nut/docs/man/solis.txt

74 lines
1.5 KiB
Text
Raw Permalink Normal View History

2011-01-26 09:35:08 +00:00
SOLIS(8)
========
NAME
----
solis - Driver for Brazilian Microsol SOLIS UPS equipment
NOTE
----
This man page only documents the hardware-specific features of the
solis driver. For information about the core driver, see
linkman:nutupsdrv[8].
SUPPORTED HARDWARE
------------------
2022-06-29 10:37:36 +00:00
This driver has been tested with:
2011-01-26 09:35:08 +00:00
* Solis 1000 VA
* Solis 1500 VA
* Solis 2000 VA
* Solis 3000 VA
2015-04-30 13:53:36 +00:00
* Back-UPS BZ1200-BR
* Back-UPS BZ2200BI-BR
2011-01-26 09:35:08 +00:00
2015-04-30 13:53:36 +00:00
All Solis models are sinusoidal on-line.
In 2009, Schneider Electric acquired Microsol Technologies, and by 2012, the
entire Microsol line of equipment was being sold under the APC brand.
2011-01-26 09:35:08 +00:00
EXTRA ARGUMENTS
---------------
This driver support the following extra optional settings in the
linkman:ups.conf[5].
*battext = n* - (default = 0, no extra battery, where n = Ampere*hour )
2022-06-29 10:37:36 +00:00
*prgshut = 1* - (default = 0, no programmable shutdown )
2011-01-26 09:35:08 +00:00
COMMANDS
--------
* shutdown.return - Shut down in .3 minutes and restart in .3 minutes
* shutdown.stayoff - Shut down in .3 minutes and do not return
2015-04-30 13:53:36 +00:00
ISSUES
------
The APC version of the Microsol protocol is slightly incompatible with the
*solis* driver. As of version 0.62 of the *solis* driver, the driver will
connect to the UPS, but some values are read incorrectly.
2011-01-26 09:35:08 +00:00
AUTHOR
------
2022-06-29 10:37:36 +00:00
2011-01-26 09:35:08 +00:00
Silvino B. Magalhães <sbm2yk@gmail.com>
SEE ALSO
--------
The core driver:
~~~~~~~~~~~~~~~~
2022-06-29 10:37:36 +00:00
2011-01-26 09:35:08 +00:00
linkman:nutupsdrv[8]
Internet resources:
~~~~~~~~~~~~~~~~~~~
2022-06-29 10:37:36 +00:00
2011-01-26 09:35:08 +00:00
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/