asem - driver for UPS in ASEM PB1300
|
|
|
|
|
|
|
|
NOTE
|
|
|
|
----
|
2022-06-29 10:37:36 +00:00
|
|
|
|
2015-04-30 13:53:36 +00:00
|
|
|
This man page only documents the hardware-specific features of the
|
|
|
|
*asem* driver. For information about the core driver, see
|
|
|
|
linkman:nutupsdrv[8].
|
|
|
|
|
|
|
|
SUPPORTED HARDWARE
|
|
|
|
------------------
|
2022-06-29 10:37:36 +00:00
|
|
|
|
2015-04-30 13:53:36 +00:00
|
|
|
The *asem* driver supports the UPS in ASEM PB1300 embedded PCs. Likely other
|
|
|
|
I2C devices from the same manufacturer will work too, since this is a "custom"
|
|
|
|
charger.
|
|
|
|
|
|
|
|
Seems that there are two versions of the charger. Older one is based on
|
|
|
|
Max1667, newer one is a custom solution. Both are on I2C address 0x09.
|
|
|
|
To be compatible with both versions, the driver just reads bit 15 of address
|
|
|
|
0x13 which yields online/on battery status.
|
|
|
|
Battery monitor is a BQ2060 at address 0x0B.
|
|
|
|
|
|
|
|
EXTRA ARGUMENTS
|
|
|
|
---------------
|
|
|
|
|
|
|
|
The required parameter for this driver is the I2C bus name:
|
|
|
|
|
|
|
|
*port*='dev-node'::
|
|
|
|
On the Asem PB1300, this should be `/dev/i2c-7` for the i801 SMBUS adapter.
|
|
|
|
|
|
|
|
This driver also supports the following optional settings:
|
|
|
|
|
|
|
|
*lb*='num'::
|
|
|
|
Set the low battery threshold to 'num' volts.
|
2022-06-29 10:37:36 +00:00
|
|
|
|
2015-04-30 13:53:36 +00:00
|
|
|
*hb*='num'::
|
|
|
|
Set the high battery threshold to 'num' volts.
|
|
|
|
|
|
|
|
INSTALLATION
|
|
|
|
------------
|
2022-06-29 10:37:36 +00:00
|
|
|
|
2015-04-30 13:53:36 +00:00
|
|
|
This driver is specific to the Linux I2C API, and requires the lm_sensors
|
|
|
|
libi2c-dev or its equivalent to compile.
|
|
|
|
|
|
|
|
Beware that the SystemIO memory used by the I2C controller is reserved by ACPI.
|
|
|
|
If only a native I2C driver (e.g. i2c_i801, as of 3.5.X Linux kernels) is
|
|
|
|
available, then you'll need to relax the ACPI resources check. For example, you
|
|
|
|
can boot with the `acpi_enforce_resources=lax` option.
|
|
|
|
|
|
|
|
//////////////////////////////////////////
|
|
|
|
Optional: use DIAGNOSTICS to describe troubleshooting techniques that are
|
|
|
|
longer than what can be conveniently described in the driver error messages.
|
|
|
|
|
|
|
|
DIAGNOSTICS
|
|
|
|
-----------
|
|
|
|
|
|
|
|
//////////////////////////////////////////
|
|
|
|
|
|
|
|
KNOWN ISSUES AND BUGS
|
|
|
|
---------------------
|
2022-06-29 10:37:36 +00:00
|
|
|
|
2015-04-30 13:53:36 +00:00
|
|
|
The driver shutdown function is not implemented, so other arrangements must be
|
|
|
|
made to turn off the UPS.
|
|
|
|
|
2022-06-29 10:37:36 +00:00
|
|
|
AUTHOR
|
|
|
|
------
|
|
|
|
|
2015-04-30 13:53:36 +00:00
|
|
|
Giuseppe Corbelli <giuseppe.corbelli@copanitalia.com>
|
|
|
|
|
|
|
|
SEE ALSO
|
|
|
|
--------
|
|
|
|
|
|
|
|
The core driver:
|
|
|
|
~~~~~~~~~~~~~~~~
|
2022-06-29 10:37:36 +00:00
|
|
|
|
2015-04-30 13:53:36 +00:00
|
|
|
linkman:nutupsdrv[8]
|
|
|
|
|
|
|
|
Internet resources:
|
|
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
|
2022-06-29 10:37:36 +00:00
|
|
|
* PB1300 specifications:
|
|
|
|
http://www.asem.it/en/products/industrial-automation/box-pcs/performance/pb1300/
|
|
|
|
* BQ2060 datasheet: http://www.ti.com/lit/ds/symlink/bq2060.pdf
|
|
|
|
* The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|