0d9094e443
* bmp280 more options add option to user for temp oversampling and possibility to skipp a specific measure * Update bmp280.h * quick fix oups * less redundant terms
197 lines
5.8 KiB
C
197 lines
5.8 KiB
C
/**
|
|
* The MIT License (MIT)
|
|
*
|
|
* Copyright (c) 2016 sheinz (https://github.com/sheinz)
|
|
*
|
|
* Permission is hereby granted, free of charge, to any person obtaining a copy
|
|
* of this software and associated documentation files (the "Software"), to deal
|
|
* in the Software without restriction, including without limitation the rights
|
|
* to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
|
|
* copies of the Software, and to permit persons to whom the Software is
|
|
* furnished to do so, subject to the following conditions:
|
|
*
|
|
* The above copyright notice and this permission notice shall be included in
|
|
* all copies or substantial portions of the Software.
|
|
*
|
|
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
|
|
* IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
|
|
* FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
|
|
* AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
|
|
* LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
|
|
* OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN
|
|
* THE SOFTWARE.
|
|
*/
|
|
#ifndef __BMP280_H__
|
|
#define __BMP280_H__
|
|
|
|
#include <stdint.h>
|
|
#include <stdbool.h>
|
|
|
|
#ifdef __cplusplus
|
|
extern "C" {
|
|
#endif
|
|
|
|
/**
|
|
* Uncomment to enable debug output.
|
|
*/
|
|
// #define BMP280_DEBUG
|
|
|
|
/**
|
|
* BMP280 or BME280 address is 0x77 if SDO pin is high, and is 0x76 if
|
|
* SDO pin is low.
|
|
*/
|
|
#define BMP280_I2C_ADDRESS_0 0x76
|
|
#define BMP280_I2C_ADDRESS_1 0x77
|
|
|
|
#define BMP280_CHIP_ID 0x58 /* BMP280 has chip-id 0x58 */
|
|
#define BME280_CHIP_ID 0x60 /* BME280 has chip-id 0x60 */
|
|
|
|
/**
|
|
* Mode of BMP280 module operation.
|
|
* Forced - Measurement is initiated by user.
|
|
* Normal - Continues measurement.
|
|
*/
|
|
typedef enum {
|
|
BMP280_MODE_SLEEP = 0,
|
|
BMP280_MODE_FORCED = 1,
|
|
BMP280_MODE_NORMAL = 3
|
|
} BMP280_Mode;
|
|
|
|
typedef enum {
|
|
BMP280_FILTER_OFF = 0,
|
|
BMP280_FILTER_2 = 1,
|
|
BMP280_FILTER_4 = 2,
|
|
BMP280_FILTER_8 = 3,
|
|
BMP280_FILTER_16 = 4
|
|
} BMP280_Filter;
|
|
|
|
/**
|
|
* Pressure oversampling settings
|
|
*/
|
|
typedef enum {
|
|
BMP280_SKIPPED = 0, /* no measurement */
|
|
BMP280_ULTRA_LOW_POWER = 1, /* oversampling x1 */
|
|
BMP280_LOW_POWER = 2, /* oversampling x2 */
|
|
BMP280_STANDARD = 3, /* oversampling x4 */
|
|
BMP280_HIGH_RES = 4, /* oversampling x8 */
|
|
BMP280_ULTRA_HIGH_RES = 5 /* oversampling x16 */
|
|
} BMP280_Oversampling;
|
|
|
|
/**
|
|
* Stand by time between measurements in normal mode
|
|
*/
|
|
typedef enum {
|
|
BMP280_STANDBY_05 = 0, /* stand by time 0.5ms */
|
|
BMP280_STANDBY_62 = 1, /* stand by time 62.5ms */
|
|
BMP280_STANDBY_125 = 2, /* stand by time 125ms */
|
|
BMP280_STANDBY_250 = 3, /* stand by time 250ms */
|
|
BMP280_STANDBY_500 = 4, /* stand by time 500ms */
|
|
BMP280_STANDBY_1000 = 5, /* stand by time 1s */
|
|
BMP280_STANDBY_2000 = 6, /* stand by time 2s BMP280, 10ms BME280 */
|
|
BMP280_STANDBY_4000 = 7, /* stand by time 4s BMP280, 20ms BME280 */
|
|
} BMP280_StandbyTime;
|
|
|
|
/**
|
|
* Configuration parameters for BMP280 module.
|
|
* Use function bmp280_init_default_params to use default configuration.
|
|
*/
|
|
typedef struct {
|
|
BMP280_Mode mode;
|
|
BMP280_Filter filter;
|
|
BMP280_Oversampling oversampling_pressure;
|
|
BMP280_Oversampling oversampling_temperature;
|
|
BMP280_Oversampling oversampling_humidity;
|
|
BMP280_StandbyTime standby;
|
|
} bmp280_params_t;
|
|
|
|
|
|
typedef struct {
|
|
uint16_t dig_T1;
|
|
int16_t dig_T2;
|
|
int16_t dig_T3;
|
|
uint16_t dig_P1;
|
|
int16_t dig_P2;
|
|
int16_t dig_P3;
|
|
int16_t dig_P4;
|
|
int16_t dig_P5;
|
|
int16_t dig_P6;
|
|
int16_t dig_P7;
|
|
int16_t dig_P8;
|
|
int16_t dig_P9;
|
|
|
|
/* Humidity compensation for BME280 */
|
|
uint8_t dig_H1;
|
|
int16_t dig_H2;
|
|
uint8_t dig_H3;
|
|
int16_t dig_H4;
|
|
int16_t dig_H5;
|
|
int8_t dig_H6;
|
|
|
|
uint8_t i2c_addr; /* I2C address. */
|
|
uint8_t id; /* Chip ID */
|
|
} bmp280_t;
|
|
|
|
/**
|
|
* Initialize default parameters.
|
|
* Default configuration:
|
|
* mode: NORAML
|
|
* filter: OFF
|
|
* oversampling: x4
|
|
* standby time: 250ms
|
|
*/
|
|
void bmp280_init_default_params(bmp280_params_t *params);
|
|
|
|
/**
|
|
* Initialize BMP280 module, probes for the device, soft resets the device,
|
|
* reads the calibration constants, and configures the device using the supplied
|
|
* parameters. Returns true on success otherwise false.
|
|
*
|
|
* The I2C address is assumed to have been initialized in the dev, and
|
|
* may be either BMP280_I2C_ADDRESS_0 or BMP280_I2C_ADDRESS_1. If the I2C
|
|
* address is unknown then try initializing each in turn.
|
|
*
|
|
* This may be called again to soft reset the device and initialize it again.
|
|
*/
|
|
bool bmp280_init(bmp280_t *dev, bmp280_params_t *params);
|
|
|
|
/**
|
|
* Start measurement in forced mode.
|
|
* The module remains in forced mode after this call.
|
|
* Do not call this method in normal mode.
|
|
*/
|
|
bool bmp280_force_measurement(bmp280_t *dev);
|
|
|
|
/**
|
|
* Check if BMP280 is busy with measuring temperature/pressure.
|
|
* Return true if BMP280 is busy.
|
|
*/
|
|
bool bmp280_is_measuring(bmp280_t *dev);
|
|
|
|
/**
|
|
* Read compensated temperature and pressure data:
|
|
*
|
|
* Temperature in degrees Celsius times 100.
|
|
*
|
|
* Pressure in Pascals in fixed point 24 bit integer 8 bit fraction format.
|
|
*
|
|
* Humidity is optional and only read for the BME280, in percent relative
|
|
* humidity as a fixed point 22 bit interger and 10 bit fraction format.
|
|
*/
|
|
bool bmp280_read_fixed(bmp280_t *dev, int32_t *temperature,
|
|
uint32_t *pressure, uint32_t *humidity);
|
|
|
|
/**
|
|
* Read compensated temperature and pressure data:
|
|
* Temperature in degrees Celsius.
|
|
* Pressure in Pascals.
|
|
* Humidity is optional and only read for the BME280, in percent relative
|
|
* humidity.
|
|
*/
|
|
bool bmp280_read_float(bmp280_t *dev, float *temperature,
|
|
float *pressure, float *humidity);
|
|
|
|
#ifdef __cplusplus
|
|
}
|
|
#endif
|
|
|
|
#endif // __BMP280_H__
|