Fix SDIO send_command
This patch fixes the problem, while receiving R1b type of response from the card. In case of R1b response the continuous stream that the card sends must be checked whether the signal indicates busy status and wait until a non zero response.
This commit is contained in:
parent
4581999feb
commit
3b5510dce1
1 changed files with 19 additions and 4 deletions
|
@ -182,10 +182,6 @@ static uint8_t command(sdio_card_t *card, uint8_t cmd, uint32_t arg)
|
|||
wait();
|
||||
spi_transfer(BUS, buf, NULL, 6, SPI_8BIT);
|
||||
|
||||
// R1b response
|
||||
if (cmd == CMD12 || cmd == CMD28 || cmd == CMD29)
|
||||
spi_read_byte();
|
||||
|
||||
uint8_t res;
|
||||
for (uint8_t i = 0; i < MAX_ERR_COUNT; i ++)
|
||||
{
|
||||
|
@ -193,6 +189,25 @@ static uint8_t command(sdio_card_t *card, uint8_t cmd, uint32_t arg)
|
|||
if (!(res & BV(R1_BUSY)))
|
||||
break;
|
||||
}
|
||||
|
||||
/** If the response is a "busy" type (R1B), then there’s some
|
||||
* special handling that needs to be done. The card will
|
||||
* output a continuous stream of zeros, so the end of the BUSY
|
||||
* state is signaled by any nonzero response.
|
||||
*/
|
||||
if (cmd == CMD12 || cmd == CMD28 || cmd == CMD29)
|
||||
{
|
||||
for (uint8_t i = 0; i < MAX_ERR_COUNT; i ++)
|
||||
{
|
||||
res = spi_read_byte();
|
||||
if (res != 0)
|
||||
{
|
||||
spi_transfer_8(BUS, 0xFF);
|
||||
return SDIO_ERR_NONE;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
return res;
|
||||
}
|
||||
|
||||
|
|
Loading…
Reference in a new issue