catborise
d37aa42392 feat(console): a working serial console
The xterm console never connected: socketiod expected a different token
format, its worker had no compute credentials, one global console was
shared by every client and its output broadcast to all of them, and the
Docker image did not run socketiod at all.

- console/tokens.py: one authorize() for noVNC and socketiod; the signed
  token is the only credential, checked at connect time.
- socketiod: one pty worker per client (consolecallback with the
  instance id), one session per VM, a session cap, input and resize
  checked; the parent never opens libvirt. The engine.io same-origin
  check is on.
- consolecallback: opens the console with the compute's credentials and
  exits with a message when it cannot.
- Docker runs socketiod as a runit service; nginx proxies /socket.io/
  with Host and the scheme for the origin check. Supervisor and systemd
  start it as well; WEBVIRTCLOUD_SERIAL_CONSOLE=1 enables it.
- Tests: token and session unit tests, socketiod as a process, and a
  live test that reads SeaBIOS from a wvc-test VM on the TCP and SSH
  hosts.
2026-10-17 19:43:09 +03:00
catborise
b59f30138a build: run the job worker in every install type 2026-10-14 23:27:57 +03:00
catborise
1547e58e55 fix(console): disable the unauthenticated serial console by default
socketiod does not validate the console token, keeps a single global PTY
and broadcasts its output to every connected client, so anyone who can
reach port 6081 can read and write a serial console that someone opened.
It is also broken for legitimate users, since console/views.py now writes
signed tokens that socketiod cannot parse.

Until it is rewritten, turn the serial console off by default:

- Add SERIAL_CONSOLE_ENABLED = False to the settings template; installs
  whose settings.py lacks it are treated as disabled.
- The console view shows an error instead of the xterm page for pty
  consoles while the setting is off.
- socketiod refuses to start unless SERIAL_CONSOLE_ENABLED is True.
- Supervisor: autostart=false for socketiod; drop -d (debug) from the
  supervisor and systemd definitions; fix the systemd unit description;
  conf/systemd/install.sh no longer suggests enabling socketiod.
- README: stop opening port 6081 and document how to enable the serial
  console on a trusted network.
2026-10-02 17:22:20 +03:00
Gaëtan Ferez
65dce10ce1 Implement Libvirt Serial Console as Console on WebVirtCloud 2022-07-17 13:25:47 +02:00
catborise
4d40de1b55 Python3 & Django 2.2 Migration - Fix & Updates 2020-03-16 16:59:45 +03:00
Retspen
13e5d70ff3 Moved all to virtualenv 2015-06-16 08:49:30 +03:00
Retspen
868dda5494 Cleaned some places 2015-04-21 17:13:53 +03:00
Retspen
8e8f300668 Added production files 2015-03-27 16:20:30 +02:00