x01
#define PW_CONF_LOW_DEV_LIMIT 0x02
#define PW_CONF_HIGH_DEV_LIMIT 0x03
#define PW_CONF_PHASE_DEV_LIMIT 0x04
#define PW_CONF_LOW_BATT 0x05
#define PW_CONF_BEEPER 0x06
#define PW_CONF_RETURN_DELAY 0x07
#define PW_CONF_RETURN_CAP 0x08
#define PW_CONF_MAX_TEMP 0x0a
#define PW_CONF_NOMINAL_OUT_VOLTAGE 0x0b
#define PW_CONF_SLEEP_TH_LOAD 0x0d
#define PW_CONF_SLEEP_DELAY 0x0e
#define PW_CONF_BATT_STRINGS 0x0f
#define PW_CONF_REQ 0xff
2010-03-25 23:20:59 +00:00
/* Config block offsets */
2013-11-24 15:00:12 +00:00
#define BCMXCP_CONFIG_BLOCK_MACHINE_TYPE_CODE 0
#define BCMXCP_CONFIG_BLOCK_MODEL_NUMBER 2
#define BCMXCP_CONFIG_BLOCK_MODEL_CONF_WORD 4
#define BCMXCP_CONFIG_BLOCK_INPUT_FREQ_DEV_LIMIT 6
#define BCMXCP_CONFIG_BLOCK_NOMINAL_OUTPUT_VOLTAGE 8
#define BCMXCP_CONFIG_BLOCK_NOMINAL_OUTPUT_FREQ 10
#define BCMXCP_CONFIG_BLOCK_OUTPUT_PHASE_ANGLE 12
#define BCMXCP_CONFIG_BLOCK_HW_MODULES_INSTALLED_WORD1 14
#define BCMXCP_CONFIG_BLOCK_HW_MODULES_INSTALLED_BYTE3 16 /* KEEP THIS UNTILL PARSING OK. USE THIS BYTE. */
#define BCMXCP_CONFIG_BLOCK_HW_MODULES_INSTALLED_WORD2 16
#define BCMXCP_CONFIG_BLOCK_HW_MODULES_INSTALLED_WORD3 18
#define BCMXCP_CONFIG_BLOCK_HW_MODULES_INSTALLED_WORD4 20
#define BCMXCP_CONFIG_BLOCK_BATTERY_DATA_WORD1 22 /* Undefined at this time.*/
#define BCMXCP_CONFIG_BLOCK_BATTERY_DATA_WORD2 24 /* Per cell inverter shutdown voltage at full rated load. (volt/cell)* 100 */
#define BCMXCP_CONFIG_BLOCK_BATTERY_DATA_WORD3 26 /* LOW BYTE Number of battery strings. HIGH BYTE undefined at this time.*/
#define BCMXCP_CONFIG_BLOCK_EXTENDED_BLOCK_LENGTH 47
#define BCMXCP_CONFIG_BLOCK_PART_NUMBER 48
#define BCMXCP_CONFIG_BLOCK_SERIAL_NUMBER 64
2010-03-25 23:20:59 +00:00
2015-04-30 13:53:36 +00:00
/*Battery block offsets*/
#define BCMXCP_BATTDATA_BLOCK_BATT_TEST_STATUS 0
#define BCMXCP_BATTDATA_BLOCK_BATT_VOLTS_T1 1
#define BCMXCP_BATTDATA_BLOCK_BATT_VOLTS_T2 5
#define BCMXCP_BATTDATA_BLOCK_TEST_DURATION 9
#define BCMXCP_BATTDATA_BLOCK_UTIL_VOLT 10
#define BCMXCP_BATTDATA_BLOCK_INPUT_CURRENT 14
#define BCMXCP_BATTDATA_BLOCK_NUMBER_OF_STRINGS 18
/*BATT_TEST_STATUS for external strings (1 byte each) if BCMXCP_BATTDATA_BLOCK_NUMBER_OF_STRINGS == 0 no external test statuses at all*/
/*next - number of ABM Statuses - at least 1 for internal batteries*/
2010-03-25 23:20:59 +00:00
/* Index for Extende Limits block offsets */
2013-11-24 15:00:12 +00:00
#define BCMXCP_EXT_LIMITS_BLOCK_NOMINAL_INPUT_VOLTAGE 0
#define BCMXCP_EXT_LIMITS_BLOCK_NOMINAL_INPUT_FREQ 2
#define BCMXCP_EXT_LIMITS_BLOCK_NOMINAL_TRUE_POWER 4
#define BCMXCP_EXT_LIMITS_BLOCK_COMM_SPEC_VERSION 6
#define BCMXCP_EXT_LIMITS_BLOCK_FREQ_DEV_LIMIT 8
#define BCMXCP_EXT_LIMITS_BLOCK_VOLTAGE_LOW_DEV_LIMIT 10
#define BCMXCP_EXT_LIMITS_BLOCK_VOLTAGE_HIGE_DEV_LIMIT 12
#define BCMXCP_EXT_LIMITS_BLOCK_PHASE_DEV_LIMIT 14
#define BCMXCP_EXT_LIMITS_BLOCK_LOW_BATT_WARNING 16
#define BCMXCP_EXT_LIMITS_BLOCK_HORN_STATUS 17
#define BCMXCP_EXT_LIMITS_BLOCK_MIN_INPUT_VOLTAGE 18
#define BCMXCP_EXT_LIMITS_BLOCK_MAX_INPUT_VOLTAGE 20
#define BCMXCP_EXT_LIMITS_BLOCK_RETURN_STAB_DELAY 22
#define BCMXCP_EXT_LIMITS_BLOCK_BATT_CAPACITY_RETURN 24
#define BCMXCP_EXT_LIMITS_BLOCK_AMBIENT_TEMP_LOW 25
#define BCMXCP_EXT_LIMITS_BLOCK_AMBIENT_TEMP_HIGE 26
2015-04-30 13:53:36 +00:00
#define BCMXCP_EXT_LIMITS_BLOCK_SLEEP_TH_LOAD 29
#define BCMXCP_EXT_LIMITS_BLOCK_SLEEP_DELAY 30
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
/* Indexes for meter map */
#define BCMXCP_METER_MAP_OUTPUT_VOLTS_AB 0 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VOLTS_BC 1 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VOLTS_CA 2 /* mapped */
#define BCMXCP_METER_MAP_INPUT_VOLTS_AB 3 /* mapped */
#define BCMXCP_METER_MAP_INPUT_VOLTS_BC 4 /* mapped */
#define BCMXCP_METER_MAP_INPUT_VOLTS_CA 5 /* mapped */
#define BCMXCP_METER_MAP_INVERTER_VOLTS_AB 6
#define BCMXCP_METER_MAP_INVERTER_VOLTS_BC 7
#define BCMXCP_METER_MAP_INVERTER_VOLTS_CA 8
#define BCMXCP_METER_MAP_BYPASS_VOLTS_AB 9
#define BCMXCP_METER_MAP_BYPASS_VOLTS_BC 10
#define BCMXCP_METER_MAP_BYPASS_VOLTS_CA 11
#define BCMXCP_METER_MAP_MAIN_LOGIC_POWER 12
#define BCMXCP_METER_MAP_SECONDARY_V_PLUS_POWER 13
#define BCMXCP_METER_MAP_SECONDARY_V_MINUS_POWER 14
#define BCMXCP_METER_MAP_INVERTER_AVG_CURRENT_PHASE_A 15
#define BCMXCP_METER_MAP_INVERTER_AVG_CURRENT_PHASE_B 16
#define BCMXCP_METER_MAP_INVERTER_AVG_CURRENT_PHASE_C 17
#define BCMXCP_METER_MAP_INPUT_CURRENT_PHASE_A 18 /* mapped */
#define BCMXCP_METER_MAP_INPUT_CURRENT_PHASE_B 19 /* mapped */
#define BCMXCP_METER_MAP_INPUT_CURRENT_PHASE_C 20 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_WATTS 21
#define BCMXCP_METER_MAP_INPUT_WATTS 22 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VA 23 /* mapped */
#define BCMXCP_METER_MAP_INPUT_VA 24 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_POWER_FACTOR 25 /* mapped */
#define BCMXCP_METER_MAP_INPUT_POWER_FACTOR 26 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_FREQUENCY 27 /* mapped */
#define BCMXCP_METER_MAP_INPUT_FREQUENCY 28 /* mapped */
#define BCMXCP_METER_MAP_INVERTER_FREQUENCY 29
#define BCMXCP_METER_MAP_BYPASS_FREQUENCY 30 /* mapped */
#define BCMXCP_METER_MAP_DC_LINK_VOLTS_DC 31
#define BCMXCP_METER_MAP_BATTERY_CURRENT 32 /* mapped */
#define BCMXCP_METER_MAP_BATTERY_VOLTAGE 33 /* mapped */
#define BCMXCP_METER_MAP_PERCENT_BATTERY_LEFT 34 /* mapped */
#define BCMXCP_METER_MAP_BATTERY_TIME_REMAINING 35 /* mapped */
#define BCMXCP_METER_MAP_BATTERY_CHARGE_TIME 36
#define BCMXCP_METER_MAP_PEAK_INVERTER_CURRENT_PHASE_A 37
#define BCMXCP_METER_MAP_PEAK_INVERTER_CURRENT_PHASE_B 38
#define BCMXCP_METER_MAP_PEAK_INVERTER_CURRENT_PHASE_C 39
#define BCMXCP_METER_MAP_AVG_INPUT_CURRENT_3_PHASE_SUM 40
#define BCMXCP_METER_MAP_BATTERY_DCUV_BAR_CHART 41 /* mapped */
#define BCMXCP_METER_MAP_INPUT_CURRENT_BAR_CHART 42
#define BCMXCP_METER_MAP_LOW_BATTERY_WARNING_V_BAR_CHART 43 /* mapped */
#define BCMXCP_METER_MAP_DC_VOLTS_BAR_CHART 44
#define BCMXCP_METER_MAP_BATTERY_CHARGING_CURRENT_BAR_CHART 45
#define BCMXCP_METER_MAP_BATTERY_DISCHARGING_CURRENT_BAR_CHART 46 /* mapped */
#define BCMXCP_METER_MAP_PERCENT_LOAD_PHASE_A 47 /* mapped */
#define BCMXCP_METER_MAP_PERCENT_LOAD_PHASE_B 48 /* mapped */
#define BCMXCP_METER_MAP_PERCENT_LOAD_PHASE_C 49 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VA_PHASE_A 50 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VA_PHASE_B 51 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VA_PHASE_C 52 /* mapped */
#define BCMXCP_METER_MAP_BYPASS_VOLTS_PHASE_A 53 /* mapped */
#define BCMXCP_METER_MAP_BYPASS_VOLTS_PHASE_B 54 /* mapped */
#define BCMXCP_METER_MAP_BYPASS_VOLTS_PHASE_C 55 /* mapped */
#define BCMXCP_METER_MAP_INPUT_VOLTS_PHASE_A 56 /* mapped */
#define BCMXCP_METER_MAP_INPUT_VOLTS_PHASE_B 57 /* mapped */
#define BCMXCP_METER_MAP_INPUT_VOLTS_PHASE_C 58 /* mapped */
#define BCMXCP_METER_MAP_INVERTER_VOLTS_PHASE_A 59
#define BCMXCP_METER_MAP_INVERTER_VOLTS_PHASE_B 60
#define BCMXCP_METER_MAP_INVERTER_VOLTS_PHASE_C 61
#define BCMXCP_METER_MAP_AMBIENT_TEMPERATURE 62 /* mapped */
#define BCMXCP_METER_MAP_HEATSINK_TEMPERATURE 63 /* mapped */
#define BCMXCP_METER_MAP_POWER_SUPPLY_TEMPERATURE 64 /* mapped */
#define BCMXCP_METER_MAP_LOAD_CURRENT_PHASE_A 65 /* mapped */
#define BCMXCP_METER_MAP_LOAD_CURRENT_PHASE_B 66 /* mapped */
#define BCMXCP_METER_MAP_LOAD_CURRENT_PHASE_C 67 /* mapped */
#define BCMXCP_METER_MAP_LOAD_CURRENT_PHASE_A_BAR_CHART 68 /* mapped */
#define BCMXCP_METER_MAP_LOAD_CURRENT_PHASE_B_BAR_CHART 69 /* mapped */
#define BCMXCP_METER_MAP_LOAD_CURRENT_PHASE_C_BAR_CHART 70 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VA_BAR_CHART 71 /* mapped */
#define BCMXCP_METER_MAP_DATE 72 /* mapped */
#define BCMXCP_METER_MAP_TIME 73 /* mapped */
#define BCMXCP_METER_MAP_POSITIVE_DC_LINK_RAIL_VOLTAGE 74
#define BCMXCP_METER_MAP_NEGATIVE_DC_LINK_RAIL_VOLTAGE 75
#define BCMXCP_METER_MAP_AUTO_BALANCE_VOLTAGE_DC 76
#define BCMXCP_METER_MAP_BATTERY_TEMPERATURE 77 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VOLTS_A 78 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VOLTS_B 79 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_VOLTS_C 80 /* mapped */
#define BCMXCP_METER_MAP_NEUTRAL_CURRENT 81
#define BCMXCP_METER_MAP_OUTPUT_WATTS_PHASE_A 82 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_WATTS_PHASE_B 83 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_WATTS_PHASE_C 84 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_WATTS_PHASE_A_B_C_BAR_CHART 85 /* mapped */
#define BCMXCP_METER_MAP_RECTIFIER_DC_CURRENT 86
#define BCMXCP_METER_MAP_POSITIVE_BATTERY_VOLTAGE 87
#define BCMXCP_METER_MAP_NEGATIVE_BATTERY_VOLTAGE 88
#define BCMXCP_METER_MAP_POSITIVE_BATTERY_CURRENT 89
#define BCMXCP_METER_MAP_NEGATIVE_BATTERY_CURRENT 90
#define BCMXCP_METER_MAP_LINE_EVENT_COUNTER 91 /* mapped */
#define BCMXCP_METER_MAP_OUTPUT_V1_PERCENT 92
#define BCMXCP_METER_MAP_OUTPUT_V2_PERCENT 93
#define BCMXCP_METER_MAP_OUTPUT_V3_PERCENT 94
#define BCMXCP_METER_MAP_OUTPUT_I1_PERCENT 95
#define BCMXCP_METER_MAP_OUTPUT_I2_PERCENT 96
#define BCMXCP_METER_MAP_OUTPUT_I3_PERCENT 97
#define BCMXCP_METER_MAP_INPUT_V1_PERCENT 98
#define BCMXCP_METER_MAP_INPUT_V2_PERCENT 99
#define BCMXCP_METER_MAP_INPUT_V3_PERCENT 100
#define BCMXCP_METER_MAP_INPUT_I1_PERCENT 101
#define BCMXCP_METER_MAP_INPUT_I2_PERCENT 102
#define BCMXCP_METER_MAP_INPUT_I3_PERCENT 103
#define BCMXCP_METER_MAP_GROUND_CURRENT 104
#define BCMXCP_METER_MAP_OUTPUT_CREST_FACTOR_L1 105
#define BCMXCP_METER_MAP_OUTPUT_CREST_FACTOR_L2 106
#define BCMXCP_METER_MAP_OUTPUT_CREST_FACTOR_L3 107
#define BCMXCP_METER_MAP_OUTPUT_KW_HOUR 108
#define BCMXCP_METER_MAP_INPUT_VOLTAGE_THD_LINE1 109
#define BCMXCP_METER_MAP_INPUT_VOLTAGE_THD_LINE2 110
#define BCMXCP_METER_MAP_INPUT_VOLTAGE_THD_LINE3 111
#define BCMXCP_METER_MAP_INPUT_CURRENT_THD_LINE1 112
#define BCMXCP_METER_MAP_INPUT_CURRENT_THD_LINE2 113
#define BCMXCP_METER_MAP_INPUT_CURRENT_THD_LINE3 114
#define BCMXCP_METER_MAP_OUTPUT_VOLTAGE_THD_LINE1 115
#define BCMXCP_METER_MAP_OUTPUT_VOLTAGE_THD_LINE2 116
#define BCMXCP_METER_MAP_OUTPUT_VOLTAGE_THD_LINE3 117
#define BCMXCP_METER_MAP_OUTPUT_CURRENT_THD_LINE1 118
#define BCMXCP_METER_MAP_OUTPUT_CURRENT_THD_LINE2 119
#define BCMXCP_METER_MAP_OUTPUT_CURRENT_THD_LINE3 120
#define BCMXCP_METER_MAP_INPUT_CREST_FACTOR_L1 121
#define BCMXCP_METER_MAP_INPUT_CREST_FACTOR_L2 122
#define BCMXCP_METER_MAP_INPUT_CREST_FACTOR_L3 123
#define BCMXCP_METER_MAP_INPUT_KW_HOUR 124
#define BCMXCP_METER_MAP_BATTERY_LIFE_REMAINING 125
#define BCMXCP_METER_MAP_SECONDARY_NEUTRAL_CURRENT 126
#define BCMXCP_METER_MAP_SECONDARY_GROUND_CURRENT 127
#define BCMXCP_METER_MAP_HOURS_OF_OPERATION 128
2010-03-25 23:20:59 +00:00
/* Indexes for alarm map */
2013-11-24 15:00:12 +00:00
#define BCMXCP_ALARM_INVERTER_AC_OVER_VOLTAGE 0
#define BCMXCP_ALARM_INVERTER_AC_UNDER_VOLTAGE 1
#define BCMXCP_ALARM_INVERTER_OVER_OR_UNDER_FREQ 2
#define BCMXCP_ALARM_BYPASS_AC_OVER_VOLTAGE 3
#define BCMXCP_ALARM_BYPASS_AC_UNDER_VOLTAGE 4
#define BCMXCP_ALARM_BYPASS_OVER_OR_UNDER_FREQ 5
#define BCMXCP_ALARM_INPUT_AC_OVER_VOLTAGE 6
#define BCMXCP_ALARM_INPUT_AC_UNDER_VOLTAGE 7
#define BCMXCP_ALARM_INPUT_UNDER_OR_OVER_FREQ 8
#define BCMXCP_ALARM_OUTPUT_OVER_VOLTAGE 9
#define BCMXCP_ALARM_OUTPUT_UNDER_VOLTAGE 10
#define BCMXCP_ALARM_OUTPUT_UNDER_OR_OVER_FREQ 11
#define BCMXCP_ALARM_REMOTE_EMERGENCY_PWR_OFF 12
#define BCMXCP_ALARM_REMOTE_GO_TO_BYPASS 13
#define BCMXCP_ALARM_BUILDING_ALARM_6 14
#define BCMXCP_ALARM_BUILDING_ALARM_5 15
#define BCMXCP_ALARM_BUILDING_ALARM_4 16
#define BCMXCP_ALARM_BUILDING_ALARM_3 17
#define BCMXCP_ALARM_BUILDING_ALARM_2 18
#define BCMXCP_ALARM_BUILDING_ALARM_1 19
#define BCMXCP_ALARM_STATIC_SWITCH_OVER_TEMP 20
#define BCMXCP_ALARM_CHARGER_OVER_TEMP 21
#define BCMXCP_ALARM_CHARGER_LOGIC_PWR_FAIL 22
#define BCMXCP_ALARM_CHARGER_OVER_VOLTAGE_OR_CURRENT 23
#define BCMXCP_ALARM_INVERTER_OVER_TEMP 24
#define BCMXCP_ALARM_OUTPUT_OVERLOAD 25
#define BCMXCP_ALARM_RECTIFIER_INPUT_OVER_CURRENT 26
#define BCMXCP_ALARM_INVERTER_OUTPUT_OVER_CURRENT 27
#define BCMXCP_ALARM_DC_LINK_OVER_VOLTAGE 28
#define BCMXCP_ALARM_DC_LINK_UNDER_VOLTAGE 29
#define BCMXCP_ALARM_RECTIFIER_FAILED 30
#define BCMXCP_ALARM_INVERTER_FAULT 31
#define BCMXCP_ALARM_BATTERY_CONNECTOR_FAIL 32
#define BCMXCP_ALARM_BYPASS_BREAKER_FAIL 33
#define BCMXCP_ALARM_CHARGER_FAIL 34
#define BCMXCP_ALARM_RAMP_UP_FAILED 35
#define BCMXCP_ALARM_STATIC_SWITCH_FAILED 36
#define BCMXCP_ALARM_ANALOG_AD_REF_FAIL 37
#define BCMXCP_ALARM_BYPASS_UNCALIBRATED 38
#define BCMXCP_ALARM_RECTIFIER_UNCALIBRATED 39
#define BCMXCP_ALARM_OUTPUT_UNCALIBRATED 40
#define BCMXCP_ALARM_INVERTER_UNCALIBRATED 41
#define BCMXCP_ALARM_DC_VOLT_UNCALIBRATED 42
#define BCMXCP_ALARM_OUTPUT_CURRENT_UNCALIBRATED 43
#define BCMXCP_ALARM_RECTIFIER_CURRENT_UNCALIBRATED 44
#define BCMXCP_ALARM_BATTERY_CURRENT_UNCALIBRATED 45
#define BCMXCP_ALARM_INVERTER_ON_OFF_STAT_FAIL 46
#define BCMXCP_ALARM_BATTERY_CURRENT_LIMIT 47
#define BCMXCP_ALARM_INVERTER_STARTUP_FAIL 48
#define BCMXCP_ALARM_ANALOG_BOARD_AD_STAT_FAIL 49
#define BCMXCP_ALARM_OUTPUT_CURRENT_OVER_100 50
#define BCMXCP_ALARM_BATTERY_GROUND_FAULT 51
#define BCMXCP_ALARM_WAITING_FOR_CHARGER_SYNC 52
#define BCMXCP_ALARM_NV_RAM_FAIL 53
#define BCMXCP_ALARM_ANALOG_BOARD_AD_TIMEOUT 54
#define BCMXCP_ALARM_SHUTDOWN_IMMINENT 55
#define BCMXCP_ALARM_BATTERY_LOW 56
#define BCMXCP_ALARM_UTILITY_FAIL 57
#define BCMXCP_ALARM_OUTPUT_SHORT_CIRCUIT 58
#define BCMXCP_ALARM_UTILITY_NOT_PRESENT 59
#define BCMXCP_ALARM_FULL_TIME_CHARGING 60
#define BCMXCP_ALARM_FAST_BYPASS_COMMAND 61
#define BCMXCP_ALARM_AD_ERROR 62
#define BCMXCP_ALARM_INTERNAL_COM_FAIL 63
#define BCMXCP_ALARM_RECTIFIER_SELFTEST_FAIL 64
#define BCMXCP_ALARM_RECTIFIER_EEPROM_FAIL 65
#define BCMXCP_ALARM_RECTIFIER_EPROM_FAIL 66
#define BCMXCP_ALARM_INPUT_LINE_VOLTAGE_LOSS 67
#define BCMXCP_ALARM_BATTERY_DC_OVER_VOLTAGE 68
#define BCMXCP_ALARM_POWER_SUPPLY_OVER_TEMP 69
#define BCMXCP_ALARM_POWER_SUPPLY_FAIL 70
#define BCMXCP_ALARM_POWER_SUPPLY_5V_FAIL 71
#define BCMXCP_ALARM_POWER_SUPPLY_12V_FAIL 72
#define BCMXCP_ALARM_HEATSINK_OVER_TEMP 73
#define BCMXCP_ALARM_HEATSINK_TEMP_SENSOR_FAIL 74
#define BCMXCP_ALARM_RECTIFIER_CURRENT_OVER_125 75
#define BCMXCP_ALARM_RECTIFIER_FAULT_INTERRUPT_FAIL 76
#define BCMXCP_ALARM_RECTIFIER_POWER_CAPASITOR_FAIL 77
#define BCMXCP_ALARM_INVERTER_PROGRAM_STACK_ERROR 78
#define BCMXCP_ALARM_INVERTER_BOARD_SELFTEST_FAIL 79
#define BCMXCP_ALARM_INVERTER_AD_SELFTEST_FAIL 80
#define BCMXCP_ALARM_INVERTER_RAM_SELFTEST_FAIL 81
#define BCMXCP_ALARM_NV_MEMORY_CHECKSUM_FAIL 82
#define BCMXCP_ALARM_PROGRAM_CHECKSUM_FAIL 83
#define BCMXCP_ALARM_INVERTER_CPU_SELFTEST_FAIL 84
#define BCMXCP_ALARM_NETWORK_NOT_RESPONDING 85
#define BCMXCP_ALARM_FRONT_PANEL_SELFTEST_FAIL 86
#define BCMXCP_ALARM_NODE_EEPROM_VERIFICATION_ERROR 87
#define BCMXCP_ALARM_OUTPUT_AC_OVER_VOLT_TEST_FAIL 88
#define BCMXCP_ALARM_OUTPUT_DC_OVER_VOLTAGE 89
#define BCMXCP_ALARM_INPUT_PHASE_ROTATION_ERROR 90
#define BCMXCP_ALARM_INVERTER_RAMP_UP_TEST_FAILED 91
#define BCMXCP_ALARM_INVERTER_OFF_COMMAND 92
#define BCMXCP_ALARM_INVERTER_ON_COMMAND 93
#define BCMXCP_ALARM_TO_BYPASS_COMMAND 94
#define BCMXCP_ALARM_FROM_BYPASS_COMMAND 95
#define BCMXCP_ALARM_AUTO_MODE_COMMAND 96
#define BCMXCP_ALARM_EMERGENCY_SHUTDOWN_COMMAND 97
#define BCMXCP_ALARM_SETUP_SWITCH_OPEN 98
#define BCMXCP_ALARM_INVERTER_OVER_VOLT_INT 99
#define BCMXCP_ALARM_INVERTER_UNDER_VOLT_INT 100
#define BCMXCP_ALARM_ABSOLUTE_DCOV_ACOV 101
#define BCMXCP_ALARM_PHASE_A_CURRENT_LIMIT 102
#define BCMXCP_ALARM_PHASE_B_CURRENT_LIMIT 103
#define BCMXCP_ALARM_PHASE_C_CURRENT_LIMIT 104
#define BCMXCP_ALARM_BYPASS_NOT_AVAILABLE 105
#define BCMXCP_ALARM_RECTIFIER_BREAKER_OPEN 106
#define BCMXCP_ALARM_BATTERY_CONTACTOR_OPEN 107
#define BCMXCP_ALARM_INVERTER_CONTACTOR_OPEN 108
#define BCMXCP_ALARM_BYPASS_BREAKER_OPEN 109
#define BCMXCP_ALARM_INV_BOARD_ACOV_INT_TEST_FAIL 110
#define BCMXCP_ALARM_INVERTER_OVER_TEMP_TRIP 111
#define BCMXCP_ALARM_INV_BOARD_ACUV_INT_TEST_FAIL 112
#define BCMXCP_ALARM_INVERTER_VOLTAGE_FEEDBACK_ERROR 113
#define BCMXCP_ALARM_DC_UNDER_VOLTAGE_TIMEOUT 114
#define BCMXCP_ALARM_AC_UNDER_VOLTAGE_TIMEOUT 115
#define BCMXCP_ALARM_DC_UNDER_VOLTAGE_WHILE_CHARGE 116
#define BCMXCP_ALARM_INVERTER_VOLTAGE_BIAS_ERROR 117
#define BCMXCP_ALARM_RECTIFIER_PHASE_ROTATION 118
#define BCMXCP_ALARM_BYPASS_PHASER_ROTATION 119
#define BCMXCP_ALARM_SYSTEM_INTERFACE_BOARD_FAIL 120
#define BCMXCP_ALARM_PARALLEL_BOARD_FAIL 121
#define BCMXCP_ALARM_LOST_LOAD_SHARING_PHASE_A 122
#define BCMXCP_ALARM_LOST_LOAD_SHARING_PHASE_B 123
#define BCMXCP_ALARM_LOST_LOAD_SHARING_PHASE_C 124
#define BCMXCP_ALARM_DC_OVER_VOLTAGE_TIMEOUT 125
#define BCMXCP_ALARM_BATTERY_TOTALLY_DISCHARGED 126
#define BCMXCP_ALARM_INVERTER_PHASE_BIAS_ERROR 127
#define BCMXCP_ALARM_INVERTER_VOLTAGE_BIAS_ERROR_2 128
#define BCMXCP_ALARM_DC_LINK_BLEED_COMPLETE 129
#define BCMXCP_ALARM_LARGE_CHARGER_INPUT_CURRENT 130
#define BCMXCP_ALARM_INV_VOLT_TOO_LOW_FOR_RAMP_LEVEL 131
#define BCMXCP_ALARM_LOSS_OF_REDUNDANCY 132
#define BCMXCP_ALARM_LOSS_OF_SYNC_BUS 133
#define BCMXCP_ALARM_RECTIFIER_BREAKER_SHUNT_TRIP 134
#define BCMXCP_ALARM_LOSS_OF_CHARGER_SYNC 135
#define BCMXCP_ALARM_INVERTER_LOW_LEVEL_TEST_TIMEOUT 136
#define BCMXCP_ALARM_OUTPUT_BREAKER_OPEN 137
#define BCMXCP_ALARM_CONTROL_POWER_ON 138
#define BCMXCP_ALARM_INVERTER_ON 139
#define BCMXCP_ALARM_CHARGER_ON 140
#define BCMXCP_ALARM_BYPASS_ON 141
#define BCMXCP_ALARM_BYPASS_POWER_LOSS 142
#define BCMXCP_ALARM_ON_MANUAL_BYPASS 143
#define BCMXCP_ALARM_BYPASS_MANUAL_TURN_OFF 144
#define BCMXCP_ALARM_INVERTER_BLEEDING_DC_LINK_VOLT 145
#define BCMXCP_ALARM_CPU_ISR_ERROR 146
#define BCMXCP_ALARM_SYSTEM_ISR_RESTART 147
#define BCMXCP_ALARM_PARALLEL_DC 148
#define BCMXCP_ALARM_BATTERY_NEEDS_SERVICE 149
#define BCMXCP_ALARM_BATTERY_CHARGING 150
#define BCMXCP_ALARM_BATTERY_NOT_CHARGED 151
#define BCMXCP_ALARM_DISABLED_BATTERY_TIME 152
#define BCMXCP_ALARM_SERIES_7000_ENABLE 153
#define BCMXCP_ALARM_OTHER_UPS_ON 154
#define BCMXCP_ALARM_PARALLEL_INVERTER 155
#define BCMXCP_ALARM_UPS_IN_PARALLEL 156
#define BCMXCP_ALARM_OUTPUT_BREAKER_REALY_FAIL 157
#define BCMXCP_ALARM_CONTROL_POWER_OFF 158
#define BCMXCP_ALARM_LEVEL_2_OVERLOAD_PHASE_A 159
#define BCMXCP_ALARM_LEVEL_2_OVERLOAD_PHASE_B 160
#define BCMXCP_ALARM_LEVEL_2_OVERLOAD_PHASE_C 161
#define BCMXCP_ALARM_LEVEL_3_OVERLOAD_PHASE_A 162
#define BCMXCP_ALARM_LEVEL_3_OVERLOAD_PHASE_B 163
#define BCMXCP_ALARM_LEVEL_3_OVERLOAD_PHASE_C 164
#define BCMXCP_ALARM_LEVEL_4_OVERLOAD_PHASE_A 165
#define BCMXCP_ALARM_LEVEL_4_OVERLOAD_PHASE_B 166
#define BCMXCP_ALARM_LEVEL_4_OVERLOAD_PHASE_C 167
#define BCMXCP_ALARM_UPS_ON_BATTERY 168
#define BCMXCP_ALARM_UPS_ON_BYPASS 169
#define BCMXCP_ALARM_LOAD_DUMPED 170
#define BCMXCP_ALARM_LOAD_ON_INVERTER 171
#define BCMXCP_ALARM_UPS_ON_COMMAND 172
#define BCMXCP_ALARM_UPS_OFF_COMMAND 173
#define BCMXCP_ALARM_LOW_BATTERY_SHUTDOWN 174
#define BCMXCP_ALARM_AUTO_ON_ENABLED 175
#define BCMXCP_ALARM_SOFTWARE_INCOMPABILITY_DETECTED 176
#define BCMXCP_ALARM_INVERTER_TEMP_SENSOR_FAILED 177
#define BCMXCP_ALARM_DC_START_OCCURED 178
#define BCMXCP_ALARM_IN_PARALLEL_OPERATION 179
#define BCMXCP_ALARM_SYNCING_TO_BYPASS 180
#define BCMXCP_ALARM_RAMPING_UPS_UP 181
#define BCMXCP_ALARM_INVERTER_ON_DELAY 182
#define BCMXCP_ALARM_CHARGER_ON_DELAY 183
#define BCMXCP_ALARM_WAITING_FOR_UTIL_INPUT 184
#define BCMXCP_ALARM_CLOSE_BYPASS_BREAKER 185
#define BCMXCP_ALARM_TEMPORARY_BYPASS_OPERATION 186
#define BCMXCP_ALARM_SYNCING_TO_OUTPUT 187
#define BCMXCP_ALARM_BYPASS_FAILURE 188
#define BCMXCP_ALARM_AUTO_OFF_COMMAND_EXECUTED 189
#define BCMXCP_ALARM_AUTO_ON_COMMAND_EXECUTED 190
#define BCMXCP_ALARM_BATTERY_TEST_FAILED 191
#define BCMXCP_ALARM_FUSE_FAIL 192
#define BCMXCP_ALARM_FAN_FAIL 193
#define BCMXCP_ALARM_SITE_WIRING_FAULT 194
#define BCMXCP_ALARM_BACKFEED_CONTACTOR_FAIL 195
#define BCMXCP_ALARM_ON_BUCK 196
#define BCMXCP_ALARM_ON_BOOST 197
#define BCMXCP_ALARM_ON_DOUBLE_BOOST 198
#define BCMXCP_ALARM_BATTERIES_DISCONNECTED 199
#define BCMXCP_ALARM_UPS_CABINET_OVER_TEMP 200
#define BCMXCP_ALARM_TRANSFORMER_OVER_TEMP 201
#define BCMXCP_ALARM_AMBIENT_UNDER_TEMP 202
#define BCMXCP_ALARM_AMBIENT_OVER_TEMP 203
#define BCMXCP_ALARM_CABINET_DOOR_OPEN 204
#define BCMXCP_ALARM_CABINET_DOOR_OPEN_VOLT_PRESENT 205
#define BCMXCP_ALARM_AUTO_SHUTDOWN_PENDING 206
#define BCMXCP_ALARM_TAP_SWITCHING_REALY_PENDING 207
#define BCMXCP_ALARM_UNABLE_TO_CHARGE_BATTERIES 208
#define BCMXCP_ALARM_STARTUP_FAILURE_CHECK_EPO 209
#define BCMXCP_ALARM_AUTOMATIC_STARTUP_PENDING 210
#define BCMXCP_ALARM_MODEM_FAILED 211
#define BCMXCP_ALARM_INCOMING_MODEM_CALL_STARTED 212
#define BCMXCP_ALARM_OUTGOING_MODEM_CALL_STARTED 213
#define BCMXCP_ALARM_MODEM_CONNECTION_ESTABLISHED 214
#define BCMXCP_ALARM_MODEM_CALL_COMPLETED_SUCCESS 215
#define BCMXCP_ALARM_MODEM_CALL_COMPLETED_FAIL 216
#define BCMXCP_ALARM_INPUT_BREAKER_FAIL 217
#define BCMXCP_ALARM_SYSINIT_IN_PROGRESS 218
#define BCMXCP_ALARM_AUTOCALIBRATION_FAIL 219
#define BCMXCP_ALARM_SELECTIVE_TRIP_OF_MODULE 220
#define BCMXCP_ALARM_INVERTER_OUTPUT_FAILURE 221
#define BCMXCP_ALARM_ABNORMAL_OUTPUT_VOLT_AT_STARTUP 222
#define BCMXCP_ALARM_RECTIFIER_OVER_TEMP 223
#define BCMXCP_ALARM_CONFIG_ERROR 224
#define BCMXCP_ALARM_REDUNDANCY_LOSS_DUE_TO_OVERLOAD 225
#define BCMXCP_ALARM_ON_ALTERNATE_AC_SOURCE 226
#define BCMXCP_ALARM_IN_HIGH_EFFICIENCY_MODE 227
#define BCMXCP_ALARM_SYSTEM_NOTICE_ACTIVE 228
#define BCMXCP_ALARM_SYSTEM_ALARM_ACTIVE 229
#define BCMXCP_ALARM_ALTERNATE_POWER_SOURCE_NOT_AVAILABLE 230
#define BCMXCP_ALARM_CURRENT_BALANCE_FAILURE 231
#define BCMXCP_ALARM_CHECK_AIR_FILTER 232
#define BCMXCP_ALARM_SUBSYSTEM_NOTICE_ACTIVE 233
#define BCMXCP_ALARM_SUBSYSTEM_ALARM_ACTIVE 234
#define BCMXCP_ALARM_CHARGER_ON_COMMAND 235
#define BCMXCP_ALARM_CHARGER_OFF_COMMAND 236
#define BCMXCP_ALARM_UPS_NORMAL 237
#define BCMXCP_ALARM_INVERTER_PHASE_ROTATION 238
#define BCMXCP_ALARM_UPS_OFF 239
#define BCMXCP_ALARM_EXTERNAL_COMMUNICATION_FAILURE 240
#define BCMXCP_ALARM_BATTERY_TEST_INPROGRESS 256
#define BCMXCP_ALARM_SYSTEM_TEST_INPROGRESS 257
#define BCMXCP_ALARM_BATTERY_TEST_ABORTED 258
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
#define BCMXCP_COMMAND_MAP_MAX 208 /* Max no of entries in BCM/XCP meter map (adjusted upwards to nearest multi of 8) */
#define BCMXCP_METER_MAP_MAX 136 /* Max no of entries in BCM/XCP meter map (adjusted upwards to nearest multi of 8) */
#define BCMXCP_ALARM_MAP_MAX 264 /* Max no of entries in BCM/XCP alarm map (adjusted upwards to nearest multi of 8) */
/* Return codes for XCP ACK block responses */
#define BCMXCP_RETURN_ACCEPTED 0x31 /* Accepted and executed (or execution in progress) */
#define BCMXCP_RETURN_NOT_IMPLEMENTED 0x32 /* Recognized but not implemented */
#define BCMXCP_RETURN_BUSY 0x33 /* Recognized but not currently able to execute (busy) */
#define BCMXCP_RETURN_UNRECOGNISED 0x34 /* Unrecognized -- e.g., command byte not in valid range, or command has been corrupted (bad checksum) */
#define BCMXCP_RETURN_PARAMETER_OUT_OF_RANGE 0x35 /* Command recognized, but its Parameter value is out of range */
#define BCMXCP_RETURN_INVALID_PARAMETER 0x36 /* Command recognized, but its Parameter is invalid (e.g., no such parameter, bad Outlet number) */
#define BCMXCP_RETURN_ACCEPTED_PARAMETER_ADJUST 0x37 /* Accepted, with parameter adjusted to nearest good value */
/*#define BCMXCP_RETURN_READONLY 0x38 */ /* Parameter is Read-only - cannot be written (at this privilege level) (this is not listed in spec document */
/* UPS status */
#define BCMXCP_STATUS_ONLINE 0x50
#define BCMXCP_STATUS_ONBATTERY 0xf0
#define BCMXCP_STATUS_OVERLOAD 0xe0
#define BCMXCP_STATUS_TRIM 0x63
#define BCMXCP_STATUS_BOOST1 0x61
#define BCMXCP_STATUS_BOOST2 0x62
#define BCMXCP_STATUS_BYPASS 0x60
#define BCMXCP_STATUS_OFF 0x10
/* UPS topology block info */
#define BCMXCP_TOPOLOGY_NONE 0x0000 /* None; use the Table of Elements */
#define BCMXCP_TOPOLOGY_OFFLINE_SWITCHER_1P 0x0010 /* Off-line switcher, Single Phase */
#define BCMXCP_TOPOLOGY_LINEINT_UPS_1P 0x0020 /* Line-Interactive UPS, Single Phase */
#define BCMXCP_TOPOLOGY_LINEINT_UPS_2P 0x0021 /* Line-Interactive UPS, Two Phase */
#define BCMXCP_TOPOLOGY_LINEINT_UPS_3P 0x0022 /* Line-Interactive UPS, Three Phase */
#define BCMXCP_TOPOLOGY_DUAL_AC_ONLINE_UPS_1P 0x0030 /* Dual AC Input, On-Line UPS, Single Phase */
#define BCMXCP_TOPOLOGY_DUAL_AC_ONLINE_UPS_2P 0x0031 /* Dual AC Input, On-Line UPS, Two Phase */
#define BCMXCP_TOPOLOGY_DUAL_AC_ONLINE_UPS_3P 0x0032 /* Dual AC Input, On-Line UPS, Three Phase */
#define BCMXCP_TOPOLOGY_ONLINE_UPS_1P 0x0040 /* On-Line UPS, Single Phase */
#define BCMXCP_TOPOLOGY_ONLINE_UPS_2P 0x0041 /* On-Line UPS, Two Phase */
#define BCMXCP_TOPOLOGY_ONLINE_UPS_3P 0x0042 /* On-Line UPS, Three Phase */
#define BCMXCP_TOPOLOGY_PARA_REDUND_ONLINE_UPS_1P 0x0050 /* Parallel Redundant On-Line UPS, Single Phase */
#define BCMXCP_TOPOLOGY_PARA_REDUND_ONLINE_UPS_2P 0x0051 /* Parallel Redundant On-Line UPS, Two Phase */
#define BCMXCP_TOPOLOGY_PARA_REDUND_ONLINE_UPS_3P 0x0052 /* Parallel Redundant On-Line UPS, Three Phase */
#define BCMXCP_TOPOLOGY_PARA_CAPACITY_ONLINE_UPS_1P 0x0060 /* Parallel for Capacity On-Line UPS, Single Phase */
#define BCMXCP_TOPOLOGY_PARA_CAPACITY_ONLINE_UPS_2P 0x0061 /* Parallel for Capacity On-Line UPS, Two Phase */
#define BCMXCP_TOPOLOGY_PARA_CAPACITY_ONLINE_UPS_3P 0x0062 /* Parallel for Capacity On-Line UPS, Three Phase */
#define BCMXCP_TOPOLOGY_SYSTEM_BYPASS_MODULE_3P 0x0102 /* System Bypass Module, Three Phase */
#define BCMXCP_TOPOLOGY_HOT_TIE_CABINET_3P 0x0122 /* Hot-Tie Cabinet, Three Phase */
#define BCMXCP_TOPOLOGY_OUTLET_CONTROLLER_1P 0x0200 /* Outlet Controller, Single Phase */
#define BCMXCP_TOPOLOGY_DUAL_AC_STATIC_SWITCH_3P 0x0222 /* Dual AC Input Static Switch Module, 3 Phase */
typedef struct { /* Entry in BCM/XCP - UPS mapping table */
const char *command_desc; /* Description of this command */
unsigned char command_byte; /* The command byte for this command, 0 = not supported */
} BCMXCP_COMMAND_MAP_ENTRY_t;
extern BCMXCP_COMMAND_MAP_ENTRY_t bcmxcp_command_map[BCMXCP_COMMAND_MAP_MAX];
2010-03-25 23:20:59 +00:00
typedef struct { /* Entry in BCM/XCP - UPS - NUT mapping table */
2013-11-24 15:00:12 +00:00
const char *nut_entity; /* The NUT variable name */
unsigned char format; /* The format of the data - float, long etc */
unsigned int meter_block_index; /* The position of this meter in the UPS meter block */
} BCMXCP_METER_MAP_ENTRY_t;
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
extern BCMXCP_METER_MAP_ENTRY_t bcmxcp_meter_map[BCMXCP_METER_MAP_MAX];
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
typedef struct { /* Entry in BCM/XCP - UPS mapping table */
int alarm_block_index; /* Index of this alarm in alarm block. -1 = not existing */
const char *alarm_desc; /* Description of this alarm */
} BCMXCP_ALARM_MAP_ENTRY_t;
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
extern BCMXCP_ALARM_MAP_ENTRY_t bcmxcp_alarm_map[BCMXCP_ALARM_MAP_MAX];
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
typedef struct { /* A place to store status info and other data not for NUT */
unsigned char topology_mask; /* Configuration block byte 16, masks valid status bits */
unsigned int lowbatt; /* Seconds of runtime left left when LB alarm is set */
unsigned int shutdowndelay; /* Shutdown delay in seconds, from ups.conf */
int alarm_on_battery; /* On Battery alarm active? */
int alarm_low_battery; /* Battery Low alarm active? */
int alarm_replace_battery; /* Battery needs replacement! */
} BCMXCP_STATUS_t;
2010-03-25 23:20:59 +00:00
2013-11-24 15:00:12 +00:00
extern BCMXCP_STATUS_t bcmxcp_status;
2010-03-25 23:20:59 +00:00
int checksum_test(const unsigned char*);
unsigned char calc_checksum(const unsigned char *buf);
2012-06-01 13:55:19 +00:00
/* from usbhid-ups.h */
typedef struct {
2013-11-24 15:00:12 +00:00
const long xcp_value; /* XCP value */
const char *nut_value; /* NUT value */
const char *(*fun)(double xcp_value); /* optional XCP to NUT mapping */
double (*nuf)(const char *nut_value); /* optional NUT to HID mapping */
2012-06-01 13:55:19 +00:00
} info_lkp_t;
2013-11-24 15:00:12 +00:00
/* use explicit booleans */
#ifndef FALSE
typedef enum ebool { FALSE, TRUE } bool_t;
#else
typedef int bool_t;
#endif
2010-03-25 23:20:59 +00:00
#endif /*_POWERWARE_H */