esp-open-rtos/examples/ota_basic/ota_basic.def
Angus Gratton 147257efa4 Almost functional OTA support
ota_basic example can receive new image via TCP.

However - writing to flash with interrupts disabled causes data loss,
and the TCP flow is very slow to recover. Linux sender quickly ramps up
RTT timer to very long retry intervals, crippling performance &
throughput.

Running the update without the flash writes causes the data to be
received quickly, so this is definitely an issue with the time taken for
the erase cycle.

Progress towards #10
2015-07-29 16:50:23 +10:00

9 lines
172 B
Modula-2

cpu xtensa
# Show up to this many raw bytes of code/data
show bytes 4
# ELF file
# See example.def if you want to load raw binaries instead
load build/ota_basic.out elf