The create-network form only checked the characters of its subnets, so 192.0.2.0/33 or 999.0.2.0/24 passed and network_size raised a ValueError: the user got a server error instead of a message. So did a subnet too small for the gateway, DHCP range and broadcast address that network_size derives (0.0.0.0/32, 255.255.255.255/32), and 192.0.2.0/31 or a bare address gave an inverted DHCP range. Each subnet field now parses its value as a network of its IP version and refuses it with a field error otherwise. An IPv4 prefix must be /30 or shorter; the IPv6 prefix must be /64, which the view checked after the form and now the form does. |
||
|---|---|---|
| .. | ||
| __init__.py | ||
| test_add_net_pool_form.py | ||
| test_fixed_address_form.py | ||