ccs811_one_sensor | ||
ccs811_plus_sht3x | ||
ccs811_temperature | ||
README.md |
CCS811 Driver Examples
These examples demonstrate the usage of the CCS811 driver with only one sensors.
Hardware setup
Most examples use only one CCS811 sensor. Following figure shows the hardware configuration if no interrupt is used.
+------------------------+ +--------+
| ESP8266 Bus 0 | | CCS811 |
| GPIO 5 (SCL) -----> SCL |
| GPIO 4 (SDA) <----> SDA |
| GND -----> /WAKE |
+------------------------+ +--------+
If nINT interrupt is used to fetch new data, additionally the interrupt pin has to be connected to a GPIO pin.
+------------------------+ +--------+
| ESP8266 Bus 0 | | CCS811 |
| GPIO 5 (SCL) -----> SCL |
| GPIO 4 (SDA) <----> SDA |
| GPIO 2 <----- /nINT |
| GND -----> /WAKE |
+------------------------+ +--------+
In examples where CCS811 sensor is used in conjunction with a SHT3x sensor, the hardware configuration looks like following:
+------------------------+ +--------+
| ESP8266 Bus 0 | | CCS811 |
| GPIO 5 (SCL) ---+----> SCL |
| GPIO 4 (SDA) <--|-+--> SDA |
| GND ---|-|--> /WAKE |
| | | | +--------+
| | | | | SHT3x |
| | +----> SCL |
| | +--> SDA |
+------------------------+ +--------+
Example description
ccs811_one_sensor
Simple example with one CCS811 sensor connected to I2C bus 0. It demonstrates the different approaches to fetch the data. Either the interrupt nINT is used when new data are available or exceed defined thresholds or the new data are fetched periodically. Which approach is used is defined by the constants INT_DATA_RDY_USED
and INT_THRESHOLD_USED
.
ccs811_plus_sht3x
Simple example with one CCS811 sensor connected to I2C bus 0 and one SHT3x sensor to determine ambient temperature. New data are fetched peridically every 2 seconds.
ccs811_temperature
Simple example with one CCS811 sensor connected to I2C bus 0. It demonstrates how to use CCS811 with an external NTC resistor to determine ambient temperature.