nut/docs/man/microsol-apc.8

147 lines
3.5 KiB
Groff
Raw Permalink Normal View History

2022-06-29 10:37:36 +00:00
'\" t
.\" Title: microsol-apc
.\" Author: [see the "AUTHORS" section]
.\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/>
.\" Date: 04/26/2022
.\" Manual: NUT Manual
.\" Source: Network UPS Tools 2.8.0
.\" Language: English
.\"
.TH "MICROSOL\-APC" "8" "04/26/2022" "Network UPS Tools 2\&.8\&.0" "NUT Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
microsol-apc \- Driver for APC Back\-UPS BR UPS equipment
.SH "NOTE"
.sp
This man page only documents the hardware\-specific features of the microsol\-apc driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&.
.SH "SUPPORTED HARDWARE"
.sp
This driver supports the following UPS models:
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
APC Back\-UPS BZ1500\-BR
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
APC Back\-UPS BZ2200I\-BR
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
APC Back\-UPS BZ2200BI\-BR
.RE
.sp
In 2009, Schneider Electric acquired Microsol Technologies, and by 2012, the entire Microsol line was being sold under the APC brand\&. This driver supports these newer, APC\-branded models\&. Older equipment should use \fBsolis\fR(8)\&.
.SH "EXTRA ARGUMENTS"
.sp
This driver support the following extra optional settings in the \fBups.conf\fR(5)\&.
.sp
\fBbattext = n\fR \- (default = 0, no extra battery, where n = Ampere*hour )
.sp
\fBprgshut = 1\fR \- (default = 0, no programmable shutdown )
.SH "COMMANDS"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
shutdown\&.return \- Shut down in \&.3 minutes and restart in \&.3 minutes
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
shutdown\&.stayoff \- Shut down in \&.3 minutes and do not return
.RE
.SH "ISSUES"
.sp
For other APC\-Microsol models, the reported voltages, currents and power will be incorrect, as the communication protocol reports unprocessed data instead of real values, needing model\-specific post\-processing by the driver\&. Monitoring of UPS state (on\-battery/on\-line, critical battery) should work for other models, but is untested\&.
.SH "AUTHORS"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Ygor A\&. S\&. Regados <ygorre@tutanota\&.com>
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Roberto P\&. Velloso <rvelloso@gmail\&.com>
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Silvino B\&. Magalhães <sbm2yk@gmail\&.com>
.RE
.SH "SEE ALSO"
.SS "The core driver:"
.sp
\fBnutupsdrv\fR(8)
.SS "Internet resources:"
.sp
The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/