ASEM(8)
=======
NAME
----
2022-06-29 10:37:36 +00:00
2015-04-30 13:53:36 +00:00
asem - driver for UPS in ASEM PB1300
NOTE
----
2022-06-29 10:37:36 +00:00
2015-04-30 13:53:36 +00:00
This man page only documents the hardware-specific features of the
*asem* driver. For information about the core driver, see
linkman:nutupsdrv[8].
SUPPORTED HARDWARE
------------------
2022-06-29 10:37:36 +00:00
2015-04-30 13:53:36 +00:00
The *asem* driver supports the UPS in ASEM PB1300 embedded PCs. Likely other
I2C devices from the same manufacturer will work too, since this is a "custom"
charger.
Seems that there are two versions of the charger. Older one is based on
Max1667, newer one is a custom solution. Both are on I2C address 0x09.
To be compatible with both versions, the driver just reads bit 15 of address
0x13 which yields online/on battery status.
Battery monitor is a BQ2060 at address 0x0B.
EXTRA ARGUMENTS
---------------
The required parameter for this driver is the I2C bus name:
*port*='dev-node'::
On the Asem PB1300, this should be `/dev/i2c-7` for the i801 SMBUS adapter.
This driver also supports the following optional settings:
*lb*='num'::
Set the low battery threshold to 'num' volts.
2022-06-29 10:37:36 +00:00
2015-04-30 13:53:36 +00:00
*hb*='num'::
Set the high battery threshold to 'num' volts.
INSTALLATION
------------
2022-06-29 10:37:36 +00:00
2015-04-30 13:53:36 +00:00
This driver is specific to the Linux I2C API, and requires the lm_sensors
libi2c-dev or its equivalent to compile.
Beware that the SystemIO memory used by the I2C controller is reserved by ACPI.
If only a native I2C driver (e.g. i2c_i801, as of 3.5.X Linux kernels) is
available, then you'll need to relax the ACPI resources check. For example, you
can boot with the `acpi_enforce_resources=lax` option.
//////////////////////////////////////////
Optional: use DIAGNOSTICS to describe troubleshooting techniques that are
longer than what can be conveniently described in the driver error messages.
DIAGNOSTICS
-----------
//////////////////////////////////////////
KNOWN ISSUES AND BUGS
---------------------
2022-06-29 10:37:36 +00:00
2015-04-30 13:53:36 +00:00
The driver shutdown function is not implemented, so other arrangements must be
made to turn off the UPS.
2022-06-29 10:37:36 +00:00
AUTHOR
------
2015-04-30 13:53:36 +00:00
Giuseppe Corbelli <giuseppe.corbelli@copanitalia.com>
SEE ALSO
--------
The core driver:
~~~~~~~~~~~~~~~~
2022-06-29 10:37:36 +00:00
2015-04-30 13:53:36 +00:00
linkman:nutupsdrv[8]
Internet resources:
~~~~~~~~~~~~~~~~~~~
2022-06-29 10:37:36 +00:00
* PB1300 specifications:
http://www.asem.it/en/products/industrial-automation/box-pcs/performance/pb1300/
* BQ2060 datasheet: http://www.ti.com/lit/ds/symlink/bq2060.pdf
* The NUT (Network UPS Tools) home page: http://www.networkupstools.org/